Adcom A720, A723 manual Performing Advanced Functions

Page 21

21

Chapter 4. Performing Advanced Functions

With the appropriate knowledge, you can configure the addIT devices in the field by using a hyperterminal window. To configure the RTU, you will need a special serial cable adapter (not supplied, available from Adcon).

CAUTION Do not try to configure your addIT devices if you are not sure what to do—the unit may not communicate with the remote measuring station or function with the addVANTAGE software.

WARNING Tampering with parameters for the addIT devices may void your warranty or damage the device. In general, the commands described in this chapter are intended for technical support staff and users with a great deal of highly technical hardware and software experience.

In the system architecture, the base station and RTU are both con- sidered to be nodes. The base station is called the master node, or master, while the RTU is called the slave node, or slave.

Image 21
Contents ADC N ADC N Contents Contents What are addIT devices? IntroductionInstallation issues Italics ConventionsChapter Opening the packages Using the Base StationInstalling the receiver Installing the base stationAddIT Power Supply Installing the power supplyConfiguring the software Replacing the fuseUsing the RTU Shows an addIT RTU Installing the RTUShows what a typical RTU field installation looks like More about the LED tool RTU battery Maintaining and servicing the RTUConfiguring an addIT RTU in the addVANTAGE software Changing the battery Chapter Chapter Performing Advanced Functions Understanding connectors Receiver connectorDevice series Pins on an I/O Connector Top View RTU connectorsConfiguring the devices AddIT RTU Power Connector Top ViewGeneral format of a command Serial communication protocolGeneral format of an answer Using terminal commands Series 1 devicesSET Ownid nnnn SET PMP bl bh SET OwnidSET PMP 63 SET Slot 3600SET Freq freq step SET Freq 467112500SET Rssi value SET Rssi Querying the actual configuration parametersCmds Series 2 and 3 devicesFreq 433925000 FreqFreq Freq 433925000 25000Slot PMP 193 cm PMP 65 72193 CM 1 SSTRepl DEVRepl 5667 DELDEL Data b1 b2 b3 ... bn Data 5666 12/12/1998Dd mm yyyy hh mm ss si ft d1 d2 ... dn dd mm yyyy Dn csFrame 38 description Frame 39 description Data 6367 30/4/1999Data ImmeRoute Info FdevTemp = internalTem p Info 255 0 18/4/1999 21511 1.3 0 0 0 91 146 900Anlg Code Description Parameters Returns Sampling methods are defined by three bits, as follows Return result depends on the control byte see table. However A720B and A723, but see also the comments in Remote on Performing Advanced Functions Command Code Definitions Port 6789 Port 7/5/1999 183422 193 RX193 TX #234 BA 6789 B#7851 BA 15190 BVER Blst 30/8/2001 160341VER 1.3 VER 2.0Notifications Command line interpreter Returned errors listDevice descriptors and storage handler Real time clockNotifications Chapter Parameter Min Typ Max Unit Appendix. SpecificationsTransmitter all measurements made on a 50 Ω resistive load Chapter Chapter Index INFO, 41 OWNID, 26 PMP PMP What a base station contains Xmit Credits and Colophon CreditsColophon