KitchenAid W101871170D installation instructions Check Operation

Page 21

7.Connect the 2 white wires together using UL listed wire connectors.

8.Connect the 2 black wires together using UL listed wire connectors.

9.Tighten conduit connector clamp screws.

10.Replace the terminal box cover and secure with screw.

11.Reconnect power.

Check Operation

1.Remove the vent filter shipping bracket screws and bracket.

A

B

A. Vent filter shipping bracket

B.Screws

2.Push and hold the button on the top of the downdraft vent for a few seconds. The retractable section of the downdraft vent will rise. The blower will start immediately if the blower control knob is set to an “on” position.

3.Position the top trim over the retractable section and snap trim into place.

Trim kits for matching your cooktop color are available from your dealer.

For information on ordering, see the “Assistance or Service” section.

B

A

C

E

D

A. Top trim

B. ON/OFF button

C. Blower control slider

D. End cap

E. Filter or filters depending on model

4.Slide the control slider on the side of the vent to check the speed of the blower.

If the blower does not operate:

Check that filter or filters are pressed in as far as they will go.

Check that circuit breaker has not tripped or a household fuse blown.

Check downdraft vent fuse located under power board.

5.Connect vent system to 10" (25.4 cm) round vent collar plate.

Position vent to avoid wall studs and floor joists. Complete all vent work. Use clamps to seal all joints.

Vertical vent for wall-mounted installations should pitch down slightly toward the vent to allow moisture to run outside.

6.Install cooktop according to manufacturer’s instructions. Check that rear of cooktop overlaps edge of retractable downdraft vent by ³⁄₈" (9.5 mm). See “Countertop Cutout Dimensions” in the “Location Requirements” section.

NOTE: To get the most efficient use from your new retractable downdraft vent, read the “Vent System Use” section.

21

Image 21
Contents Retractable POP-UP Downdraft Vent System Table DES Matières Table of ContentsYour safety and the safety of others are very important Vent System SafetyInstallation Requirements Tools and PartsLocation Requirements Cabinet Dimensions Product DimensionsCountertop Cutout Dimensions Chart Countertop Cutout DimensionsElectrical Requirements Venting RequirementsRecommended vent system length Venting Methods Installation Instructions INTERIOR-MOUNTED Vent MotorIsland Location Front Standard Mounted Blower MotorExample Vent System Install Vent SystemMaximum Length of Vent System Vent Piece Cm RoundDetermine which direction is best for your installation Bottom ventingLeft or right venting Rear Venting Plug in the wire connector to the blower motor Lift up the panel from the bottom mounting channel Rear Mounting Blower MotorInterior Mounted Motor Complete InstallationMake Electrical Connections Check Operation Installation Instructions EXTERIOR-MOUNTED Vent MotorIsland location rear vent Island location front ventMaximum Length of Vent System 10 25.4 cm round 40 ft 12.2 m Roof VentingFront venting Roof Installations Wall InstallationsElectrical Connection Check Operation Vent System Care Vent System USEOperating Downdraft Vent Surface of Downdraft Vent5x20 800 mA Time Delay Wiring DiagramAccessories Assistance or ServiceU.S.A CanadaThis limited warranty does not cover Kitchenaid Ventilation WarrantyPage Avertissement Importantes Instructions DE Sécurité Exigences Dinstallation Exigences demplacementOutillage et pièces Dimensions du placard Dimensions du produitModèle avec ventilateur monté à lintérieur Modèle avec ventilateur monté à lextérieurTableau des dimensions de l’ouverture du plan de travail Plan de travail Dimensions des ouvertures à découperLongueur recommandée pour le système d’extraction Spécifications électriquesExigences concernant lévacuation Configuration de cuisine en îlot Instructions Dinstallation Ventilateur Monté À LintérieurMéthodes dextraction Ventilateur monté à larrièreInstallation du système d’extraction Exemple de système d’extractionComposant Système de diamètre 6 15,2 cm Déterminer la meilleure direction pour l’installation Évacuation par le fondÉvacuation par le côté gauche ou par le côté droit Évacuation par l’arrière Vis 4 raccord de conduit d’évacuation Montage du ventilateur à larrière Profilé de montage du ventilateur Panneau Raccordements électriques Achever linstallationContrôle du fonctionnement Méthodes d’extraction Instructions Dinstallation Ventilateur Monté À LextérieurDécharge à travers le toit Composant Conduit de diamètre 10 25,4 cmVentilateur externe Conduit droit Coudes à Évacuation par larrière Évacuation par lavantRaccordement électrique Sortie muraleSortie à travers le toit Contrôle du fonctionnement Utilisation du système dextraction Utilisation DU Système DextractionUtilisation Lorsque la cuisson est terminéeEntretien DU Système Dextraction Surface du système dextractionFiltres Fusible temporisé, 5x20 800 mA Schéma DE CâblageAccessoires Assistance OU ServiceAux États-Unis Au CanadaLa présente garantie limitée ne couvre pas Garantie DU Système DE Ventilation KitchenaidAll rights reserved W10187117D