Desa (V)T36NA Operating optional GWMT1 Wall Mounted Thermostat, Safety Features

Page 29

OPERATIng fireplace

Continued

4.Press the POWER and LOCK buttons together to turn off the fireplace

Note: Do not leave the hand-held remote in the AUTO mode close to the fireplace. The radiant heat from the fireplace will turn off the fireplace. Ideally, place the hand-held remote in the center of the room facing towards the fireplace.

Note: Do not hold the hand-held remote for a long time. Body temperature will affect its operation in the AUTO mode.

Safety Features

When away from home for an extended period of time or as a child safety feature to prevent accidental ignition of the fireplace, the receiver ON/OFF/REMOTE switch should be in the OFF position.

Auto Shutoff Feature

1. If the average room temperature exceeds 82° F (28° C), the hand-held remote control will perform a safety override and shut the fireplace off. This feature is not available in the MANU mode.

2. The receiver continuously receives signals from the hand-held remote to control the room temperature. If the hand-held remote is misplaced, obstructed or for any reason cannot transmit to the receiver, the receiver will shut off the fireplace after 8 minutes.

Digital Display Shows

Temperature and Settings

Locks

 

 

 

Turns

System to

 

 

 

 

 

 

Hand-Held

Prevent

 

AUTO

TEMP

Remote On

Accidental

 

TEMP

 

ROOM

 

SET

 

Ignition

 

 

 

or Off and

 

 

 

Allows You

Turns

LOCK

TEMP

POWER

Burners

 

 

 

to Choose

 

 

 

the Manual

On or

 

 

 

MANU

ºC/ºF AUTO

Setting

Off

 

 

 

Selects

 

 

 

 

Increases or

 

 

 

AUTO

Decreases

 

 

 

Mode

Room

 

 

 

 

Temperature

 

 

 

°C/°F Mode

in AUTO

 

 

 

 

 

 

Button

Mode

 

 

 

 

 

 

 

Figure 53 - Thermostat Hand-Held

Remote Control Unit HRC200

Operating optional

GWMT1 Wall Mounted

Thermostat

WARNING: Do not con- nect the thermostat to a power source. Electrical shock and/or a fire hazard will occur.

Light the fireplace as instructed in Lighting Instructions on page 27. Set wall thermostat to desired temperature.

This thermostat has been electronically cali- brated at the factory and requires no adjust- ment or leveling.

Upon installation, the thermostat must be al- lowed to stabilize at room temperature for a minimum of 30 minutes for proper operation. To turn the fireplace off, adjust thermostat to the lowest setting and turn the gas control knob back to PILOT. The pilot will remain lit.

IMPORTANT: To turn the pilot off, turn the gas control knob on the heater to the OFF position.

operating optional blower accessory

Locate the blower controls by opening the lower louver panel on the fireplace. Blower controls are located on the left side of the switch bracket to the left just inside the louver panel.

The BK manual blower and the BKT thermo- statically-controlled blower have an ON setting and an OFF setting. The blower will only run when the switch is in the ON position. In the OFF position, the blower will not operate.

Note for BKT Only: If you are using BKT blower with optional thermostat (wall mounted or remote control) for the fireplace, your fire- place and blower will not turn on and off at the same time. The fireplace may run for several minutes before the blower turns on. After the heater modulates to the pilot position, the blow- er will continue to run. The blower will shut off after the firebox temperature decreases.

The blower helps distribute heated air from the fireplace. Periodically check the louvers of the firebox and remove any dust, dirt, or other obstructions that will hinder the flow of air.

