FLOOR POSITION ADJUSTMENT (MANDATORY)
NOTE: Do the following procedure to ensure the inboard rollstop rests on threshold plate and lines up approximately with edge of base plate.
11921 Slauson Ave. Santa
1.Unfold the platform until the lights illuminate at floor level or raise the platform to floor level as shown in FIG.
EDGE OF
THRESHOLD INBOARD
PLATE ROLLSTOP
EDGE OF
BASE PLATE
PLATFORM
LIGHT
Fe Springs, CA. 90670 (800)
INBOARD ROLLSTOP LINES
UP WITH BASE PLATE
FIG. 52-1B
PLATFORM AT FLOOR LEVEL
(LH SIDE SHOWN)
FIG. 52-1A
2.Inspect the threshold plate. The edge of the inboard rollstop should line up with the edge of the base plate as shown in FIG.