4.Attach 1 undercounter bracket on front upper right corner of downdraft vent with slot over vent mounting hole and flange against countertop. Attach other bracket to left side of the downdraft vent. Drill starter holes through undercounter mounting brackets into the underside of the countertop. Insert appropriate length screws into holes and tighten brackets to the countertop.
B
C
A
A. When attaching undercounter bracket to underside of countertop, make sure that the screw length will not go through countertop when tightened.
B.Backsplash
C.Countertop
Electrical Connection
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1.Disconnect power.
2.Feed the home power supply cable through the conduit connector and into the terminal box.
3.Remove vent box knockout and install a UL listed or CSA approved conduit connector. Feed
| J | I |
|
| H |
A |
|
|
|
| G |
B |
| F |
|
| |
C | D | E |
|
A. Green or green and yellow ground wires B. Green ground screw
C. Blue wires
D. UL listed wire connector E. Brown wires
F. Downdraft vent wiring G. Black wires
H. White wires
I. UL listed or CSA approved conduit and connector, (Home power supply cable).
J. UL listed or CSA approved conduit and connector,
WARNING
Fire Hazard
Electrically ground the blower.
Use copper wire.
Connect ground wire to green ground screw in terminal box.
Failure to do so can result in death, fire, or electrical shock.
4.Attach the green (or green and yellow) ground wires from the home power supply cable and the
IMPORTANT: Exterior vent motor wires must be connected in the terminal box as shown.
5.Connect the 2 blue wires together using UL listed wire connectors.
6.Connect the 2 brown wires together using UL listed wire connectors.
20