Desa VDCFTNA Installing Optional Blower Accessory GA3450TA, Removing Upper Louver

Page 13

INSTALLATION

Continued

5.Center cabinet mantel on hearth base (see Figure 12). Make sure mantel is flush against wall and centered left to right on base.

6.Use screws provided with mantel accessory to attach mantel assembly to base (see mantel instruction sheet).

7.Attach flexible gas line to fireplace gas regula- tor. See Connecting to Gas Supply, page 16.

8.Route electrical cord(s) through access holes in either side of fireplace with bushing. Plug electrical cord(s) into electrical outlet.

9.Check all gas connections for leaks. See

Checking Gas Connections, page 17.

10.Carefully insert fireplace into cabinet mantel (see Figure 13). Be careful not to scratch or damage hearth base or cabinet mantel.

11.Place metal trim on shoulder screws located on the side and top of the fireplace (see Assem- bling Perimeter Trim). Firmly snap trim over shoulder screws. Align fireplace in mantel assembly so the trim overlaps mantel evenly on all three sides.

12.Lower bottom louver door. Use 3" wood screws provided with mantel accessory to at- tach fireplace to base (see mantel instruction sheet).

Cabinet

Mantel

Hearth

Base

Cabinet

Mantel

Assembled

Trim

Hearth Base

Figure 13 - Installing Fireplace into

Mantel Assembly

Assembling Perimeter Trim (Perimeter

trim shipped with mantel)

1. Remove packaging from three remaining pieces of trim.

2. Locate two adjusting plates with set screws and two shims in the hardware packet.

3. Align shim under adjusting plate as shown in Figure 14.

4. Slide one end of adjusting plate/shim in slot on mitered edge of top trim (see Figure 14).

5. Slide other end of adjusting plate/shim in slot on mitered edge of side perimeter trim (see Figure 14).

6. While firmly holding edges of perimeter trim together, tighten both set screws on the adjust- ing plate with slotted screwdriver.

7. Repeat steps 1 through 6 for other corner.

8. Set perimeter trim assembly aside for later installation.

Adjusting Plate

Set Screws

Figure 12 - Installing Cabinet Mantel onto

Hearth Base

Slot

Top Trim

Shim

Mitered Edge

 

Side Trim

Figure 14 - Assembling Perimeter Trim

Installing Optional Blower Accessory GA3450TA

Removing Upper Louver

To install the blower accessory, you must first remove the upper louver.

1.Lift screen off fireplace and remove log set if installed.

113133-01C

www.desatech.com

13

Image 13
Contents Thermostat Models Vdcftna and Vdcftpa Remote-Ready Models Shown with Optional Cabinet Mantel/Hearth Base AccessoryVdcfrpa and Vdcfrna Table of Contents Safety Information Safety Information Product Features Optional Remote Control AccessoriesProduct Identification Local CodesAir for Combustion Ventilation Hood AssemblyTools Required Phillips screwdriver Providing Adequate Ventilation AIR for Combustion VentilationDetermining FRESH-AIR Flow for Fireplace Location Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Check GAS Type InstallationInstallation Items InstallationFireplace Clearances Fireplace pilot and burner must be at least 18 above floorIf you have not installed hood, follow instruc- tions on Built-In Fireplace InstallationRoute flexible gas line through access hole in hearth base Optional Mantel InstallationCheck all gas connections for leaks. See Installing Optional Blower Accessory GA3450TARemoving Upper Louver Remove 4 screws from upper louver see . Save these screws Installing Blower AccessoryOpen lower louver door by swinging door down see Figure Extension Cord For Built-In InstallationExternal Regulator With Vent Pointing Down Connecting to GAS SupplyInstallation Items Needed Connecting equipment shutoff valve to heater controlChecking GAS Connections Equipment Shutoff Valve Pressure Testing Fireplace Gas ConnectionsInstalling 9-Volt Battery in Hand-Held Remote Control Unit Installing ReceiverRemove battery cover on back of remote control unit Replace battery cover onto remote control unitRemove jumper wire from control valve see , Optional Wall Switch GWMS2 Remote-Ready Models OnlyFor Your Safety Read Before Lighting Installing LOG SET and ScreenOperating Fireplace Lighting InstructionsOperating Fireplace Manual Lighting ProcedureTo Turn OFF GAS To Appliance Thermostat Control OperationOperating Blower AUTO/OFF/ON Blower SwitchDepress control knob and light pilot with match Remote Operation Optional Hand-HeldOn/Off Series Model HRC100 Thermostat Series Model HRC200Safety Features Optional GWMS2 Wall Mounted SwitchAuto Shutoff Feature Key Pad Lock FeatureInspecting Burners Cleaning MaintenancePilot Flame Pattern Burner Flame PatternWiring Diagram Cleaning MaintenanceLOG Set CabinetObserved Problem Possible Cause Remedy TroubleshootingTroubleshooting Mote-Ready Models Only Power is low When heated, vapors fromSlight smoke or odor during Initial operation Processes and log curingGas leak. See Warning VDCFTPA, Vdcfrpa SpecificationsFirebox Models VDC Illustrated Parts BreakdownParts List Thermostat Models Illustrated Parts BreakdownVdcftpa and Vdcftna Parts List Vdcfrna and Vdcfrpa REMOTE-READY ModelsKEY Equipment Shutoff Valve GA5010 AccessoriesTHERMOSTAT-CONTROLLED Blower KIT GA3450T WALL-MOUNT ON/OFF Switch AccessoriesReceiver and HAND-HELD Thermostat Remote Control KIT HRC200 Receiver and HAND-HELD Remote Control KIT HRC100Service Hints Replacement PartsTechnical Service Parts Under Warranty113133-01C Keep this Warranty Warranty InformationLimited Warranty VENT-FREE Compact Classic Hearth