Desa VDCFTNA Product Identification, Optional Remote Control Accessories, Local Codes, Unpacking

Page 5

Product

Identification

Fireplace

Cabinet

Hood

Screen

Log

 

Ignitor Button

Control

 

 

Knob

 

Fireplace Cabinet

Hood

Logs

Ignitor

Button

Remote

 

Control

Control Knob

(Optional)

Figure 1 - Vent-Free Compact Dual Flame

Fireplace

Optional Remote

Control Accessories

(For Remote-Ready Models Only)

There are four optional remote controls that can be purchased separately for Remote-Ready Models only:

wall switch

hand-held ON/OFF remote

wall thermostat

hand-held thermostat remote See Accessories, page 40.

Local Codes

Install and use fireplace with care. Follow all local codes. In the absence of local codes, use the lat- est edition of The National Fuel Gas Code ANSI Z223.1/NFPA 54*.

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

Product Features

Safety Pilot

This fireplace has a pilot with an Oxygen Deple- tion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feature for vent-free room fireplaces. The ODS/pilot shuts off the fireplace if there is not enough fresh air.

Piezo Ignition System

This fireplace has a piezo ignitor. This system requires no matches, batteries or other sources to light fireplace.

Thermostatic Heat Control for thermostat-Controlled Models

Thermostat-Controlled models have a thermostat sensing bulb and a control valve. The thermostat will automatically modulate the heat output to maintain a consistent room temperature. This results in greater fireplace comfort. This can also result in lower gas bills.

Unpacking

1.Remove fireplace and hood from carton.

Log is wrapped and inside fireplace. Do not remove at this time.

2.Remove all protective packaging applied to fireplace for shipment.

3.Make sure your fireplace includes one hard- ware packet.

4.Check fireplace for any shipping damage. If fireplace is damaged, promptly inform dealer where you bought fireplace.

113133-01Cwww.desatech.com

Image 5
Contents Vdcfrpa and Vdcfrna Shown with Optional Cabinet Mantel/Hearth Base AccessoryThermostat Models Vdcftna and Vdcftpa Remote-Ready Models Table of Contents Safety Information Safety Information Product Features Optional Remote Control AccessoriesProduct Identification Local CodesTools Required Phillips screwdriver Hood AssemblyAir for Combustion Ventilation Determining FRESH-AIR Flow for Fireplace Location AIR for Combustion VentilationProviding Adequate Ventilation Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Check GAS Type InstallationInstallation Items InstallationFireplace Clearances Fireplace pilot and burner must be at least 18 above floorIf you have not installed hood, follow instruc- tions on Built-In Fireplace InstallationRoute flexible gas line through access hole in hearth base Optional Mantel InstallationRemoving Upper Louver Installing Optional Blower Accessory GA3450TACheck all gas connections for leaks. See Open lower louver door by swinging door down see Figure Installing Blower AccessoryRemove 4 screws from upper louver see . Save these screws Extension Cord For Built-In InstallationExternal Regulator With Vent Pointing Down Connecting to GAS SupplyChecking GAS Connections Connecting equipment shutoff valve to heater controlInstallation Items Needed Equipment Shutoff Valve Pressure Testing Fireplace Gas ConnectionsInstalling 9-Volt Battery in Hand-Held Remote Control Unit Installing ReceiverRemove battery cover on back of remote control unit Replace battery cover onto remote control unitRemove jumper wire from control valve see , Optional Wall Switch GWMS2 Remote-Ready Models OnlyFor Your Safety Read Before Lighting Installing LOG SET and ScreenOperating Fireplace Lighting InstructionsOperating Fireplace Manual Lighting ProcedureTo Turn OFF GAS To Appliance Thermostat Control OperationOperating Blower AUTO/OFF/ON Blower SwitchDepress control knob and light pilot with match Remote Operation Optional Hand-HeldOn/Off Series Model HRC100 Thermostat Series Model HRC200Safety Features Optional GWMS2 Wall Mounted SwitchAuto Shutoff Feature Key Pad Lock FeatureInspecting Burners Cleaning MaintenancePilot Flame Pattern Burner Flame PatternWiring Diagram Cleaning MaintenanceLOG Set CabinetObserved Problem Possible Cause Remedy TroubleshootingTroubleshooting Mote-Ready Models Only Power is low When heated, vapors fromSlight smoke or odor during Initial operation Processes and log curingGas leak. See Warning VDCFTPA, Vdcfrpa SpecificationsFirebox Models VDC Illustrated Parts BreakdownParts List Vdcftpa and Vdcftna Illustrated Parts BreakdownThermostat Models Parts List Vdcfrna and Vdcfrpa REMOTE-READY ModelsKEY THERMOSTAT-CONTROLLED Blower KIT GA3450T AccessoriesEquipment Shutoff Valve GA5010 WALL-MOUNT ON/OFF Switch AccessoriesReceiver and HAND-HELD Thermostat Remote Control KIT HRC200 Receiver and HAND-HELD Remote Control KIT HRC100Service Hints Replacement PartsTechnical Service Parts Under Warranty113133-01C Limited Warranty VENT-FREE Compact Classic Hearth Warranty InformationKeep this Warranty