A&D TM-2430-13 instruction manual Introduction, About the Data Analysis Software

Page 4

1. INTRODUCTION

1-1 About the Data Analysis Software

Welcome to the Ambulatory Blood Pressure Monitor (ABPM) Data Analysis Software. This software is intended for use with the following devices.

ABPM: For diagnosing high blood pressure

1)A&D TM-2430 Series Ambulatory Blood Pressure Monitor

2)A&D TM-2420/TM-2421 Ambulatory Blood Pressure Monitor

and the TM-2020/TM-2021 Printer/Processor/Interface (hereafter referred to as "processor").

Home use monitor: For managing the blood pressure of a high blood pressure patient 3) A&D UA-767PC Digital Blood Pressure Monitor

The ABPM Data Analysis Software, that analyzes ambulatory blood pressure data, is a powerful tool for diagnosing high blood pressure and managing the blood pressure of a high blood pressure patient. The following features are incorporated in this software:

Statistical Analysis

Graphical Data

Data Conversion

Printed Reports

On-line Help

Maximum Time Period

Maximum number of readings

Statistical data may be viewed in full, partial, sleep, and awake intervals, respectively in full screen, by switching between clearly labeled tabs.

Systolic/diastolic blood pressure, mean arterial blood pressure, and pulse data are displayed graphically to quickly determine patterns or trends in the data.

Circadian rhythm and HBI analysis are displayed graphically and numerically.

The Data Convert feature automatically stores blood pressure and pulse data in standard (CSV) file format for use with popular spreadsheet programs.

Custom data report formats are easily defined and printed. “Mini-report” feature automatically prints a compact summary report.

Built-in Help feature provides context-sensitive help at any time.

Doctor Pro can analyze up to one week’s data starting from the oldest reading.

When used with the UA-767PC, Doctor Pro can analyze up to five years’ data

The maximum number of readings that Doctor Pro can process is 900.

When used with the UA-767PC, Doctor Pro can process 1827 readings.

3

Image 4
Contents TM-2430-13 Contents Troubleshooting Introduction About the Data Analysis SoftwareSymbols Monitoring Device ReviewInstalling the Software SafetySoftware Package Components System RequirementsConnecting the TM-2420/TM-2421 to the computer Getting StartedCommunication Between the Monitor and the Software Communication Between the Monitor and the SoftwareConnecting the TM-2430 series to the computer Connecting the UA-767PC to the computer Main Screen Description Analysis Intervals BP Mode ToolbarMethod Setting Description File Menu Menu DescriptionSave As DeleteFile Merge ConvertSelect the Merge the BP data files sub-menu Print Click OpenExit Saving a FileView Menu Summary Data display Summary Data Tab Definition Errors forBP Blood See 3-1 Measurement Errors StatusExcluding/Including BP Measurements Entering CommentsLinking to Trends Screen Systolic/Diastolic Blood Pressure BP TrendPulse Pulse Trend Mean Arterial Blood Pressure MAP TrendDelimitation, Scroll Bar and Linking Partial Analysis SleepBlood Pressure Trend BP Limits Scroll bar/LinkingScaling the Screen Viewing the TrendsTrend Display Positioning Trends Trend Page Setup dialog box Creating a New/Edit Trends TemplateBlood Pressure Trend Setup dialog box Correlation Plots display Systolic Blood Pressure Diastolic Blood PressureMAP, Mean Blood Arterial Pressure PulseCircadian Rhythm display HIB Analysis HIB analysis displayField Description Intervals and ConditionsData retrieval. See 2-7-1 Retrieving Data from the Monitor Physician ListRecorder Menu Select the Patient Information sub-menuSelect the Recorder menu Select the Retrieve data sub-menu Retrieving Data from the MonitorClick the Retrieve Data button Clearing The Monitor’s Memory Select the Recorder menuMonitoring session is performed at the same interval for TM-2420/TM-2421 Recorder Setup dialog box 3-2 TM-2430 Series Setup Description of each mode is as followsPeriod Start Interval Example Programming the Monitor for Three 3 Periods Monitor programming exampleExample Programming the Monitor for Four 4 Periods OFF3-4 UA-767PC Setup Blood Pressure Measurement Available only with the UA-767PCReport Menu Report dialog boxReport setup dialog box Creating a New Report TemplateSaving a Default Report Template for Printing Editing an Existing Report TemplateDeleting an Existing Report Template Printing an Existing Report TemplateOptions Menu Adding a New Physician to the List Editing an Existing Physician in the ListDeleting an Existing Physician in the List Trend Display See 2-6-3-3 Trend Display Positioning TrendsDefault Blood Pressure Settings dialog box Serial Port On-line HelpRecorder Type Measurement Errors 1 TM-2420/TM-2421 Error CodesBe erased Well as programmed intervalsBe taped to the arm with the supplied 2 TM-2430 Series Error Codes Communication Errors Communications Error dialog boxMissing Files Reports Are Not Printing With the Desired BP ModeSummary Data / Sleep Tab Data can not be Seen Printout Examples Summary data Full and partial Text data Summary data Awake and sleep Text data Blood pressure data Text data Trend graph Blood pressure and double product Graphical data Page Page Mini report Mini report Terms Related to Blood Pressure Terms Related to StatisticsTerms Related to Biological Rhythm Mesor95% confidence interval is expressed Terms Related to the Risk Management of High Blood Pressure Memo Memo Memo