Desa (V)T36NA installation manual Pre-Installation Preparation, Location and space requirements

Page 5

Product Features

Continued

This fireplace requires a wall switch, hand-held remote or wall thermostat (millivolt) for opera- tion (see Accessories, page 36).

This fireplace does not require electricity to operate.

Only the blower requires electricity if installed and if you plan to install the blower at a later date, do not forget to wire the outlet at the bot- tom of the fireplace when framing.

A piezo ignitor and ceramic electrode create spark to ignite the pilot light. It does not require any matches, batteries or any other sources of ignition to light the pilot.

Each time you turn on your fireplace, you may notice some amount of condensation on the in- side of the fireplace glass. This is normal and will disappear after 10-20 minutes of operation.

Your direct-vent gas fireplace system (fireplace and venting) is a balanced and sealed gas op- erating unit. It requires approximately 10-20 minutes of operating time before the flame pattern stabilizes.

Pre-Installation

Preparation

Location and space requirements

Determine the safest and most efficient location for your DESA direct-vent fireplace. Make sure that rafters and wall studs are not in the way of the venting system. Choose a location where the heat output is not affected by drafts, air conditioning ducts, windows or doors. Figure 2 shows some common locations. Be aware of all restrictions and precautions before deciding the exact location for your fireplace and termination cap.

When deciding the location of your fireplace, follow these rules:

Do not connect this fireplace venting to a chim- ney flue serving a separate solid-fuel burning fireplace or appliance.

Due to high temperatures, do not locate this fireplace in high traffic areas, windy or drafty areas or near furniture or draperies.

Proper clearances must be maintained.

If your fireplace is to be installed directly on carpeting, vinyl tile or any combustible mate- rial other than wood, it must be installed on a metal or wood panel extending the full width and depth of the fireplace. See Figure 3.

Your fireplace is designed to be used in zero clear- ance installations. Wall or framing material can be placed directly against any exterior surface on the back, sides or top of your fireplace, except where standoff spacers are integrally attached. If standoff spacers are attached to your fireplace, these spac- ers can be placed directly against wall or framing material. See framing details on page 6.

If you plan on installing a television or enter- tainment center recessed above your fireplace, it is recommended that you maintain a minimum 18" above top of louver opening.

When locating termination cap, it is important to observe the minimum clearances shown in Figure 7, page 7.

If recessing into a wall, you can avoid extra framing by positioning your fireplace against an already existing framing member.

Do not recess termination cap into a wall or siding.

You may paint the termination cap with 450º F (232º C) heat-resistant paint to coordinate with the exterior finish.

There must not be any obstruction such as bushes, garden sheds, fences, decks or utility buildings within 24" from the front of the termination cap.

Do not locate termination cap where excessive snow or ice build up may occur. Be sure to clear vent termination area after snow falls to prevent accidental blockage of venting system. When using snow blowers, do not direct snow towards vent termination area.

Flush with a wall

Through exterior wall enclosed in a chase

Corner installation

Figure 2 - Common Fireplace Locations

29"

21 1/8"

41"

