Desa VDCFTNA Installing Receiver, Installing 9-Volt Battery in Hand-Held Remote Control Unit

Page 19

INSTALLATION

Continued

OPTIONAL Wireless hand-held REMOTE CONTROL ACCESSORies Remote-Ready Models Only HRC100 & HRC200 Series

Installing Receiver

1. Disconnect wires from the control valve (see Figure 28).

2. Locate the battery clip mounted on the back of the receiver (see Figure 29).

3. Slide 9-volt battery (not included) through the clip.

4. Attach the terminal wires to the battery (see Figure 29).

5. Connect wires from remote receiver to control valve as shown in Figure 30.

6. Install remote receiver unit onto remote/ blower bracket using screws provided (see Figure 30).

Figure 28 - Disconnecting Wires From

Control Valve

Receiver

9-Volt

Terminal

Battery

Wires

 

Battery Clip

Figure 29 - Attaching Battery to Receiver

White Wire to

TH Terminal on

Control Valve

Remote

Receiver

Red Wire to

TPTH Terminal on

Control Valve

Figure 30 - Installing Remote Receiver

Installing 9-Volt Battery in Hand-Held

Remote Control Unit

1. Remove battery cover on back of remote control unit.

2. Attach terminal wires to the battery (not in- cluded). Place battery into the battery housing.

3. Replace battery cover onto remote control unit.

Battery Cover

Remote Control Unit

 

Terminal

Wires

Battery

Housing

9-Volt Battery

Figure 31 - Installing Battery in Hand-

Held Remote Control Unit

optional Wall Mounted Thermostat - GWMT1 (Remote-Ready Models Only)

WARNING: Read and fol- low installation instructions. Installation should be done by a qualified installer familiar with low-voltage wiring procedures.

WARNING: Do not connect this thermostat to any electrical source! Electrical shock and/or fire hazard will occur.

1.Remove jumper wire from control valve (see Figure 28).

2.Connect one terminal of 25 ft. wire to the “TH” terminal on the control valve. Connect the other terminal to the “THTP” terminal on the control valve. See Figure 32, page 20.

3.Route the 25 ft. wire to a convenient location to mount your thermostat (no outside wall).

IMPORTANT: The wire may be shortened but must not be lengthened.

The thermostat should be mounted 54" above the floor in a location where there is good air circulation. Avoid heat sources such as lamps, direct sunlight, fireplace or heat and air conditioning ducts.

113133-01C

www.desatech.com

19

Image 19
Contents Thermostat Models Vdcftna and Vdcftpa Remote-Ready Models Shown with Optional Cabinet Mantel/Hearth Base AccessoryVdcfrpa and Vdcfrna Table of Contents Safety Information Safety Information Local Codes Optional Remote Control AccessoriesProduct Features Product IdentificationAir for Combustion Ventilation Hood AssemblyTools Required Phillips screwdriver Providing Adequate Ventilation AIR for Combustion VentilationDetermining FRESH-AIR Flow for Fireplace Location Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Check GAS Type InstallationFireplace pilot and burner must be at least 18 above floor InstallationInstallation Items Fireplace ClearancesIf you have not installed hood, follow instruc- tions on Built-In Fireplace InstallationRoute flexible gas line through access hole in hearth base Optional Mantel InstallationCheck all gas connections for leaks. See Installing Optional Blower Accessory GA3450TARemoving Upper Louver Remove 4 screws from upper louver see . Save these screws Installing Blower AccessoryOpen lower louver door by swinging door down see Figure Extension Cord For Built-In InstallationExternal Regulator With Vent Pointing Down Connecting to GAS SupplyInstallation Items Needed Connecting equipment shutoff valve to heater controlChecking GAS Connections Equipment Shutoff Valve Pressure Testing Fireplace Gas ConnectionsReplace battery cover onto remote control unit Installing ReceiverInstalling 9-Volt Battery in Hand-Held Remote Control Unit Remove battery cover on back of remote control unitRemove jumper wire from control valve see , Optional Wall Switch GWMS2 Remote-Ready Models OnlyLighting Instructions Installing LOG SET and ScreenFor Your Safety Read Before Lighting Operating FireplaceThermostat Control Operation Manual Lighting ProcedureOperating Fireplace To Turn OFF GAS To ApplianceOperating Blower AUTO/OFF/ON Blower SwitchDepress control knob and light pilot with match Thermostat Series Model HRC200 Optional Hand-HeldRemote Operation On/Off Series Model HRC100Key Pad Lock Feature Optional GWMS2 Wall Mounted SwitchSafety Features Auto Shutoff FeatureBurner Flame Pattern Cleaning MaintenanceInspecting Burners Pilot Flame PatternCabinet Cleaning MaintenanceWiring Diagram LOG SetObserved Problem Possible Cause Remedy TroubleshootingTroubleshooting Initial operation Processes and log curing When heated, vapors fromMote-Ready Models Only Power is low Slight smoke or odor duringGas leak. See Warning VDCFTPA, Vdcfrpa SpecificationsFirebox Models VDC Illustrated Parts BreakdownParts List Thermostat Models Illustrated Parts BreakdownVdcftpa and Vdcftna Parts List Vdcfrna and Vdcfrpa REMOTE-READY ModelsKEY Equipment Shutoff Valve GA5010 AccessoriesTHERMOSTAT-CONTROLLED Blower KIT GA3450T Receiver and HAND-HELD Remote Control KIT HRC100 AccessoriesWALL-MOUNT ON/OFF Switch Receiver and HAND-HELD Thermostat Remote Control KIT HRC200Parts Under Warranty Replacement PartsService Hints Technical Service113133-01C Keep this Warranty Warranty InformationLimited Warranty VENT-FREE Compact Classic Hearth