Adcom A723 Returned errors list, Command line interpreter, Device descriptors and storage handler

Page 54

54

CHAPTER 4

Performing Advanced Functions

Returned errors list

Following are error messages you might get.

Command line interpreter

1 — nonexistent command

2 — command line buffer overflow (input line too long)

3 — internal error

4 — reserved

5 — missing or false parameters in command

6 — operation not implemented

Device descriptors and storage handler

10 — device not found (attempt to perform a command on a nonexistent device)

11 — device already exists

12 — reserved

13 — no more space for descriptors (too many devices)

14 — no more records for the specified device

15 — temporary communication break, no more data (the last request was not successful)

16 — time-out (the handler blocked or is busy)

17 — internal error

18 — attempt to insert a reserved device ID number (0 or 65535)

Real time clock

20 — incorrect time supplied (conversion to time_t was not possible)

Radio interface

30 — error at receive (CRC, etc.)

31 — unexpected frame received

32 — wrong length

33 — reserved

34 — reserved

35 — time-out (remote device not responding)

Image 54
Contents ADC N ADC N Contents Contents Introduction What are addIT devices?Installation issues Conventions ItalicsChapter Using the Base Station Opening the packagesInstalling the base station Installing the receiverInstalling the power supply AddIT Power SupplyReplacing the fuse Configuring the softwareUsing the RTU Installing the RTU Shows an addIT RTUShows what a typical RTU field installation looks like More about the LED tool RTU battery Maintaining and servicing the RTUConfiguring an addIT RTU in the addVANTAGE software Changing the battery Chapter Chapter Performing Advanced Functions Understanding connectors Receiver connectorDevice series RTU connectors Pins on an I/O Connector Top ViewAddIT RTU Power Connector Top View Configuring the devicesGeneral format of a command Serial communication protocolGeneral format of an answer Using terminal commands Series 1 devicesSET Ownid nnnn SET PMP 63 SET OwnidSET PMP bl bh SET Slot 3600SET Freq freq step SET Freq 467112500SET Rssi value Querying the actual configuration parameters SET RssiSeries 2 and 3 devices CmdsFreq FreqFreq 433925000 Freq 433925000 25000Slot PMP 193 CM 1 PMP 65 72193 cm SSTDEV ReplRepl 5667 DELDEL Dd mm yyyy hh mm ss si ft d1 d2 ... dn dd mm yyyy Data 5666 12/12/1998Data b1 b2 b3 ... bn Dn csFrame 38 description Data 6367 30/4/1999 Frame 39 descriptionData ImmeRoute Fdev InfoTemp = internalTem p Info 255 0 18/4/1999 21511 1.3 0 0 0 91 146 900Anlg Code Description Parameters Returns Sampling methods are defined by three bits, as follows Return result depends on the control byte see table. However A720B and A723, but see also the comments in Remote on Performing Advanced Functions Command Code Definitions Port 6789 Port 7/5/1999 183422 193 RX193 TX #7851 BA 6789 B#234 BA 15190 BVER 1.3 Blst 30/8/2001 160341VER VER 2.0Notifications Device descriptors and storage handler Returned errors listCommand line interpreter Real time clockNotifications Chapter Appendix. Specifications Parameter Min Typ Max UnitTransmitter all measurements made on a 50 Ω resistive load Chapter Chapter Index INFO, 41 OWNID, 26 PMP PMP What a base station contains Xmit Credits and Colophon CreditsColophon