CHAPTER 4

Performing Advanced Functions

Table 5. Command Code Definitions (Continued)

Code

Description

Parameters

Returns

 

 

 

 

0100

RBV – Read the specified bit.

The port number.

Bit value and the result

 

 

 

(OK or ERROR).

 

 

 

 

0101

RNS – Read the notificationa status. If no notifi-

The port number.

Returns the time of the

 

cation was pending, this command should

 

last port change in stan-

 

return an error. If one was pending, the notifica-

 

dard time format and the

 

tion is cleared.

 

result (OK or ERROR).

 

 

 

 

0110

DNOPC – Disable Notify On Port Change.

The port number.

Result (OK or ERROR).

 

 

 

 

0111

ENOPC – Enable Notify On Port Change.

The port number.

Result (OK or ERROR).

 

 

 

 

1000

RPNNER – Read the Pending Notifications and

None.

Two 16-bit integers (first

 

the Notification Enable Register. This command

 

the PN and then the NE

 

returns the 16-bit Pending Notifications and the

 

register) and the result

 

Notification Enable Registers; the Port Number

 

(OK or ERROR).

 

has no significance for this command.

 

 

 

 

 

 

1001

CB – Clear the specified bit.

The port number.

Result (OK or ERROR).

 

 

 

 

1010

SB – Set the specified bit.

The port number.

Result (OK or ERROR).

 

 

 

 

1011

XB – Exclusive Or the specified bit.

The port number.

Result (OK or ERROR).

 

 

 

 

1100

MFR – Monostable function, start with the speci-

The port number,

Result (OK or ERROR)

 

fied bit in OFF state (reset).

the OFF and the

 

 

 

ON times (in sec-

 

 

 

onds), both as 16-

 

 

 

bit integers.

 

 

 

 

 

1101

MFS – Monostable function, start with the speci-

The port number,

Result (OK or ERROR).

 

fied bit in ON state (set).

the OFF and the

 

 

 

ON times (in sec-

 

 

 

onds), both as 16-

 

 

 

bit integers.

 

 

 

 

 

1110

MVFR – Multivibrator function, start with the

The port number,

Result (OK or ERROR).

 

specified bit in OFF state (reset).

the OFF and the

 

 

 

ON times (in sec-

 

 

 

onds), both as 16-

 

 

 

bit integers.

 

 

 

 

 

1111

MVFS – Multivibrator function, start with the

The port number,

Result (OK or ERROR).

 

specified bit in ON state (set).

the OFF and the

 

 

 

ON times (in sec-

 

onds), both as 16- bit integers.

Image 48
Contents ADC N ADC N Contents Contents Introduction What are addIT devices?Installation issues Conventions ItalicsChapter Using the Base Station Opening the packagesInstalling the base station Installing the receiverInstalling the power supply AddIT Power SupplyReplacing the fuse Configuring the softwareUsing the RTU Installing the RTU Shows an addIT RTUShows what a typical RTU field installation looks like More about the LED tool RTU battery Maintaining and servicing the RTUConfiguring an addIT RTU in the addVANTAGE software Changing the battery Chapter Chapter Performing Advanced Functions Understanding connectors Receiver connectorDevice series RTU connectors Pins on an I/O Connector Top ViewAddIT RTU Power Connector Top View Configuring the devicesGeneral format of a command Serial communication protocolGeneral format of an answer Using terminal commands Series 1 devicesSET Ownid nnnn SET Ownid SET PMP bl bhSET PMP 63 SET Slot 3600SET Freq freq step SET Freq 467112500SET Rssi value Querying the actual configuration parameters SET RssiSeries 2 and 3 devices CmdsFreq Freq 433925000Freq Freq 433925000 25000Slot PMP PMP 65 72 193 cm193 CM 1 SSTDEV ReplRepl 5667 DELDEL Data 5666 12/12/1998 Data b1 b2 b3 ... bnDd mm yyyy hh mm ss si ft d1 d2 ... dn dd mm yyyy Dn csFrame 38 description Data 6367 30/4/1999 Frame 39 descriptionData ImmeRoute Fdev InfoTemp = internalTem p Info 255 0 18/4/1999 21511 1.3 0 0 0 91 146 900Anlg Code Description Parameters Returns Sampling methods are defined by three bits, as follows Return result depends on the control byte see table. However A720B and A723, but see also the comments in Remote on Performing Advanced Functions Command Code Definitions Port 6789 Port 7/5/1999 183422 193 RX193 TX 6789 B #234 BA#7851 BA 15190 BBlst 30/8/2001 160341 VERVER 1.3 VER 2.0Notifications Returned errors list Command line interpreterDevice descriptors and storage handler Real time clockNotifications Chapter Appendix. Specifications Parameter Min Typ Max UnitTransmitter all measurements made on a 50 Ω resistive load Chapter Chapter Index INFO, 41 OWNID, 26 PMP PMP What a base station contains Xmit Credits and Colophon CreditsColophon