INBOARD SWITCH ADJUSTMENT (IF REQUIRED)
NOTE: Do this procedure if the Controller reads “IBRS SW” when Inboard Rollstop is locked in the up position.
The adjustment is done correctly if the Controller does not read “IBRS SW” when the Inboard Rollstop is locked in the up position.
1. Position the platform at floor level | POWER |
(FIG. | SWITCH |
11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
2.Turn OFF power switch on pump cover (FIG.
3.Using the manual backup pump (FIG. 46-
2), lower the platform until inboard rollstop (IBRS) is locked in the up position (FIG. 47- 1). Refer to Operation Manual for instruc- tions to operate the manual pump.
PLATFORM AT FLOOR LEVEL
(LH SIDE SHOWN)
FIG.
RELEASE
VALVE BACKUP PUMP HANDLE
USING BACKUP PUMP TO UNFOLD
(LIFT WITH LH PUMP)
FIG.
PATENTS PENDING | 46 |