KitchenAid W101871170D Install Vent System, Example Vent System, Maximum Length of Vent System

Page 9

Maximum Length of Vent System

Vent

Length

 

 

6" (15.2 cm) round

35 ft (8.9 m)

 

 

3¹⁄₄" x 10" (8.3 cm x 25.4 cm)

35 ft (8.9 m)

 

 

To calculate the length of the system you need, add the equivalent feet (meters) for each vent piece used in the system.

Vent Piece

6" (15.2 cm) Round

45° elbow

2.5 ft

 

(0.8 m)

 

 

90° elbow

5.0 ft

 

(1.5 m)

 

 

6" (15.2 cm)

0.0 ft

wall cap

(0.0 m)

 

 

3¹⁄₄" x 10" (8.3 cm x 25.4 cm)

4.5 ft

to 6" (15.2 cm) transition

(1.4 m)

 

 

6" (15.2 cm) to 3¹⁄₄" x 10"

1 ft

(8.3 cm x 25.4 cm) transition

(0.3 m)

 

 

3¹⁄₄" x 10" (8.3 cm x 25.4 cm)

5.0 ft

to 6" (15.2 cm) 90° elbow

(1.5 m)

transition

 

 

 

6" (15.2 cm) to 3¹⁄₄" x 10"

5.0 ft

(8.3 cm x 25.4 cm) 90° elbow

(1.5 m)

transition

 

Example Vent System

C

6 ft

(1.8 m)

A B

2 ft (0.6 m)

D

A. Blower motor

B.Transition

C.90° elbows

D.6" backdraft damper (supplied)

The following example falls within the maximum vent length of 35 ft (8.9 m).

2

- 90° elbow

= 10.0 ft (3 m)

1

- wall cap

= 0.0 ft (0.0 m)

8 ft (2.4 m) straight

= 8.0 ft (2.4 m)

Transition

= 4.5 ft (1.4 cm)

 

 

Length of 6" (15.2 cm) system

= 22.5 ft (6.8 m)

Install Vent System

WARNING

Excessive Weight Hazard

Use two or more people to move and install downdraft vent.

Failure to do so can result in back or other injury.

1.Place cardboard or similar material on top of a flat surface where you can easily assemble the downdraft vent system.

2.Remove parts packages, downdraft vent and blower box from the carton.

3.Remove all shipping materials, tape and film from the downdraft vent and blower box.

4.Remove screws from each side of the vent. Attach the left and right side overcounter support brackets to the downdraft vent and push up to align the screw holes. Use screws to secure the brackets.

A

C

B

A. Overcounter support bracket

B. Blower motor box

C. Overcounter support bracket screw

5.Attach the left and right side end caps to the downdraft vent. Place the end cap upon the overcounter support, slide the tab into the slot and snap into place over the plastic tabs.

A

A. End cap

9

Image 9
Contents Retractable POP-UP Downdraft Vent System Table DES Matières Table of ContentsYour safety and the safety of others are very important Vent System SafetyInstallation Requirements Tools and PartsLocation Requirements Cabinet Dimensions Product DimensionsCountertop Cutout Dimensions Chart Countertop Cutout DimensionsElectrical Requirements Venting RequirementsRecommended vent system length Venting Methods Installation Instructions INTERIOR-MOUNTED Vent MotorIsland Location Front Standard Mounted Blower MotorExample Vent System Install Vent SystemMaximum Length of Vent System Vent Piece Cm RoundDetermine which direction is best for your installation Bottom ventingLeft or right venting Rear Venting Plug in the wire connector to the blower motor Lift up the panel from the bottom mounting channel Rear Mounting Blower MotorInterior Mounted Motor Complete InstallationMake Electrical Connections Check Operation Installation Instructions EXTERIOR-MOUNTED Vent MotorIsland location rear vent Island location front ventMaximum Length of Vent System 10 25.4 cm round 40 ft 12.2 m Roof VentingFront venting Roof Installations Wall InstallationsElectrical Connection Check Operation Vent System Care Vent System USEOperating Downdraft Vent Surface of Downdraft Vent5x20 800 mA Time Delay Wiring DiagramAccessories Assistance or ServiceU.S.A CanadaThis limited warranty does not cover Kitchenaid Ventilation WarrantyPage Avertissement Importantes Instructions DE Sécurité Exigences Dinstallation Exigences demplacementOutillage et pièces Dimensions du placard Dimensions du produitModèle avec ventilateur monté à lintérieur Modèle avec ventilateur monté à lextérieurTableau des dimensions de l’ouverture du plan de travail Plan de travail Dimensions des ouvertures à découperLongueur recommandée pour le système d’extraction Spécifications électriquesExigences concernant lévacuation Configuration de cuisine en îlot Instructions Dinstallation Ventilateur Monté À LintérieurMéthodes dextraction Ventilateur monté à larrièreInstallation du système d’extraction Exemple de système d’extractionComposant Système de diamètre 6 15,2 cm Déterminer la meilleure direction pour l’installation Évacuation par le fondÉvacuation par le côté gauche ou par le côté droit Évacuation par l’arrière Vis 4 raccord de conduit d’évacuation Montage du ventilateur à larrière Profilé de montage du ventilateur Panneau Raccordements électriques Achever linstallationContrôle du fonctionnement Méthodes d’extraction Instructions Dinstallation Ventilateur Monté À LextérieurDécharge à travers le toit Composant Conduit de diamètre 10 25,4 cmVentilateur externe Conduit droit Coudes à Évacuation par larrière Évacuation par lavantRaccordement électrique Sortie muraleSortie à travers le toit Contrôle du fonctionnement Utilisation du système dextraction Utilisation DU Système DextractionUtilisation Lorsque la cuisson est terminéeEntretien DU Système Dextraction Surface du système dextractionFiltres Fusible temporisé, 5x20 800 mA Schéma DE CâblageAccessoires Assistance OU ServiceAux États-Unis Au CanadaLa présente garantie limitée ne couvre pas Garantie DU Système DE Ventilation KitchenaidAll rights reserved W10187117D