111250-01E

www.desatech.com

29

Image 29
Contents What to do if YOU Smell GAS Safety Information Table of ContentsSafety Information Local Codes Product FeaturesProduct Identification High traffic areasLocation and space requirements Pre-Installation PreparationThis fireplace does not require electricity to operate Proper clearances must be maintainedFraming and finishing ClearancesFront Top of Standoffs Vent See venting Venting clearancesBalcony with Perpendicular Side Wall Location of Termination CapInstallation Precautions Venting Installation InstructionsInstallation Planning Installing Horizontal Vent Cap Noncombustible Exterior 32 min Ground Floor InstallationRecommended Applications Corner ground floor installation Snorkel Termination InstallationHorizontal System Installation Using TWO 90 Elbows Connect a section of pipe and extend up through the hole Installation for vertical terminationFlat Ceiling Installation Twist-lock the vent cap onto the last section of vent pipe Vertical Venting High Altitude InstallationDesa Elbows Desa Venting AccessoriesDesa Terminations Number DescriptionInstalling optional blower accessories Fireplace InstallationModel BK Installation Check GAS TypePlug in blower power cord to duplex outlet Model BKT InstallationInstallation Items Needed Installing Gas Piping to Fireplace LocationBlower Wiring Diagram Checking GAS Connections Connecting Fireplace to GAS SupplyTest Pressures Equal To or Less Than Psig 3.5 kPa Pressure Testing Fireplace Gas ConnectionsOpen bottom louver and locate the switch Installing optional wall mount switch GWMS2Installing Remote Receiver Removing/Replacing Glass Door Cleaning Glass DoorRemoving Louver Panels Removing Glass DoorClose top and bottom louvers Installing logs, lava rock and glowing embersInstalling Log No Operating Fireplace For your safety Read before lightingLighting Instructions To Turn OFF GAS To ApplianceOptional Hand-Held Manual Lighting ProcedureOn/Off Series Models HRC100 and HRC101 Remote OperationSafety Features Operating optional blower accessoryAuto Shutoff Feature Operating optional GWMT1 Wall Mounted ThermostatPilot Assembly Cleaning MaintenanceInspecting Burners Burner Flame PatternVenting system Pilot and burnersLogs Observed Problem Possible Cause Remedy TroubleshootingProblem could be caused by Replace pilot assembly Mocouple to cool, causingBurner orifice clogged Clean burner see Cleaning Is lit After pilot lights, keep gasDirty or partially clogged 3. Clean burner see Cleaning When burner is litOr shut off Service person Remote does not function Tery power is lowStatement above Gas leak. See WarningService Hints Replacement PartsTechnical Service SpecificationsFace/Louver Panel kit Wall mounted on/off switch gwms2 Not ShownRolled Louver Trim kit Deflection hoodIllustrated Parts Breakdown Left Refractory Brick Panel Rear Refractory Brick PanelIllustrated Parts Breakdown 11102 111250-01E 111250-01E Limited Warranty DIRECT-VENT Fireplace Warranty InformationKeep this Warranty

(V)T36NA specifications

Desa (V)T36NA is an advanced piece of machinery designed primarily for heavy-duty applications in various industrial sectors. Known for its reliability and efficiency, this model has gained popularity among operators seeking high performance without compromising on durability.

One of the standout features of the Desa (V)T36NA is its powerful engine. It is equipped with a state-of-the-art internal combustion engine that provides robust torque and horsepower, enabling it to tackle demanding tasks with ease. This power is complemented by a highly efficient fuel system that minimizes consumption, making it both cost-effective and environmentally friendly.

The Desa (V)T36NA incorporates cutting-edge technologies that enhance its operational capabilities. Its intelligent control system allows for seamless adjustments to power settings based on task requirements. This feature not only improves performance but also extends the lifespan of the machinery by preventing overexertion. Additionally, the unit is integrated with advanced diagnostic tools that monitor performance metrics, enabling operators to identify issues before they escalate.

Another notable characteristic of the Desa (V)T36NA is its robust construction. Built from high-grade materials, this machinery is designed to withstand the rigors of tough industrial environments. The frame is reinforced to handle heavy loads and resist wear and tear, which significantly reduces maintenance costs over time.

In terms of ergonomics, the machinery is designed with user comfort in mind. The operator's cabin is spacious, providing ample room and visibility for enhanced maneuverability. The controls are intuitively laid out, ensuring that operators can make adjustments quickly and efficiently.

The Desa (V)T36NA also emphasizes safety, featuring advanced safety mechanisms such as automatic braking systems and secure cabin enclosures. These features protect both the operator and the surrounding personnel, making it a reliable choice for any workspace.

Overall, the Desa (V)T36NA represents a significant advancement in heavy machinery, combining power, efficiency, and safety in one robust package. Its innovative technologies and solid construction make it an excellent investment for industries seeking to enhance productivity while ensuring operator comfort and safety. Whether in construction, manufacturing, or other heavy-duty applications, the Desa (V)T36NA stands out as a trustworthy ally in achieving operational goals.