Note: Install restrictor into inner collar of fireplace as shown.

Vertical Venting

V = 40' max.

Note: Install restrictor into inner collar of fireplace as shown.

45° Elbow

45° Elbow

Venting with Two 90° Elbows

Vertical (V1)

Horizontal (H)

5' min.

6' max.

6' min.

12' max.

7' min.

18' max.

8' min.

20' max.

Note: Vertical (V1) + Vertical (V2) = 40' max.

Figure 23 - Vertical Venting

Configuration Using Two 90° Elbows

(Vertical Round High Wind Termination

Shown)

Figure 24 - Vertical Venting

Configuration With No Horizontal Run

(Vertical Round High Wind Termination

Shown)

High Altitude Installation

Your DESAdirect-vent fireplace has been tested and approved for elevations from 0-2,000 feet (USA) and elevations from 0-4,500 feet (Canada).

When installing this fireplace at an elevation above 2,000 feet (in the USA), you may need to decrease the input rating by changing the existing burner orifice to a smaller size. Reduce input 4% for each 1,000 feet above sea level. Check with your local gas company for proper orifice size identification.

When installing this fireplace at an elevation above 4,500 feet (in Canada), check with local authorities.

Consult your local gas company to help determine the proper orifice for your location.

For assistance with any high altitude installation, contact DESA’s Customer Service Department at 1-866-672-6040.

16

www.desatech.com

111250-01E

Image 16
Contents What to do if YOU Smell GAS Table of Contents Safety InformationSafety Information Product Features Local CodesProduct Identification High traffic areasPre-Installation Preparation Location and space requirementsThis fireplace does not require electricity to operate Proper clearances must be maintainedClearances Framing and finishingFront Top of Standoffs Vent See venting Venting clearancesLocation of Termination Cap Balcony with Perpendicular Side WallVenting Installation Instructions Installation PrecautionsInstallation Planning Installing Horizontal Vent Cap Noncombustible Exterior Ground Floor Installation 32 minSnorkel Termination Installation Recommended Applications Corner ground floor installation Horizontal System Installation Using TWO 90 Elbows Flat Ceiling Installation Installation for vertical terminationConnect a section of pipe and extend up through the hole Twist-lock the vent cap onto the last section of vent pipe High Altitude Installation Vertical VentingDesa Venting Accessories Desa ElbowsDesa Terminations Number DescriptionFireplace Installation Installing optional blower accessoriesModel BK Installation Check GAS TypeModel BKT Installation Plug in blower power cord to duplex outletBlower Wiring Diagram Installing Gas Piping to Fireplace LocationInstallation Items Needed Connecting Fireplace to GAS Supply Checking GAS ConnectionsPressure Testing Fireplace Gas Connections Test Pressures Equal To or Less Than Psig 3.5 kPaInstalling Remote Receiver Installing optional wall mount switch GWMS2Open bottom louver and locate the switch Cleaning Glass Door Removing/Replacing Glass DoorRemoving Louver Panels Removing Glass DoorInstalling logs, lava rock and glowing embers Close top and bottom louversInstalling Log No For your safety Read before lighting Operating FireplaceLighting Instructions To Turn OFF GAS To ApplianceManual Lighting Procedure Optional Hand-HeldOn/Off Series Models HRC100 and HRC101 Remote OperationOperating optional blower accessory Safety FeaturesAuto Shutoff Feature Operating optional GWMT1 Wall Mounted ThermostatCleaning Maintenance Pilot AssemblyInspecting Burners Burner Flame PatternLogs Pilot and burnersVenting system Troubleshooting Observed Problem Possible Cause RemedyMocouple to cool, causing Problem could be caused by Replace pilot assemblyBurner orifice clogged Clean burner see Cleaning Is lit After pilot lights, keep gasWhen burner is lit Dirty or partially clogged 3. Clean burner see CleaningOr shut off Service person Remote does not function Tery power is lowGas leak. See Warning Statement aboveReplacement Parts Service HintsTechnical Service SpecificationsWall mounted on/off switch gwms2 Not Shown Face/Louver Panel kitRolled Louver Trim kit Deflection hoodIllustrated Parts Breakdown Rear Refractory Brick Panel Left Refractory Brick PanelIllustrated Parts Breakdown 11102 111250-01E 111250-01E Keep this Warranty Warranty InformationLimited Warranty DIRECT-VENT Fireplace