A&D TM-2430-13 instruction manual File Menu, Menu Description

Page 13

To specify the BP Mode while viewing an opened data file, complete these steps:

Step 1 Select the BP Mode box on the toolbar.

Step 2 Select the desired BP Mode used to view and analyze the opened data file.

Figure 5: BP Mode selection on toolbar

To set a default BP Mode for the software at startup, see 2-9-4 Default Settings”.

Note: The BP Mode for printed reports is assigned separately in the Report Format Setup. See 2-8Report Menu”.

2-5 File Menu

The File menu is used to manage the files stored on a hard drive or floppy disk. It may also be used to exit the software. The File menu has the following sub-menus:

Menu

Description

Open

This function is used to select a data file for viewing, modifying or

 

printing a report. After a file has been opened, the file name, patient

 

name and date of the monitoring session are displayed in the title bar

 

of the main screen

 

 

Save As

This function is used to copy a selected file to a new file with a

 

different name.

 

 

Delete

This function is used to delete a selected file.

 

 

Convert

This function is used to convert the blood pressure measurement

 

data of a data file to a format which is readable by most spreadsheet

 

applications. The converted file will have the same name as the data

 

file with a .CSV file extension.

 

 

Merge the BP data files

This function is used to merge multiple data files into one file.

 

 

Print

This function is used to print reports for one or more data files

 

according to a user-selectable report format.

 

 

Exit

This selection is used to exit the software.

 

 

12

Image 13
Contents TM-2430-13 Contents Troubleshooting About the Data Analysis Software IntroductionMonitoring Device Review SymbolsSafety Installing the SoftwareSoftware Package Components System RequirementsGetting Started Connecting the TM-2420/TM-2421 to the computerCommunication Between the Monitor and the Software Communication Between the Monitor and the SoftwareConnecting the TM-2430 series to the computer Connecting the UA-767PC to the computer Main Screen Description Toolbar Analysis Intervals BP ModeMethod Setting Description Menu Description File MenuDelete Save AsFile Merge ConvertSelect the Merge the BP data files sub-menu Click Open PrintExit Saving a FileView Menu Summary Data display Summary Data Tab Definition Errors forBP Blood Status See 3-1 Measurement ErrorsEntering Comments Excluding/Including BP MeasurementsSystolic/Diastolic Blood Pressure BP Trend Linking to Trends ScreenPulse Pulse Trend Mean Arterial Blood Pressure MAP TrendSleep Delimitation, Scroll Bar and Linking Partial AnalysisBlood Pressure Trend BP Limits Scroll bar/LinkingScaling the Screen Viewing the TrendsTrend Display Positioning Trends Creating a New/Edit Trends Template Trend Page Setup dialog boxBlood Pressure Trend Setup dialog box Correlation Plots display Diastolic Blood Pressure Systolic Blood PressureMAP, Mean Blood Arterial Pressure PulseCircadian Rhythm display HIB analysis display HIB AnalysisIntervals and Conditions Field DescriptionData retrieval. See 2-7-1 Retrieving Data from the Monitor Physician ListSelect the Patient Information sub-menu Recorder MenuSelect the Recorder menu Select the Retrieve data sub-menu Retrieving Data from the MonitorClick the Retrieve Data button Select the Recorder menu Clearing The Monitor’s MemoryMonitoring session is performed at the same interval for TM-2420/TM-2421 Recorder Setup dialog box Description of each mode is as follows 3-2 TM-2430 Series SetupPeriod Start Interval Monitor programming example Example Programming the Monitor for Three 3 PeriodsOFF Example Programming the Monitor for Four 4 PeriodsBlood Pressure Measurement Available only with the UA-767PC 3-4 UA-767PC SetupReport dialog box Report MenuCreating a New Report Template Report setup dialog boxEditing an Existing Report Template Saving a Default Report Template for PrintingDeleting an Existing Report Template Printing an Existing Report TemplateOptions Menu Editing an Existing Physician in the List Adding a New Physician to the ListDeleting an Existing Physician in the List Trend Display See 2-6-3-3 Trend Display Positioning TrendsDefault Blood Pressure Settings dialog box Serial Port On-line HelpRecorder Type 1 TM-2420/TM-2421 Error Codes Measurement ErrorsBe erased Well as programmed intervalsBe taped to the arm with the supplied 2 TM-2430 Series Error Codes Communications Error dialog box Communication ErrorsMissing Files Reports Are Not Printing With the Desired BP ModeSummary Data / Sleep Tab Data can not be Seen Printout Examples Summary data Full and partial Text data Summary data Awake and sleep Text data Blood pressure data Text data Trend graph Blood pressure and double product Graphical data Page Page Mini report Mini report Terms Related to Statistics Terms Related to Blood PressureMesor Terms Related to Biological Rhythm95% confidence interval is expressed Terms Related to the Risk Management of High Blood Pressure Memo Memo Memo