Desa (V)T36NA Local Codes, Product Identification, Product Features, High traffic areas

Page 4

Safety information

Continued

2.If you smell gas

shut off gas supply

do not try to light any appliance

do not touch any electrical switch; do not use any phone in your building

immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier's instructions

if you cannot reach you gas supplier, call the fire department.

3.Never install the fireplace

in a recreational vehicle

in windy or drafty areas where curtains or other combustible (flammable) objects can make contact with the fireplace front

in high traffic areas

4.Turn appliance off and let cool before servic- ing, installing or repairing. Only a qualified service person should install, service or repair this fireplace. Have fireplace inspected annu- ally by a qualified service person.

5.You must keep control compartments, burn- ers and circulating air passages clean. More frequent cleaning may be needed due to ex- cessive lint and dust from carpeting, bedding material, etc. Turn off the gas valve and pilot light before cleaning fireplace.

6.Have venting system inspected annually by a qualified service person. If needed, have venting system cleaned or repaired.

7.Do not use any solid fuels (wood, coal, paper, cardboard, etc.) in this fireplace.

8.This appliance, when installed, must be electri- cally grounded in accordance with local codes or, in the absence of local codes, with the

National Electrical Code, ANSI/NFPA 70 or the Canadian Electrical Code, CSA C22.1.

9.Do not use fireplace if any part has been ex- posed to or under water. Immediately call a qualified service person to arrange for replace- ment of the unit.

10.Do not operate fireplace if any log is broken.

11.Do not operate fireplace with glass door removed, cracked or broken.

12.Provide adequate clearances around air openings.

Local Codes

Install and use fireplace with care. Follow all local codes. In the absence to local codes, use the cur- rent National Fuel Gas Code ANSI Z223.1/NFPA 54* (USA) or the current CSA-B149.1 Installation Code (Canada).

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

Product

Identification

Upper Louver

Flue Collar

Panel

 

 

 

 

Nailing

 

 

Log Set

 

 

 

Flange

 

 

 

Glass Door

 

 

Assembly

 

 

 

Glowing

 

 

 

Embers

 

 

 

Lower

 

 

 

Louver

 

 

 

Panel

 

 

 

Piezo

 

 

 

Ignitor

 

 

 

Control

Grate

 

 

Valve

Assembly

 

 

 

ON/OFF/

 

Lava Rock

 

REMOTE

 

 

 

 

 

Switch (Optional

Blower Switch

 

Installation)

 

(Optional

Installation)

Figure 1 - Tudor Direct-Vent Fireplace

with Millivolt Ignition

Product Features

These are a few facts that can help you understand and enjoy your direct-vent fireplace:

The venting system may be routed to the outside of your home in several ways. It may vent through the roof (vertical) or it may vent to an outside/exte- rior wall (horizontal). The vent pipe installation is very important to allow for proper operation. You must follow the venting instructions very carefully for either vertical or horizontal applications.

This fireplace may be installed in any room of your house provided all local codes and these installation instructions are followed.

