Desa (V)T36NA installation manual What to do if YOU Smell GAS

Page 1

DIRECT-VENT FIREPLACE

OWNER’S OPERATION AND INSTALLATION MANUAL

NATURAL GAS “TUDOR” MODELs (V)T36NA SERIES

and CTDV36NRA

PROPANE/LP GAS “TUDOR” MODELs (V)T36PA SERIES

WARNING: If the information in this manual is not fol- lowed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a quali- fied installer, service agency or the gas supplier.

INSTALLER: Leave this manual with the appliance

CONSUMER: Retain this manual for future reference.

For more information, visit www.desatech.com

Image 1
Contents What to do if YOU Smell GAS Safety Information Table of ContentsSafety Information Local Codes Product FeaturesProduct Identification High traffic areasLocation and space requirements Pre-Installation PreparationThis fireplace does not require electricity to operate Proper clearances must be maintainedFraming and finishing ClearancesFront Top of Standoffs Vent See venting Venting clearancesBalcony with Perpendicular Side Wall Location of Termination CapInstallation Precautions Venting Installation InstructionsInstallation Planning Installing Horizontal Vent Cap Noncombustible Exterior 32 min Ground Floor InstallationRecommended Applications Corner ground floor installation Snorkel Termination InstallationHorizontal System Installation Using TWO 90 Elbows Flat Ceiling Installation Installation for vertical terminationConnect a section of pipe and extend up through the hole Twist-lock the vent cap onto the last section of vent pipe Vertical Venting High Altitude InstallationDesa Elbows Desa Venting AccessoriesDesa Terminations Number DescriptionInstalling optional blower accessories Fireplace InstallationModel BK Installation Check GAS TypePlug in blower power cord to duplex outlet Model BKT InstallationBlower Wiring Diagram Installing Gas Piping to Fireplace LocationInstallation Items Needed Checking GAS Connections Connecting Fireplace to GAS SupplyTest Pressures Equal To or Less Than Psig 3.5 kPa Pressure Testing Fireplace Gas ConnectionsInstalling Remote Receiver Installing optional wall mount switch GWMS2Open bottom louver and locate the switch Removing/Replacing Glass Door Cleaning Glass DoorRemoving Louver Panels Removing Glass DoorClose top and bottom louvers Installing logs, lava rock and glowing embersInstalling Log No Operating Fireplace For your safety Read before lightingLighting Instructions To Turn OFF GAS To ApplianceOptional Hand-Held Manual Lighting ProcedureOn/Off Series Models HRC100 and HRC101 Remote OperationSafety Features Operating optional blower accessoryAuto Shutoff Feature Operating optional GWMT1 Wall Mounted ThermostatPilot Assembly Cleaning MaintenanceInspecting Burners Burner Flame PatternLogs Pilot and burnersVenting system Observed Problem Possible Cause Remedy TroubleshootingProblem could be caused by Replace pilot assembly Mocouple to cool, causingBurner orifice clogged Clean burner see Cleaning Is lit After pilot lights, keep gasDirty or partially clogged 3. Clean burner see Cleaning When burner is litOr shut off Service person Remote does not function Tery power is lowStatement above Gas leak. See WarningService Hints Replacement PartsTechnical Service SpecificationsFace/Louver Panel kit Wall mounted on/off switch gwms2 Not ShownRolled Louver Trim kit Deflection hoodIllustrated Parts Breakdown Left Refractory Brick Panel Rear Refractory Brick PanelIllustrated Parts Breakdown 11102 111250-01E 111250-01E Keep this Warranty Warranty InformationLimited Warranty DIRECT-VENT Fireplace

(V)T36NA specifications

Desa (V)T36NA is an advanced piece of machinery designed primarily for heavy-duty applications in various industrial sectors. Known for its reliability and efficiency, this model has gained popularity among operators seeking high performance without compromising on durability.

One of the standout features of the Desa (V)T36NA is its powerful engine. It is equipped with a state-of-the-art internal combustion engine that provides robust torque and horsepower, enabling it to tackle demanding tasks with ease. This power is complemented by a highly efficient fuel system that minimizes consumption, making it both cost-effective and environmentally friendly.

The Desa (V)T36NA incorporates cutting-edge technologies that enhance its operational capabilities. Its intelligent control system allows for seamless adjustments to power settings based on task requirements. This feature not only improves performance but also extends the lifespan of the machinery by preventing overexertion. Additionally, the unit is integrated with advanced diagnostic tools that monitor performance metrics, enabling operators to identify issues before they escalate.

Another notable characteristic of the Desa (V)T36NA is its robust construction. Built from high-grade materials, this machinery is designed to withstand the rigors of tough industrial environments. The frame is reinforced to handle heavy loads and resist wear and tear, which significantly reduces maintenance costs over time.

In terms of ergonomics, the machinery is designed with user comfort in mind. The operator's cabin is spacious, providing ample room and visibility for enhanced maneuverability. The controls are intuitively laid out, ensuring that operators can make adjustments quickly and efficiently.

The Desa (V)T36NA also emphasizes safety, featuring advanced safety mechanisms such as automatic braking systems and secure cabin enclosures. These features protect both the operator and the surrounding personnel, making it a reliable choice for any workspace.

Overall, the Desa (V)T36NA represents a significant advancement in heavy machinery, combining power, efficiency, and safety in one robust package. Its innovative technologies and solid construction make it an excellent investment for industries seeking to enhance productivity while ensuring operator comfort and safety. Whether in construction, manufacturing, or other heavy-duty applications, the Desa (V)T36NA stands out as a trustworthy ally in achieving operational goals.