KitchenAid W101871170D installation instructions Wall Installations, Roof Installations

Page 19

2.Lift up the panel from the bottom mounting channel.

B

A

A. Blower mounting channel

B.Panel

3.Reinstall both panels to the opposite side of the vent box panel from which they were removed. Place bottom tab of the panel into the bottom mounting channel.

B

A

A. Blower mounting channel

B.Panel

4.Tilt panel top tab so it is flush with the vent box panel and position it under the tip mounting bracket. Slide bracket into the “Z” slots and tighten the 2 hex/slotted head screws to secure.

5.See “Complete Installation” section.

Complete Installation

1.Remove the Phillips-head screw attaching the terminal box cover and remove cover.

A

A. Terminal box cover

Remove either the back or bottom knockout inside the terminal box and install a UL listed or CSA approved conduit connector.

NOTE: Power supply cable needed between exterior blower assembly and blower box is not provided.

Flexible armored or nonmetallic cable must be used. A

½" (12.7 cm) UL listed or CSA approved strain relief must be provided at each end of the power supply cable.

2.Determine the location where the exterior blower box will be located. Cut opening in roof or wall for vent system to exterior blower. Install exterior blower according to instructions supplied with the blower kit.

Wall Installations:

Use caulking compound between mounting flange and wall.

Roof Installations:

Follow standard roofing procedures. Refer to the “Roof Installations” section of the Exterior Blower Installation Instructions.

The flashing sheet should be centered over the roof opening.

Lower edge of flashing should lie on top of shingles and upper edge underneath shingles.

Seal assembly between roof, fan and flashing with roofing mastic to avoid leaks.

3.Using 2 or more people, insert the downdraft vent into the countertop cutout. Position downdraft vent so it is centered in cutout and parallel to edge of cutout. Check that downdraft vent is level vertically. Then fasten lower support legs to the cabinet floor with screws.

19

Image 19
Contents Retractable POP-UP Downdraft Vent System Table DES Matières Table of ContentsYour safety and the safety of others are very important Vent System SafetyTools and Parts Installation RequirementsLocation Requirements Cabinet Dimensions Product DimensionsCountertop Cutout Dimensions Chart Countertop Cutout DimensionsVenting Requirements Electrical RequirementsRecommended vent system length Front Standard Mounted Blower Motor Installation Instructions INTERIOR-MOUNTED Vent MotorVenting Methods Island LocationVent Piece Cm Round Install Vent SystemExample Vent System Maximum Length of Vent SystemBottom venting Determine which direction is best for your installationLeft or right venting Rear Venting Plug in the wire connector to the blower motor Lift up the panel from the bottom mounting channel Rear Mounting Blower MotorInterior Mounted Motor Complete InstallationMake Electrical Connections Island location front vent Installation Instructions EXTERIOR-MOUNTED Vent MotorCheck Operation Island location rear ventMaximum Length of Vent System 10 25.4 cm round 40 ft 12.2 m Roof VentingFront venting Roof Installations Wall InstallationsElectrical Connection Check Operation Surface of Downdraft Vent Vent System USEVent System Care Operating Downdraft Vent5x20 800 mA Time Delay Wiring DiagramCanada Assistance or ServiceAccessories U.S.AThis limited warranty does not cover Kitchenaid Ventilation WarrantyPage Avertissement Importantes Instructions DE Sécurité Exigences demplacement Exigences DinstallationOutillage et pièces Modèle avec ventilateur monté à lextérieur Dimensions du produitDimensions du placard Modèle avec ventilateur monté à lintérieurTableau des dimensions de l’ouverture du plan de travail Plan de travail Dimensions des ouvertures à découperSpécifications électriques Longueur recommandée pour le système d’extractionExigences concernant lévacuation Ventilateur monté à larrière Instructions Dinstallation Ventilateur Monté À LintérieurConfiguration de cuisine en îlot Méthodes dextractionExemple de système d’extraction Installation du système d’extractionComposant Système de diamètre 6 15,2 cm Évacuation par le fond Déterminer la meilleure direction pour l’installationÉvacuation par le côté gauche ou par le côté droit Évacuation par l’arrière Vis 4 raccord de conduit d’évacuation Montage du ventilateur à larrière Profilé de montage du ventilateur Panneau Raccordements électriques Achever linstallationContrôle du fonctionnement Composant Conduit de diamètre 10 25,4 cm Instructions Dinstallation Ventilateur Monté À LextérieurMéthodes d’extraction Décharge à travers le toitVentilateur externe Conduit droit Coudes à Évacuation par larrière Évacuation par lavantSortie murale Raccordement électriqueSortie à travers le toit Contrôle du fonctionnement Lorsque la cuisson est terminée Utilisation DU Système DextractionUtilisation du système dextraction UtilisationSurface du système dextraction Entretien DU Système DextractionFiltres Fusible temporisé, 5x20 800 mA Schéma DE CâblageAu Canada Assistance OU ServiceAccessoires Aux États-UnisLa présente garantie limitée ne couvre pas Garantie DU Système DE Ventilation KitchenaidAll rights reserved W10187117D