Figure 3 - Fireplace Bottom Dimensions

111250-01Ewww.desatech.com

Image 5
Contents What to do if YOU Smell GAS Safety Information Table of ContentsSafety Information Local Codes Product FeaturesProduct Identification High traffic areasLocation and space requirements Pre-Installation PreparationThis fireplace does not require electricity to operate Proper clearances must be maintainedFraming and finishing ClearancesFront Top of Standoffs Vent See venting Venting clearancesBalcony with Perpendicular Side Wall Location of Termination CapInstallation Precautions Venting Installation InstructionsInstallation Planning Installing Horizontal Vent Cap Noncombustible Exterior 32 min Ground Floor InstallationRecommended Applications Corner ground floor installation Snorkel Termination InstallationHorizontal System Installation Using TWO 90 Elbows Connect a section of pipe and extend up through the hole Installation for vertical terminationFlat Ceiling Installation Twist-lock the vent cap onto the last section of vent pipe Vertical Venting High Altitude InstallationDesa Elbows Desa Venting AccessoriesDesa Terminations Number DescriptionInstalling optional blower accessories Fireplace InstallationModel BK Installation Check GAS TypePlug in blower power cord to duplex outlet Model BKT InstallationInstallation Items Needed Installing Gas Piping to Fireplace LocationBlower Wiring Diagram Checking GAS Connections Connecting Fireplace to GAS SupplyTest Pressures Equal To or Less Than Psig 3.5 kPa Pressure Testing Fireplace Gas ConnectionsOpen bottom louver and locate the switch Installing optional wall mount switch GWMS2Installing Remote Receiver Removing/Replacing Glass Door Cleaning Glass DoorRemoving Louver Panels Removing Glass DoorClose top and bottom louvers Installing logs, lava rock and glowing embersInstalling Log No Operating Fireplace For your safety Read before lightingLighting Instructions To Turn OFF GAS To ApplianceOptional Hand-Held Manual Lighting ProcedureOn/Off Series Models HRC100 and HRC101 Remote OperationSafety Features Operating optional blower accessoryAuto Shutoff Feature Operating optional GWMT1 Wall Mounted ThermostatPilot Assembly Cleaning MaintenanceInspecting Burners Burner Flame PatternVenting system Pilot and burnersLogs Observed Problem Possible Cause Remedy TroubleshootingProblem could be caused by Replace pilot assembly Mocouple to cool, causingBurner orifice clogged Clean burner see Cleaning Is lit After pilot lights, keep gasDirty or partially clogged 3. Clean burner see Cleaning When burner is litOr shut off Service person Remote does not function Tery power is lowStatement above Gas leak. See WarningService Hints Replacement PartsTechnical Service SpecificationsFace/Louver Panel kit Wall mounted on/off switch gwms2 Not ShownRolled Louver Trim kit Deflection hoodIllustrated Parts Breakdown Left Refractory Brick Panel Rear Refractory Brick PanelIllustrated Parts Breakdown 11102 111250-01E 111250-01E Limited Warranty DIRECT-VENT Fireplace Warranty InformationKeep this Warranty

(V)T36NA specifications

Desa (V)T36NA is an advanced piece of machinery designed primarily for heavy-duty applications in various industrial sectors. Known for its reliability and efficiency, this model has gained popularity among operators seeking high performance without compromising on durability.

One of the standout features of the Desa (V)T36NA is its powerful engine. It is equipped with a state-of-the-art internal combustion engine that provides robust torque and horsepower, enabling it to tackle demanding tasks with ease. This power is complemented by a highly efficient fuel system that minimizes consumption, making it both cost-effective and environmentally friendly.

The Desa (V)T36NA incorporates cutting-edge technologies that enhance its operational capabilities. Its intelligent control system allows for seamless adjustments to power settings based on task requirements. This feature not only improves performance but also extends the lifespan of the machinery by preventing overexertion. Additionally, the unit is integrated with advanced diagnostic tools that monitor performance metrics, enabling operators to identify issues before they escalate.

Another notable characteristic of the Desa (V)T36NA is its robust construction. Built from high-grade materials, this machinery is designed to withstand the rigors of tough industrial environments. The frame is reinforced to handle heavy loads and resist wear and tear, which significantly reduces maintenance costs over time.

In terms of ergonomics, the machinery is designed with user comfort in mind. The operator's cabin is spacious, providing ample room and visibility for enhanced maneuverability. The controls are intuitively laid out, ensuring that operators can make adjustments quickly and efficiently.

The Desa (V)T36NA also emphasizes safety, featuring advanced safety mechanisms such as automatic braking systems and secure cabin enclosures. These features protect both the operator and the surrounding personnel, making it a reliable choice for any workspace.

Overall, the Desa (V)T36NA represents a significant advancement in heavy machinery, combining power, efficiency, and safety in one robust package. Its innovative technologies and solid construction make it an excellent investment for industries seeking to enhance productivity while ensuring operator comfort and safety. Whether in construction, manufacturing, or other heavy-duty applications, the Desa (V)T36NA stands out as a trustworthy ally in achieving operational goals.