Installation Instructions
Final Assembly and Test (cont.)
LP Cylinder Installation - Some Models
warning
•The largest recommended LP cylinder size for the rollout tank shelf on the cart is five gallons. A five gallon portable liquid propane cylinder should be approximately 12 inches (305mm) in diameter and
18 inches (457mm) high,. It must be constructed and marked in accordance with the specification for liquid propane (LP) gas cylinders of the U.S. Department of Transportation (DOT) and designed for use with a
•Cylinders must be stored outdoors in a well vented area out of the reach of children.
•On installations with a LP cylinder, when storing the appliance indoors, you must disconnect and store the LP cylinder outdoors.
•On models OB52 and OBS52 equipped for use with a LP tank, use only a two stage regulator on the gas supply line.
•For LP cylinder installations, the LP gas cylinder must have its own certified
•A dented or rusty LP tank may be hazardous and should be checked by your LP supplier.
•Never use a cylinder with a damaged
•Do not change the regulator/hose assembly with a standard 510 POL tank/valve assembly.
•The cylinder must be provided with a
•The cylinder supply system must be arranged for vapor withdrawal and provided with a listed overfilling prevention device.
1.For units that will use a LP cylinder, start by making sure the tank
2.Place the tank into the final position within the cabinet or cart.
| Gas connection at |
| right rear corner |
| under outdoor grill |
| Tank gas |
| regulator (included) |
| LP tank valve |
Slideout LP tank | Flexible gas |
storage shelf on | line (included) |
optional cart |
|
| LP tank |
| (not included) |
| 5 Gallon maximum |
| shelf capacity |
Leak Testing
warning
•Do not use a flame to check leaks.
•The grill or cooktop and
1.Turn all burner control knobs on the front of the appliance to the OFF position.
2.With the power to the appliance DISCONNECTED, open the gas
valve.OFF
3.Check all gas connections for leaks using an electronic gas leak detector. You may also apply a water and soap solution to the connections. Bubbles around the connections indicate a leak. If you observe leakage do not attempt to operate the appliance until all leaks have been eliminated.
Power Connection - Cart Models
1.If the appliance is installed on a cart, connect a three- prong extension cord (minimum 5 Amp. capacity) designed for outdoor use to the power input on the back of the cart. Connect the other end of the exten- sion cord to a grounded,