Furuno GP-7000F Calibrating Nmea Depth, Speed and Water Temperature Data, EXT Nmea menu

Page 39

3.5Calibrating NMEA Depth, Speed and Water Temperature Data

NMEA speed, depth and water temperature data may be corrected from the GP-7000F if they can- not be done from the equipment that outputs the data. Enter a minus value if the actual value is lower than the NMEA data, or a plus value if the actual value is higher than the NMEA data. For example, if the actual water temperature is 20° and the water temperature data output by the sen- sor is 17°, enter +3(°).

1.Press the [MENU] key to show the menu bar.

2.Rotate the [ENTER] knob to choose ADVANCED from the menu bar and then push the [ENTER] knob.

3.Rotate the [ENTER] knob to choose EXT NMEA and then push the [ENTER] knob.

 

 

 

 

 

DRAFT SETUP

+00.0 Ft

 

 

SPEED CALIBRATION +00 %

 

TEMP CALIBRATION

+00.00°F

 

 

 

 

EXT NMEA menu

4.Rotate the [ENTER] knob to choose appropriate item.

DRAFT SETUP: Enter ship's draft to get NMEA depth from sea surface (instead of trans- ducer). To get depth from hull bottom, measure distance between bottom of transducer and hull bottom and enter that value with a minus.

SPEED CALIBRATION: Find correct speed from known source and enter offset to correct NMEA speed indication.

TEMP CALIBRATION: Find correct water temperature from known source and enter offset to correct NMEA water temperature indication.

5.Push the [ENTER] knob. The cursor is selecting the plus sign (or minus sign). If it is necessary to switch from plus to minus or vice versa, rotate the [ENTER] knob to choose plus or minus and then push the [ENTER] knob. If not necessary, go to step 6.

6.Push the [ENTER] knob, rotate the [ENTER] knob to set digit and then push the [ENTER] knob. To clear a line of data, press the [CLR FLD] soft key, which is the third key from the left of the keys below the screen.

Setting range

Draft setup: -20 - +39.9 (ft)

Speed calibration: -50 - +50 (%)

Temp calibration: -50 - +50 (°F)

7.Set other digits as you did in step 6.

8.Press the [SAVE] soft key, which is the fourth key from the left of the keys below the screen.

9.If necessary, repeat step 4-8 to choose and set another calibration item.

10.Press the [MENU] key to close all open windows and erase the menu bar.

33

Image 39
Contents Iii Color GPS/PLOTTER/SOUNDER GP-7000F00014914012 Safety Instructions System Configuration Name Type Code No Qty Remarks Standard supplyName Type Code No Qty Optional equipmentMounting considerations Display UnitDesktop, overhead mounting MountingFlush mounting Antenna Unit Necessary tools Remarks on installationTransducer Inside-hull mountingSqueezing out air bubbles in adhesive Attaching the transducerFinal preparations Coating transducer face with silicone sealantThru-hull mount transducer mounting dimensions millimeters Thru-hull mountingTransducer mounting location Suitable transducer mounting locations Acceptable transducer mounting locationsProcedure for installing the thru-hull mount transducer Construction of fairing blockTransducer mounting Transom mount transducer Installing the transom mount transducer on a flat hullTransducer preparation Installing the transom mount transducer on a deep-V hullTriducer 525ST-MSD Optional triducerMounting location on single drive boat Height required at mounting locationInstallation template Sensor position and transom angle Attaching the sensor to the bracket Vertical adjustment and cable routingPage Speed/water temperature sensor ST-02MSB, ST-02PSB Optional Speed/Water Temperature Sensor ST-02MSB, ST-02PSBWiring Transducer Power sourceGround Types of antenna cables Connecting the antenna cableAntenna Code no Contents Cable set Antenna cableWaterproofing the connector How to attach N-P-8DFB connector for extension cable kit Optional transducer Fabricating the transducer cablePart Type Code No Qty Remarks Choosing Position Data Source AdjustmentsINPUT/OUTPUT menu Description of Nmea options Choosing Port I/O FormatNmea 1 INPUT, Nmea 1 Output menus InputPort Format Data sentence Remarks OutputFormat Input data, sentence priorityEcho Sounder System Setup menu Echo Sounder SettingsSetting transducer model, output power Output Power TransducerCalibrating speed/water temperature sensor, setting draft Sensor Setup menuEcho Sounder menu Choosing Data Sources Setting rangeCalibrating Nmea Depth, Speed and Water Temperature Data Setting rangeEXT Nmea menu External Event Format Waypoint, Route FormatPrimary, Secondary Unit C-link Packing List GP-7000/F-E-C-017,GP-7000/F-E-N-017 Packing List GP-7000/F-E-C,GP-7000/F-E-N Page Page Hatai Mar,2707 R.Esumi Feb Page Page Page 指示部 Display Unit GP-7000F