Adcom A723, A720 manual Return result depends on the control byte see table. However

Page 46

46

CHAPTER 4

Performing Advanced Functions

Following notification types can be returned when issuing the

RNTTL command:

Value

Notification Type

 

 

00

Notify On Positive Threshold.

 

 

01

Notify On Negative Threshold.

 

 

10

Notify if Out of Limits.

 

 

11

Notify if Inside the Limits.

 

 

RETURNS

The return result depends on the control byte (see table). However,

 

whatever the return result is, it includes the control byte.

REMARKS

The general behavior is that an ANLG command issued on a cer-

 

tain input channel will override any previous ANLG commands

 

affecting that channel.

REMOTE

The A723 device cannot issue ANLG commands remotely, but can

 

execute them.

EXAMPLE

For RSM

 

ANLG 0

 

9999 ANLG 0 5 5 5 5 5 5 5 5 4 4 5 5 0

 

#

 

For SSMAA (on channel 4)

 

ANLG 68

 

9999 ANLG 68 0

 

#

 

For DAN (on channel 0)

 

ANLG 160

 

9999 ANLG 160 0

 

#

 

For RNTTL (on channel 2)

ANLG 178

9999 ANLG 178 340 3900 0

#

For ENOPTR (on channel 10)

ANLG 202 1000 9999 ANLG 202 0

#

COMMANDPORT

Image 46
Contents ADC N ADC N Contents Contents Introduction What are addIT devices?Installation issues Conventions ItalicsChapter Using the Base Station Opening the packagesInstalling the base station Installing the receiverInstalling the power supply AddIT Power SupplyReplacing the fuse Configuring the softwareUsing the RTU Installing the RTU Shows an addIT RTUShows what a typical RTU field installation looks like More about the LED tool Maintaining and servicing the RTU RTU batteryConfiguring an addIT RTU in the addVANTAGE software Changing the battery Chapter Chapter Performing Advanced Functions Receiver connector Understanding connectorsDevice series RTU connectors Pins on an I/O Connector Top ViewAddIT RTU Power Connector Top View Configuring the devicesSerial communication protocol General format of a commandGeneral format of an answer Series 1 devices Using terminal commandsSET Ownid nnnn SET PMP 63 SET OwnidSET PMP bl bh SET Slot 3600SET Freq 467112500 SET Freq freq stepSET Rssi value Querying the actual configuration parameters SET RssiSeries 2 and 3 devices CmdsFreq FreqFreq 433925000 Freq 433925000 25000Slot PMP 193 CM 1 PMP 65 72193 cm SSTDEV ReplDEL Repl 5667DEL Dd mm yyyy hh mm ss si ft d1 d2 ... dn dd mm yyyy Data 5666 12/12/1998Data b1 b2 b3 ... bn Dn csFrame 38 description Data 6367 30/4/1999 Frame 39 descriptionImme DataRoute Fdev InfoTemp = internalTem p 146 900 Info 255 0 18/4/1999 21511 1.3 0 0 0 91Anlg Code Description Parameters Returns Sampling methods are defined by three bits, as follows Return result depends on the control byte see table. However A720B and A723, but see also the comments in Remote on Performing Advanced Functions Command Code Definitions Port 193 RX 6789 Port 7/5/1999 183422193 TX #7851 BA 6789 B#234 BA 15190 BVER 1.3 Blst 30/8/2001 160341VER VER 2.0Notifications Device descriptors and storage handler Returned errors listCommand line interpreter Real time clockNotifications Chapter Appendix. Specifications Parameter Min Typ Max UnitTransmitter all measurements made on a 50 Ω resistive load Chapter Chapter Index INFO, 41 OWNID, 26 PMP PMP What a base station contains Xmit Credits Credits and ColophonColophon