A&D TM-2430-13 instruction manual Toolbar, Analysis Intervals BP Mode

Page 11

2-4 Toolbar

There are two toolbar buttons which appear underneath the main menu bar:

(1)Analysis Intervals

(2)BP Mode

2-4-1 Analysis Intervals

The Analysis Intervals feature is used to define specific periods of time within an opened data file for custom data analysis. Two intervals, Full Analysis and Partial Analysis may be defined for each data file.

Figure 4: Analysis Intervals dialog box

To set the Analysis Intervals, complete these steps:

Step 1 Click the Analysis Intervals button on the toolbar.

Step 2 Set each item in the Full analysis interval box, using the scroll bar.

Step 3 Check a Status button in the Partial analysis interval box. When “Enabled” is checked, set each item in the box.

Step 4 Click the Save button.

Step 5 To cancel the settings, click the Cancel button.

The Partial Analysis Interval affects many of the software features including:

Summary Data

After the Partial Analysis Interval is enabled, the Partial tab in the Summary Data will be activated.

Trend Graphs

After Partial Analysis Interval is defined, the data specified within the parameters will appear in red on the Trend Graph.

Correlation Plots

After Partial Analysis parameters are defined, a second set of Correlation plots in red will appear based on the data specified within the Partial Analysis parameters.

10

Image 11
Contents TM-2430-13 Contents Troubleshooting About the Data Analysis Software IntroductionMonitoring Device Review SymbolsSystem Requirements Installing the SoftwareSafety Software Package ComponentsCommunication Between the Monitor and the Software Connecting the TM-2420/TM-2421 to the computerGetting Started Communication Between the Monitor and the SoftwareConnecting the TM-2430 series to the computer Connecting the UA-767PC to the computer Main Screen Description Toolbar Analysis Intervals BP ModeMethod Setting Description Menu Description File MenuDelete Save AsSelect the Merge the BP data files sub-menu ConvertFile Merge Saving a File PrintClick Open ExitView Menu Summary Data display BP Blood Errors forSummary Data Tab Definition Status See 3-1 Measurement ErrorsEntering Comments Excluding/Including BP MeasurementsMean Arterial Blood Pressure MAP Trend Linking to Trends ScreenSystolic/Diastolic Blood Pressure BP Trend Pulse Pulse TrendScroll bar/Linking Delimitation, Scroll Bar and Linking Partial AnalysisSleep Blood Pressure Trend BP LimitsTrend Display Positioning Trends Viewing the TrendsScaling the Screen Creating a New/Edit Trends Template Trend Page Setup dialog boxBlood Pressure Trend Setup dialog box Correlation Plots display Pulse Systolic Blood PressureDiastolic Blood Pressure MAP, Mean Blood Arterial PressureCircadian Rhythm display HIB analysis display HIB AnalysisPhysician List Field DescriptionIntervals and Conditions Data retrieval. See 2-7-1 Retrieving Data from the MonitorSelect the Patient Information sub-menu Recorder MenuClick the Retrieve Data button Retrieving Data from the MonitorSelect the Recorder menu Select the Retrieve data sub-menu Select the Recorder menu Clearing The Monitor’s MemoryMonitoring session is performed at the same interval for TM-2420/TM-2421 Recorder Setup dialog box Description of each mode is as follows 3-2 TM-2430 Series SetupPeriod Start Interval Monitor programming example Example Programming the Monitor for Three 3 PeriodsOFF Example Programming the Monitor for Four 4 PeriodsBlood Pressure Measurement Available only with the UA-767PC 3-4 UA-767PC SetupReport dialog box Report MenuCreating a New Report Template Report setup dialog boxPrinting an Existing Report Template Saving a Default Report Template for PrintingEditing an Existing Report Template Deleting an Existing Report TemplateOptions Menu Trend Display See 2-6-3-3 Trend Display Positioning Trends Adding a New Physician to the ListEditing an Existing Physician in the List Deleting an Existing Physician in the ListDefault Blood Pressure Settings dialog box Recorder Type On-line HelpSerial Port Well as programmed intervals Measurement Errors1 TM-2420/TM-2421 Error Codes Be erasedBe taped to the arm with the supplied 2 TM-2430 Series Error Codes Communications Error dialog box Communication ErrorsSummary Data / Sleep Tab Data can not be Seen Reports Are Not Printing With the Desired BP ModeMissing Files Printout Examples Summary data Full and partial Text data Summary data Awake and sleep Text data Blood pressure data Text data Trend graph Blood pressure and double product Graphical data Page Page Mini report Mini report Terms Related to Statistics Terms Related to Blood PressureMesor Terms Related to Biological Rhythm95% confidence interval is expressed Terms Related to the Risk Management of High Blood Pressure Memo Memo Memo