Maxon Telecom WL7-VERS. C-1K Connecting Power to Lift Typical, Hand Pendant

Page 37

13. Connect short power cable to vehicle battery as follows. Remove nut from positive (+) battery terminal connec- tor (FIG. 37-1). Connect the power cable. Reinstall nut.

POSITIVE (+) BATTERY

SHORT POWER

TERMINAL

BOLT CABLE

NUT

FAX (888) 771-7713

CONNECTING POWER TO LIFT (TYPICAL)

FIG. 37-1

POWER ON/OFF

SWITCH

14. Turn ON power ON/OFF switch on

 

pump cover to power the Lift (FIG.

 

37-2). The POWER light on hand

 

pendant should be illuminated (FIG.

 

37-3). Briefly press the FOLD button

STOWED LIFT - LH SIDE SHOWN

on hand pendant (FIG. 37-3)to pres-

surize hydraulic system. Then, remove

FIG. 37-2

remaining shipping straps.

 

UP FOLD

FOLD UNFOLD

POWER

LIGHT

HAND PENDANT

FIG. 37-3

11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116

37

PATENTS PENDING

Image 37
Contents For Patents Pending For Inside Vehicle Installation onlyREV. a Patents Pending This page Intentionally Left Blank Table of Contents Completed Lift Installation Checklist System DiagramsIntroduction Safety SummarySlauson Ave. Santa Fe Springs, CA 800 227-4116 FAX 888 Body Strength Vehicle RequirementsForce & Moment Produced by Lift on Vehicle Floor FIG Lift Footprint on Vehicle Floor Lift with 33 or 34 PlatformSafety Interlock System Electrical PowerLighting Vehicle Requirements Wheelchair Door DimensionsSide View of Stowed Lift Front View of Stowed Lift Lift DimensionsWheelchair Door Body Clearance Points 32, 40, 42, 46 & 48 Floor Heights Lift Components see Table Lift Components & TerminologyThreshold Plate Name DescriptionDecals and Decal Placement Decals for WL7-vers. C Decals and Decal Placement Serial Plate & Controller Wide Platform ANTI-SLIP & Safety StripingANTI-SLIP & Safety Striping ANTI-SLIP & Safety Striping Installation Kits Lift InstallationPreparing and Positioning the Lift Vehicle RH Side ViewPreparing and Positioning the Lift Using Template to Position Lift Using Template to Position Lift Vehicle Body Cutaway Base Plate Template Hole Pattern Base Plate Bolt Hole Pattern Mounting the LiftInstall Main Circuit Breaker Install Main Circuit Breaker ROUTE/CONNECT Cables & Hand Pendant ROUTE/CONNECT Cables & Hand Pendant Bolting Ground Cable To Vehicle Frame Ground Cable Routed from LiftConnecting Hand Pendant Cable RH Side Connection Shown Typical Location Inside Vehicle For Stowing Hand Pendant Decals and Hand Pendant Mounting on Vehicle Hand Pendant Connecting Power to Lift TypicalPlatform Lowered to Ground Level Lift AT Floor LevelHydraulic Fluid Level LH Pump Shown Checking Hydraulic Fluid LevelUNBOLTING/BOLTING Pump Cover LH Pump Shown Checking Hydraulic Fluid Level This page Intentionally Left Blank MAT Switch Adjustment if Required AdjustmentsMAT Switch Adjustment Screws Adjusting Switch LH Side of LiftPlatform Tilt Adjustment Mandatory Platform Tilt Adjustment Screws Using Backup Pump to Unfold Lift with LH Pump Inboard Switch Adjustment if RequiredPlatform AT Floor Level LH Side Shown Platform below Floor LEVEL, with Ibrs UP LH Side Shown Turning Power Switch ON/OFF LH Pump Shown Hand Pendant Entering SetupController Entering Setup Changing Controller to Spanish or English if RequiredController Language Setting English or Spanish Hand Pendant Changing Setup ModeHand Pendant Changing the Setting Controller Exiting SetupOutboard Rollstop Time Adjustment if Required Controller Setting Outboard Ramp Time Range is -7 to 10 FIG Floor Position Adjustment Mandatory Inboard Rollstop with GAP Between Base Plate Inboard Rollstop Overlaps Edge of Base PlateController Setting Floor Position Example Reading Shown FIG Floor Position AdjustmentHand Pendant Changing the Setting Inboard Threshold Rollstop Plate Hydraulic System Diagram System DiagramsElectrical System Diagram Check Lift Operation Completed Lift Installation ChecklistVehicle I.D. VIN# Wheelchair Lift SERIAL# Checked by & Date