Page 33

 

CHAPTER 4

 

Using terminal commands

APPLIES TO

A720, A720B, A723

DESCRIPTION

Sets/returns the input storing and sampling intervals.

PARAMETERS

storage represents the time (in seconds) elapsed between two

 

slots stored in the internal memory, while samples represents the

 

numbers of samples used to build the average that will be stored.

RETURNS

The interval and rate.

REMARKS

The default storage is 900 (15 minutes) and samples is 3 (3 sam-

 

ples per quarter of an hour).

REMOTE

Yes, SET only.

EXAMPLE

SLOT 900 3

 

193 SLOT 0

 

#

 

SLOT

 

193 SLOT 900 3 0

 

#

 

Note: The A720B base station needs only the rate. For consis-

 

tency, however, it accepts both parameters and discards the

 

one it doesn’t need.

33

COMMAND

PMP

APPLIES TO

A720, A720B, A723

DESCRIPTION

Sets/returns the node’s Power Management Parameters (switches

 

on/off the battery charge).

PARAMETERS

The lower (switch on) and the higher limit (switch off), both in volts

 

x 10. Standard Values are 65 (for 6.5 Volts) for switch on and 72 (for

 

7.2 Volts) for switch off.

RETURNS

The lower (switch off) and the higher limit (switch on), both in volts

 

x 10.

REMARKS

GET/SET.

REMOTE

Yes, SET only.

EXAMPLE

PMP 65 72

 

193 PMP 0

 

#

Image 33
Contents ADC N ADC N Contents Contents What are addIT devices? IntroductionInstallation issues Italics ConventionsChapter Opening the packages Using the Base StationInstalling the receiver Installing the base stationAddIT Power Supply Installing the power supplyConfiguring the software Replacing the fuseUsing the RTU Shows an addIT RTU Installing the RTUShows what a typical RTU field installation looks like More about the LED tool RTU battery Maintaining and servicing the RTUConfiguring an addIT RTU in the addVANTAGE software Changing the battery Chapter Chapter Performing Advanced Functions Understanding connectors Receiver connectorDevice series Pins on an I/O Connector Top View RTU connectorsConfiguring the devices AddIT RTU Power Connector Top ViewGeneral format of a command Serial communication protocolGeneral format of an answer Using terminal commands Series 1 devicesSET Ownid nnnn SET PMP bl bh SET OwnidSET PMP 63 SET Slot 3600SET Freq freq step SET Freq 467112500SET Rssi value SET Rssi Querying the actual configuration parametersCmds Series 2 and 3 devicesFreq 433925000 FreqFreq Freq 433925000 25000Slot PMP 193 cm PMP 65 72193 CM 1 SSTRepl DEVRepl 5667 DELDEL Data b1 b2 b3 ... bn Data 5666 12/12/1998Dd mm yyyy hh mm ss si ft d1 d2 ... dn dd mm yyyy Dn csFrame 38 description Frame 39 description Data 6367 30/4/1999Data ImmeRoute Info FdevTemp = internalTem p Info 255 0 18/4/1999 21511 1.3 0 0 0 91 146 900Anlg Code Description Parameters Returns Sampling methods are defined by three bits, as follows Return result depends on the control byte see table. However A720B and A723, but see also the comments in Remote on Performing Advanced Functions Command Code Definitions Port 6789 Port 7/5/1999 183422 193 RX193 TX #234 BA 6789 B#7851 BA 15190 BVER Blst 30/8/2001 160341VER 1.3 VER 2.0Notifications Command line interpreter Returned errors listDevice descriptors and storage handler Real time clockNotifications Chapter Parameter Min Typ Max Unit Appendix. SpecificationsTransmitter all measurements made on a 50 Ω resistive load Chapter Chapter Index INFO, 41 OWNID, 26 PMP PMP What a base station contains Xmit Credits and Colophon CreditsColophon