www.desatech.com111250-01E

Image 4
Contents What to do if YOU Smell GAS Table of Contents Safety InformationSafety Information Product Features Local CodesProduct Identification High traffic areasPre-Installation Preparation Location and space requirementsThis fireplace does not require electricity to operate Proper clearances must be maintainedClearances Framing and finishingFront Top of Standoffs Vent See venting Venting clearancesLocation of Termination Cap Balcony with Perpendicular Side WallVenting Installation Instructions Installation PrecautionsInstallation Planning Installing Horizontal Vent Cap Noncombustible Exterior Ground Floor Installation 32 minSnorkel Termination Installation Recommended Applications Corner ground floor installationHorizontal System Installation Using TWO 90 Elbows Flat Ceiling Installation Installation for vertical terminationConnect a section of pipe and extend up through the hole Twist-lock the vent cap onto the last section of vent pipe High Altitude Installation Vertical VentingDesa Venting Accessories Desa ElbowsDesa Terminations Number DescriptionFireplace Installation Installing optional blower accessoriesModel BK Installation Check GAS TypeModel BKT Installation Plug in blower power cord to duplex outletBlower Wiring Diagram Installing Gas Piping to Fireplace LocationInstallation Items Needed Connecting Fireplace to GAS Supply Checking GAS ConnectionsPressure Testing Fireplace Gas Connections Test Pressures Equal To or Less Than Psig 3.5 kPaInstalling Remote Receiver Installing optional wall mount switch GWMS2Open bottom louver and locate the switch Cleaning Glass Door Removing/Replacing Glass DoorRemoving Louver Panels Removing Glass DoorInstalling logs, lava rock and glowing embers Close top and bottom louversInstalling Log No For your safety Read before lighting Operating FireplaceLighting Instructions To Turn OFF GAS To ApplianceManual Lighting Procedure Optional Hand-HeldOn/Off Series Models HRC100 and HRC101 Remote OperationOperating optional blower accessory Safety FeaturesAuto Shutoff Feature Operating optional GWMT1 Wall Mounted ThermostatCleaning Maintenance Pilot AssemblyInspecting Burners Burner Flame PatternLogs Pilot and burnersVenting system Troubleshooting Observed Problem Possible Cause RemedyMocouple to cool, causing Problem could be caused by Replace pilot assemblyBurner orifice clogged Clean burner see Cleaning Is lit After pilot lights, keep gasWhen burner is lit Dirty or partially clogged 3. Clean burner see CleaningOr shut off Service person Remote does not function Tery power is lowGas leak. See Warning Statement aboveReplacement Parts Service HintsTechnical Service SpecificationsWall mounted on/off switch gwms2 Not Shown Face/Louver Panel kitRolled Louver Trim kit Deflection hoodIllustrated Parts Breakdown Rear Refractory Brick Panel Left Refractory Brick PanelIllustrated Parts Breakdown 11102 111250-01E 111250-01E Keep this Warranty Warranty InformationLimited Warranty DIRECT-VENT Fireplace

(V)T36NA specifications

Desa (V)T36NA is an advanced piece of machinery designed primarily for heavy-duty applications in various industrial sectors. Known for its reliability and efficiency, this model has gained popularity among operators seeking high performance without compromising on durability.

One of the standout features of the Desa (V)T36NA is its powerful engine. It is equipped with a state-of-the-art internal combustion engine that provides robust torque and horsepower, enabling it to tackle demanding tasks with ease. This power is complemented by a highly efficient fuel system that minimizes consumption, making it both cost-effective and environmentally friendly.

The Desa (V)T36NA incorporates cutting-edge technologies that enhance its operational capabilities. Its intelligent control system allows for seamless adjustments to power settings based on task requirements. This feature not only improves performance but also extends the lifespan of the machinery by preventing overexertion. Additionally, the unit is integrated with advanced diagnostic tools that monitor performance metrics, enabling operators to identify issues before they escalate.

Another notable characteristic of the Desa (V)T36NA is its robust construction. Built from high-grade materials, this machinery is designed to withstand the rigors of tough industrial environments. The frame is reinforced to handle heavy loads and resist wear and tear, which significantly reduces maintenance costs over time.

In terms of ergonomics, the machinery is designed with user comfort in mind. The operator's cabin is spacious, providing ample room and visibility for enhanced maneuverability. The controls are intuitively laid out, ensuring that operators can make adjustments quickly and efficiently.

The Desa (V)T36NA also emphasizes safety, featuring advanced safety mechanisms such as automatic braking systems and secure cabin enclosures. These features protect both the operator and the surrounding personnel, making it a reliable choice for any workspace.

Overall, the Desa (V)T36NA represents a significant advancement in heavy machinery, combining power, efficiency, and safety in one robust package. Its innovative technologies and solid construction make it an excellent investment for industries seeking to enhance productivity while ensuring operator comfort and safety. Whether in construction, manufacturing, or other heavy-duty applications, the Desa (V)T36NA stands out as a trustworthy ally in achieving operational goals.