Inspecting Burners

Check pilot flame pattern and burner flame pat- terns often.

PILOT Assembly

The pilot assembly is factory preset for the proper flame. Alterations may have occurred during ship- ping and handling. The pilot is located on the back right hand side of the burner.

The flame must envelope 1/4" of top of the ignitor/ sensor and grounding stem.

If your pilot assembly does not meet these re- quirements:

Turn the adjustment screw marked PILOT clock- wise to decrease or counterclockwise to increase the flame to proper size (see Figure 54). Do not remove the adjustment screw.

see Troubleshooting, page 32

Thermopile

3/8" to 1/2" Pilot Burner

1/8"

Piezo Thermocouple Ignitor

Figure 54 - Pilot Assembly

BURNER FLAME PATTERN

Burner flames will be steady; not lifting or floating. Flame patterns will be different from unit to unit and will vary depending on installation type and weather conditions.

If the vent configuration is installed incorrectly, the flames will lift or "ghost". This can be danger- ous. Inspect the flames after installation to ensure proper installation and performance.

Figure 55 shows a typical flame pattern.

If burner flame pattern differs from that described:

turn fireplace off (see To Turn Off Gas to Ap- pliance, page 27)

see Troubleshooting, page 32

Figure 55 - Typical Flame Pattern

Cleaning and

Maintenance

WARNING: Turn off fireplace and let cool before cleaning.

CAUTION: You must keep control areas, burners, and circulating air passageways of fireplace clean. Inspect these areas of fireplace before each use. Have fireplace inspected yearly by a qualified service person. Fireplace may need more frequent cleaning due to excessive lint from carpeting, bedding material, pet hair, etc.

GLASS DOOR

WARNING: Handle glass door panel with care. Do not strike, slam, or otherwise abuse glass. Do not operate fireplace with the glass door removed, cracked, or broken.

WARNING: Do not use abra- sivecleanersasthismaydamage glass. Use a nonabrasive house- hold glass cleaner to clean glass. Do not clean glass when hot.

Glass must be cleaned periodically. During start- up it is normal for condensation to form on the inside of the glass causing lint, dust, and other airborne particles to cling to the glass surface. During initial start-up a slight film may form on the glass due to paint curing. The glass should be cleaned several times with a non-ammonia, non- abrasive household cleaner and warm water after the first two weeks of operation. Thereafter, clean the glass two or three times during each heating season, depending on the usage and circumstances present. Refer to Removing/Replacing Glass Door on page 24 of this manual when removing glass door for cleaning.

30

www.desatech.com

111250-01E

Image 30
Contents What to do if YOU Smell GAS Table of Contents Safety InformationSafety Information Product Identification Product FeaturesLocal Codes High traffic areasThis fireplace does not require electricity to operate Pre-Installation PreparationLocation and space requirements Proper clearances must be maintainedFront Top of Standoffs Vent See venting ClearancesFraming and finishing Venting clearancesLocation of Termination Cap Balcony with Perpendicular Side WallVenting Installation Instructions Installation PrecautionsInstallation Planning Installing Horizontal Vent Cap Noncombustible Exterior Ground Floor Installation 32 minSnorkel Termination Installation Recommended Applications Corner ground floor installationHorizontal System Installation Using TWO 90 Elbows Installation for vertical termination Flat Ceiling InstallationConnect a section of pipe and extend up through the hole Twist-lock the vent cap onto the last section of vent pipe High Altitude Installation Vertical VentingDesa Terminations Desa Venting AccessoriesDesa Elbows Number DescriptionModel BK Installation Fireplace InstallationInstalling optional blower accessories Check GAS TypeModel BKT Installation Plug in blower power cord to duplex outletInstalling Gas Piping to Fireplace Location Blower Wiring DiagramInstallation Items Needed Connecting Fireplace to GAS Supply Checking GAS ConnectionsPressure Testing Fireplace Gas Connections Test Pressures Equal To or Less Than Psig 3.5 kPaInstalling optional wall mount switch GWMS2 Installing Remote ReceiverOpen bottom louver and locate the switch Removing Louver Panels Cleaning Glass DoorRemoving/Replacing Glass Door Removing Glass DoorInstalling logs, lava rock and glowing embers Close top and bottom louversInstalling Log No Lighting Instructions For your safety Read before lightingOperating Fireplace To Turn OFF GAS To ApplianceOn/Off Series Models HRC100 and HRC101 Manual Lighting ProcedureOptional Hand-Held Remote OperationAuto Shutoff Feature Operating optional blower accessorySafety Features Operating optional GWMT1 Wall Mounted ThermostatInspecting Burners Cleaning MaintenancePilot Assembly Burner Flame PatternPilot and burners LogsVenting system Troubleshooting Observed Problem Possible Cause RemedyBurner orifice clogged Clean burner see Cleaning Is lit Mocouple to cool, causingProblem could be caused by Replace pilot assembly After pilot lights, keep gasOr shut off Service person Remote does not function When burner is litDirty or partially clogged 3. Clean burner see Cleaning Tery power is lowGas leak. See Warning Statement aboveTechnical Service Replacement PartsService Hints SpecificationsRolled Louver Trim kit Wall mounted on/off switch gwms2 Not ShownFace/Louver Panel kit Deflection hoodIllustrated Parts Breakdown Rear Refractory Brick Panel Left Refractory Brick PanelIllustrated Parts Breakdown 11102 111250-01E 111250-01E Warranty Information Keep this WarrantyLimited Warranty DIRECT-VENT Fireplace

(V)T36NA specifications

Desa (V)T36NA is an advanced piece of machinery designed primarily for heavy-duty applications in various industrial sectors. Known for its reliability and efficiency, this model has gained popularity among operators seeking high performance without compromising on durability.

One of the standout features of the Desa (V)T36NA is its powerful engine. It is equipped with a state-of-the-art internal combustion engine that provides robust torque and horsepower, enabling it to tackle demanding tasks with ease. This power is complemented by a highly efficient fuel system that minimizes consumption, making it both cost-effective and environmentally friendly.

The Desa (V)T36NA incorporates cutting-edge technologies that enhance its operational capabilities. Its intelligent control system allows for seamless adjustments to power settings based on task requirements. This feature not only improves performance but also extends the lifespan of the machinery by preventing overexertion. Additionally, the unit is integrated with advanced diagnostic tools that monitor performance metrics, enabling operators to identify issues before they escalate.

Another notable characteristic of the Desa (V)T36NA is its robust construction. Built from high-grade materials, this machinery is designed to withstand the rigors of tough industrial environments. The frame is reinforced to handle heavy loads and resist wear and tear, which significantly reduces maintenance costs over time.

In terms of ergonomics, the machinery is designed with user comfort in mind. The operator's cabin is spacious, providing ample room and visibility for enhanced maneuverability. The controls are intuitively laid out, ensuring that operators can make adjustments quickly and efficiently.

The Desa (V)T36NA also emphasizes safety, featuring advanced safety mechanisms such as automatic braking systems and secure cabin enclosures. These features protect both the operator and the surrounding personnel, making it a reliable choice for any workspace.

Overall, the Desa (V)T36NA represents a significant advancement in heavy machinery, combining power, efficiency, and safety in one robust package. Its innovative technologies and solid construction make it an excellent investment for industries seeking to enhance productivity while ensuring operator comfort and safety. Whether in construction, manufacturing, or other heavy-duty applications, the Desa (V)T36NA stands out as a trustworthy ally in achieving operational goals.