A&D TM-2430-13 instruction manual Method Setting Description

Page 12

Histograms

After Partial Analysis parameters are defined, the data specified within the parameters will appear in red overlaying the Full Analysis data.

2-4-2 BP Mode

The BP Mode is used to select which blood pressure method will be used as the primary and secondary choices for displaying the blood pressure measurement data. A&D monitors employ either Korotkoff, oscillometric or dual Korotkoff and oscillometric measurement methods. If the current data file contains data from a dual system, you may choose Korotkoff, oscillometric or both methods to analyze the data.

The measurement method(s) specified in the BP Mode will be the basis for the statistical and graphical analysis performed on the opened data file. The method noted with a one (1) is the primary method and the method noted with a two (2) is the secondary method. If a primary method measurement error occurred during the monitoring session or a measurement is manually excluded (see 2-6-2-1Excluding/Including BP Measurements”), a valid measurement in the secondary method will be substituted for it with the appropriate BP Mode selection.

Method Setting

Description

Oscillometric only

This option sets the primary blood pressure choice to

 

oscillometric and disables the secondary choice. If the

 

oscillometric reading for any measurement is invalid or has

 

been excluded by the user in the BP Data List, the

 

measurement will be excluded from graphical displays and

 

statistical computations.

 

 

1: Oscillometric, 2: Korotkoff

This option sets the primary blood pressure choice to

 

oscillometric and the secondary choice to Korotkoff. If an

 

oscillometric reading is invalid, oscillometric readings will

 

be substituted with Korotkoff readings. If both readings

 

are invalid for a measurement, all data from the

 

measurement is excluded.

 

 

Korotkoff only

This option sets the primary blood pressure choice to

 

Korotkoff and disables the secondary choice. If the

 

Korotkoff reading for any measurement is invalid or has

 

been excluded by the user in the BP Data List, the

 

measurement will be excluded from graphical displays and

 

statistical computations.

 

 

1: Korotkoff, 2: Oscillometric

This option sets the primary blood pressure choice to

 

Korotkoff and the secondary choice to oscillometric. If a

 

Korotkoff reading is invalid, Korotkoff readings will be

 

substituted with oscillometric readings. If both readings

 

are invalid for a measurement, all data from the

 

measurement is excluded.

 

 

11

Image 12
Contents TM-2430-13 Contents Troubleshooting Introduction About the Data Analysis SoftwareSymbols Monitoring Device ReviewInstalling the Software SafetySoftware Package Components System RequirementsConnecting the TM-2420/TM-2421 to the computer Getting StartedCommunication Between the Monitor and the Software Communication Between the Monitor and the SoftwareConnecting the TM-2430 series to the computer Connecting the UA-767PC to the computer Main Screen Description Analysis Intervals BP Mode ToolbarMethod Setting Description File Menu Menu DescriptionSave As DeleteConvert File MergeSelect the Merge the BP data files sub-menu Print Click OpenExit Saving a FileView Menu Summary Data display Errors for Summary Data Tab DefinitionBP Blood See 3-1 Measurement Errors StatusExcluding/Including BP Measurements Entering CommentsLinking to Trends Screen Systolic/Diastolic Blood Pressure BP TrendPulse Pulse Trend Mean Arterial Blood Pressure MAP TrendDelimitation, Scroll Bar and Linking Partial Analysis SleepBlood Pressure Trend BP Limits Scroll bar/LinkingViewing the Trends Scaling the ScreenTrend Display Positioning Trends Trend Page Setup dialog box Creating a New/Edit Trends TemplateBlood Pressure Trend Setup dialog box Correlation Plots display Systolic Blood Pressure Diastolic Blood PressureMAP, Mean Blood Arterial Pressure PulseCircadian Rhythm display HIB Analysis HIB analysis displayField Description Intervals and ConditionsData retrieval. See 2-7-1 Retrieving Data from the Monitor Physician ListRecorder Menu Select the Patient Information sub-menuRetrieving Data from the Monitor Select the Recorder menu Select the Retrieve data sub-menuClick the Retrieve Data button Clearing The Monitor’s Memory Select the Recorder menuMonitoring session is performed at the same interval for TM-2420/TM-2421 Recorder Setup dialog box 3-2 TM-2430 Series Setup Description of each mode is as followsPeriod Start Interval Example Programming the Monitor for Three 3 Periods Monitor programming exampleExample Programming the Monitor for Four 4 Periods OFF3-4 UA-767PC Setup Blood Pressure Measurement Available only with the UA-767PCReport Menu Report dialog boxReport setup dialog box Creating a New Report TemplateSaving a Default Report Template for Printing Editing an Existing Report TemplateDeleting an Existing Report Template Printing an Existing Report TemplateOptions Menu Adding a New Physician to the List Editing an Existing Physician in the ListDeleting an Existing Physician in the List Trend Display See 2-6-3-3 Trend Display Positioning TrendsDefault Blood Pressure Settings dialog box On-line Help Serial PortRecorder Type Measurement Errors 1 TM-2420/TM-2421 Error CodesBe erased Well as programmed intervalsBe taped to the arm with the supplied 2 TM-2430 Series Error Codes Communication Errors Communications Error dialog boxReports Are Not Printing With the Desired BP Mode Missing FilesSummary Data / Sleep Tab Data can not be Seen Printout Examples Summary data Full and partial Text data Summary data Awake and sleep Text data Blood pressure data Text data Trend graph Blood pressure and double product Graphical data Page Page Mini report Mini report Terms Related to Blood Pressure Terms Related to StatisticsTerms Related to Biological Rhythm Mesor95% confidence interval is expressed Terms Related to the Risk Management of High Blood Pressure Memo Memo Memo