A&D TM-2430-13 instruction manual Main Screen Description

Page 10

2-3 Main Screen Description

The main screen is comprised of six menus and two toolbar buttons located permanently along the top of the screen. These menus may be used to access the various features of the software. The toolbar buttons may be used to set Partial Analysis and Blood Pressure Mode parameters.

Toolbar Buttons: (Only for TM-2420/TM-2421, TM-2430)

 

Button

See

Description

 

 

 

Analysis Intervals

2-4-1 Analysis Intervals

The Analysis Intervals button may be used

 

 

 

 

to define specific “Full” and “Partial” time

 

 

 

 

intervals within an opened data file for

 

 

 

 

custom data analysis.

 

 

 

 

 

Note: Not available with the UA-767PC.

 

 

 

 

 

 

BP Mode

2-4-2 BP Mode

The BP Mode selection box may be used

 

 

 

 

to specify which blood pressure

 

 

 

 

measurement

method

(Korotkoff,

 

 

 

 

oscillometric or both) is used as the basis

 

 

 

 

for statistical and graphical analysis.

 

 

 

 

Note: This only applies to TM-2421 data

 

 

 

 

 

files.

 

 

 

 

 

 

 

 

 

 

Main Menus:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Menu

See

 

Description

 

 

 

File

2-5 File Menu

 

The File menu may be used to manage the

 

 

 

 

files stored on the hard drive or a floppy disk

 

 

 

 

and to exit the software.

 

 

 

 

 

 

 

View

2-6 View Menu

 

The View menu may be used to access the

 

 

 

 

statistical, tabular, and graphical analysis

 

 

 

 

screens.

 

 

 

 

 

 

 

 

Recorder

2-7 Recorder Menu

 

The Recorder menu may be used to

 

 

 

 

program the monitor, clear measurement

 

 

 

 

data in the monitor’s memory and to retrieve

 

 

 

 

the measurement data from the monitor.

 

 

 

 

 

 

Report

2-8 Report Menu

 

The Report menu may be used to specify

 

 

 

 

report formats and print reports.

 

 

 

 

 

 

 

Option

2-9 Options Menu

 

The Options menu may be used to set the

 

 

 

 

default

settings

and

user-defined

 

 

 

 

parameters.

 

 

 

 

 

 

 

 

Help

2-10 On-line Help

 

The Help menu may be used to view

 

 

 

 

information on software usage. Help may

 

 

 

 

also be accessed by pressing F1 when

 

 

 

 

various screens are opened or by clicking

 

 

 

 

the Help button on a screen.

 

 

 

 

 

 

 

 

 

9

Image 10
Contents TM-2430-13 Contents Troubleshooting Introduction About the Data Analysis SoftwareSymbols Monitoring Device ReviewSoftware Package Components Installing the SoftwareSafety System RequirementsCommunication Between the Monitor and the Software Connecting the TM-2420/TM-2421 to the computerGetting Started Communication Between the Monitor and the SoftwareConnecting the TM-2430 series to the computer Connecting the UA-767PC to the computer Main Screen Description Analysis Intervals BP Mode ToolbarMethod Setting Description File Menu Menu DescriptionSave As DeleteFile Merge ConvertSelect the Merge the BP data files sub-menu Exit PrintClick Open Saving a FileView Menu Summary Data display Summary Data Tab Definition Errors forBP Blood See 3-1 Measurement Errors StatusExcluding/Including BP Measurements Entering CommentsPulse Pulse Trend Linking to Trends ScreenSystolic/Diastolic Blood Pressure BP Trend Mean Arterial Blood Pressure MAP TrendBlood Pressure Trend BP Limits Delimitation, Scroll Bar and Linking Partial AnalysisSleep Scroll bar/LinkingScaling the Screen Viewing the TrendsTrend Display Positioning Trends Trend Page Setup dialog box Creating a New/Edit Trends TemplateBlood Pressure Trend Setup dialog box Correlation Plots display MAP, Mean Blood Arterial Pressure Systolic Blood PressureDiastolic Blood Pressure PulseCircadian Rhythm display HIB Analysis HIB analysis displayData retrieval. See 2-7-1 Retrieving Data from the Monitor Field DescriptionIntervals and Conditions Physician ListRecorder Menu Select the Patient Information sub-menuSelect the Recorder menu Select the Retrieve data sub-menu Retrieving Data from the MonitorClick the Retrieve Data button Clearing The Monitor’s Memory Select the Recorder menuMonitoring session is performed at the same interval for TM-2420/TM-2421 Recorder Setup dialog box 3-2 TM-2430 Series Setup Description of each mode is as followsPeriod Start Interval Example Programming the Monitor for Three 3 Periods Monitor programming exampleExample Programming the Monitor for Four 4 Periods OFF3-4 UA-767PC Setup Blood Pressure Measurement Available only with the UA-767PCReport Menu Report dialog boxReport setup dialog box Creating a New Report TemplateDeleting an Existing Report Template Saving a Default Report Template for PrintingEditing an Existing Report Template Printing an Existing Report TemplateOptions Menu Deleting an Existing Physician in the List Adding a New Physician to the ListEditing an Existing Physician in the List Trend Display See 2-6-3-3 Trend Display Positioning TrendsDefault Blood Pressure Settings dialog box Serial Port On-line HelpRecorder Type Be erased Measurement Errors1 TM-2420/TM-2421 Error Codes Well as programmed intervalsBe taped to the arm with the supplied 2 TM-2430 Series Error Codes Communication Errors Communications Error dialog boxMissing Files Reports Are Not Printing With the Desired BP ModeSummary Data / Sleep Tab Data can not be Seen Printout Examples Summary data Full and partial Text data Summary data Awake and sleep Text data Blood pressure data Text data Trend graph Blood pressure and double product Graphical data Page Page Mini report Mini report Terms Related to Blood Pressure Terms Related to StatisticsTerms Related to Biological Rhythm Mesor95% confidence interval is expressed Terms Related to the Risk Management of High Blood Pressure Memo Memo Memo