Toshiba SL-9000-LSB owner manual Safety Summary, Meanings of Each Symbol

Page 6

Safety Summary

Safety Summary

Personal safety in handling or maintaining the equipment is extremely important. Warnings and Cautions necessary for safe handling are included in this manual. All warnings and cautions contained in this manual should be read and understood before handling or maintaining the equipment.

Do not attempt to effect repairs or modifications to this equipment. If a fault occurs that cannot be rectified using the procedures described in this manual, turn off the power, unplug the machine, then contact your authorized TOSHIBA TEC representative for assistance.

Meanings of Each Symbol

This symbol indicates warning items (including cautions). Specific warning contents are drawn inside the symbol. (The symbol on the left indicates a general caution.)

This symbol indicates prohibited actions (prohibited items). Specific prohibited contents are drawn inside or near the symbol. (The symbol on the left indicates “no disassembling”.)

This symbol indicates actions which must be performed. Specific instructions are drawn inside or near the symbol.

(The symbol on the left indicates “disconnect the power cord plug from the outlet”.)

 

 

This indicates that there is the risk of death or serious injury if the

WARNING machines are improperly handled contrary to this indication.

Any other than the

 

Do not use voltages other than the

Prohibited

 

Do not plug in or unplug the power

specified AC voltage

 

 

voltage (AC) specified on the rating

cord plug with wet hands as this may

is prohibited.

 

 

plate, as this may cause fire or

 

cause electric shock.

 

electric shock.

 

 

 

Prohibited

 

If the machines share the same

Prohibited

 

 

Do not place metal objects or

 

 

 

 

outlet with any other electrical

water-filled containers such as flower

 

 

 

appliances which consume large

 

vases, flower pots or mugs, etc. on

 

amounts of power, the voltage will

 

top of the machines. If metal objects

 

fluctuate widely each time these

 

or spilled liquid enter the machines,

 

appliances operate. Be sure to

 

this may cause fire or electric

 

provide an exclusive outlet for the

 

shock.

 

machine as this may cause the

 

 

 

 

 

machines to malfunction.

 

 

 

 

 

 

 

 

 

 

 

Prohibited

 

Do not insert or drop metal,

Prohibited

 

 

Do not scratch, damage or modify

 

 

 

 

 

 

flammable or other foreign objects into

the power cords. Also, do not place

 

 

 

the machines through the ventilation

 

heavy objects on, pull on, or exces-

 

slits, as this may cause fire or electric

 

sively bend the cords, as this may

 

shock.

 

cause fire or electrical shock.

Disconnect

 

If the machines are dropped or their

Disconnect

 

Continued use of the machines in an

 

 

the plug.

cabinets damaged, first turn off the

the plug.

abnormal condition such as when the

 

power switches and disconnect the

 

machines are producing smoke or

 

power cord plugs from the outlet, and

 

strange smells may cause fire or elec-

 

then contact your authorized

 

tric shock. In these cases, immedi-

 

TOSHIBA TEC representative for

 

ately turn off the power switches and

 

assistance. Continued use of the

 

disconnect the power cord plugs from

 

 

the outlet. Then, contact your author-

 

machine in that condition may cause

 

 

 

ized TOSHIBA TEC representative for

 

fire or electric shock.

 

 

 

assistance.

 

 

 

 

(i)

Image 6
Contents SL-9000-LSB Series Page TOC Calling Menu by Entering Password Password SecuritySetting Password and Protect Menu Operating ProceduresPage Safety Summary Meanings of Each SymbolPrecautions Introduction Accessories Applicable Model9 0 0 0 3 0 M L S B U S Specification ScaleOption Source Or Part NoAppearance CMT/PL-3 I/F LON I/FDisplay US TypeCA Type QR Type Weight Unit Price AU Type$/kg KEY Layout Programming KeyboardDisplays the next line when setting the ingredient Deletes a selected character when setting commodity namesInserts a space when setting a commodity name Sets a block PLU # using the confirmation label procedureOperation Keyboard and Speed KEY Board Operation Keyboard FunctionEnables calling the other 70 speed keys Sets the quantity of commodity in by Count modeCancels preceding data Selection modeIssue. Optional key by initial setting Issues a test labelAdjusts the zero point No functionProcedure Before Operation Nutrition SettingSpeed KEY SET Installation Procedure Remote DisplayInstallation Procedure Level Adjustment Removal and Replacement of Media Removal and Replacement of Media Outline of Operation Menu selectionProgramming Procedures How to access the Programming MenuHow to Select Menu and Item No Title and Contents of Programming Menu 2nd line TEL How to enter charactersTEC Store Change PLUUnit Price Change MenuGroup Main PLU Data Setting MenuPLU# UPC#Ingredient Message Nutrition Facts Group Daily Value Max digits Contents of daily value Set th e Daily Value TableMemory file is sorted when a memory full error occurs Deleting Nutrition DataMemory file sort PLU Verifying Label GroupAddress Setting Special Information Menu Group Item NoSpeed KEY Setting Setting Department/Vendor NumberPrint Format By pressing KeyLabel Format Number Table 22/38DATE/TIME Setting 11.12 CMT/PL-3Error code during PL-3 operation PL-3 OperationSave Transmission Item List Operable InoperableTransmission Delay Time Table IN-LINE/LOCALLON System ID #Nutrition Free Format Data TransmissionVendor ChangeUPC # BAR Code FormatCurrent format Flag Changed formatC C C C Flag PLU # UPC# PC/D Price WeightH H H H PLU# UPC#See Note Enter the title #Enter the title Title No Format Additional 221Data Error Error message during data transmissionTime OUT Error Transferring Logo DataIdiom Setting Vendor SettingROT Rotation Free Format SettingKey functions MAG Magnification 0 normal11-30 C D B aAvailable format and print items for free format How to access the Read menu Programmed Data Verification ReportsSee the next For Password Security Setting Password and Protect Menu13-2 Calling Menu by Entering Password REGOperating Procedures How to access the REG., M.DOWN, or Rewrap menuWeighing Operation Sample labelFIX Price Operation for US Type only By Count Operation Sample label for US type Sample label for CA and QR type14-5 Print Count Operation Example B When operating in Fix or By Count mode From the platter Labels are being issuedPLU Issuing Labels with NET Weight Statement for US Type only For14-10 TARE/SAVE Function Procedures Remove the commodity Together with the containerRemove the commodity Calling and Printing Grade Lines Calling and Printing Logos Or CSelecting Print Item and Adjusting the LCD Brightness Menu REG, M.DOWN, or Rewrap Mode WEIGH, FIX, or by CountDate Change Batch Print Mode with 30 Items Run Assignment Changing a Unit Price and Calling G.Line/LOGO Stopping or Canceling Label Issue Preset CountFloating Vendor One vendor CommoditiesReceipt will be issued Enter vendor #READ5 RESET6 How to access the Read or Reset menuReset Total OperationHourly Total Report Grand Total ReportPLU Total Report Block Total Ex. UPC Block Total UPC #100100~100199 Vendor Total ReportIndividual Total Ex. Individual PLU Total PLU #100 Zone Total Ex. PLU Zone Total PLU #100~107Error Message Table Programming ModeLabel Issue Mode Read and Reset ModeCMT Operation Mode LON System ModeCleaning the Print Head Troubleshooting Before You Call for Service