Toshiba SL-9000-LSB owner manual Introduction

Page 8

1.INTRODUCTION

1.INTRODUCTION

Thank you for purchasing the TEC SL-9000-LSB Series electronic computing scale. As you will discover, the TEC SL-9000-LSB series has many features and functions designed for user friendliness as well as complete customer satisfaction.

The 7-segment fluorescent display which indicates transaction information such as weights, unit prices, total prices, etc. and the liquid crystal display used to display commodity names and programming messages are provided with the scale. The 140 speed keys realize a higher degree of operability, and the 3 inch/sec. print speed ensures fast and clear printing.

Password security prevents unauthorized access to the PROG., M.DOWN, REWRAP, READ and RESET mode. The latest high speed in-line system, Local Operation Network (LON), allows easy system configuration and greater throughput.

Various options, including a TMCC interface, RS-232C interface, etc., are options available depending on your needs.

We believe that your needs will now be fully satisfied, and you will have total reliability in price calculations. Should you have any questions concerning the scale, please refer to this manual. Be sure to keep this manual for future reference.

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operations of this equipment in a residential area is likely to cause harmful interference in which case the user will be

required to correct the interference at his own expense.

(for USA only)

Changes or modifications not expressly approved by manufacturer for compliance could void the user’s authority to operate the equipment.

“This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.”

“Cet appareil numéique de la classe A respecte toutes les exigences du Rèlement sur le matériel brouilleur du Canada.”

(for CANADA only)

Some procedures described in this manual may be illegal in various state jurisdictions. When there are optional settings to enable various functions or to disable functions. Please ensure that the optional settings for scale operation meet the local requirements of weights and measures. If you are uncertain of specific items, contact the state or county office of weights and measures for clarification.

1-1

Image 8
Contents SL-9000-LSB Series Page TOC Password Security Setting Password and Protect MenuCalling Menu by Entering Password Operating ProceduresPage Safety Summary Meanings of Each SymbolPrecautions Introduction 9 0 0 0 3 0 M L S B U S AccessoriesApplicable Model Specification ScaleOption Source Or Part NoAppearance CMT/PL-3 I/F LON I/FCA Type DisplayUS Type QR Type $/kg Weight Unit PriceAU Type KEY Layout Programming KeyboardDeletes a selected character when setting commodity names Inserts a space when setting a commodity nameDisplays the next line when setting the ingredient Sets a block PLU # using the confirmation label procedureOperation Keyboard and Speed KEY Board Operation Keyboard FunctionSets the quantity of commodity in by Count mode Cancels preceding dataEnables calling the other 70 speed keys Selection modeIssues a test label Adjusts the zero pointIssue. Optional key by initial setting No functionSpeed KEY SET Procedure Before OperationNutrition Setting Installation Procedure Remote DisplayInstallation Procedure Level Adjustment Removal and Replacement of Media Removal and Replacement of Media Outline of Operation Menu selectionHow to Select Menu and Item No Programming ProceduresHow to access the Programming Menu Title and Contents of Programming Menu How to enter characters TEC Store2nd line TEL Change PLUGroup Main Unit Price ChangeMenu PLU Data Setting MenuPLU# UPC#Ingredient Message Nutrition Facts Group Daily Value Max digits Contents of daily value Set th e Daily Value TableMemory file sort Memory file is sorted when a memory full error occursDeleting Nutrition Data PLU Verifying Label GroupAddress Setting Special Information Menu Group Item NoSpeed KEY Setting Setting Department/Vendor NumberPrint Format By pressing KeyLabel Format Number Table 22/38DATE/TIME Setting 11.12 CMT/PL-3Save Error code during PL-3 operationPL-3 Operation Transmission Item List Operable InoperableTransmission Delay Time Table IN-LINE/LOCALLON System ID #Data Transmission VendorNutrition Free Format ChangeBAR Code Format Current format FlagUPC # Changed formatFlag PLU # UPC# PC/D Price Weight H H H HC C C C PLU# UPC#Enter the title # Enter the titleSee Note Title No Format Additional 221Error message during data transmission Time OUT ErrorData Error Transferring Logo DataIdiom Setting Vendor SettingFree Format Setting Key functionsROT Rotation MAG Magnification 0 normal11-30 C D B aAvailable format and print items for free format See the next How to access the Read menuProgrammed Data Verification Reports For Password Security Setting Password and Protect Menu13-2 Calling Menu by Entering Password REGOperating Procedures How to access the REG., M.DOWN, or Rewrap menuWeighing Operation Sample labelFIX Price Operation for US Type only By Count Operation Sample label for US type Sample label for CA and QR type14-5 Print Count Operation Example B When operating in Fix or By Count mode From the platter Labels are being issuedPLU Issuing Labels with NET Weight Statement for US Type only For14-10 Remove the commodity TARE/SAVE Function ProceduresRemove the commodity Together with the container Calling and Printing Grade Lines Calling and Printing Logos Or CSelecting Print Item and Adjusting the LCD Brightness Menu REG, M.DOWN, or Rewrap Mode WEIGH, FIX, or by CountDate Change Batch Print Mode with 30 Items Run Assignment Changing a Unit Price and Calling G.Line/LOGO Stopping or Canceling Label Issue Preset CountFloating Vendor One vendor CommoditiesReceipt will be issued Enter vendor #How to access the Read or Reset menu ResetREAD5 RESET6 Total OperationPLU Total Report Hourly Total ReportGrand Total Report Vendor Total Report Individual Total Ex. Individual PLU Total PLU #100Block Total Ex. UPC Block Total UPC #100100~100199 Zone Total Ex. PLU Zone Total PLU #100~107Error Message Table Programming ModeLabel Issue Mode Read and Reset ModeCMT Operation Mode LON System ModeCleaning the Print Head Troubleshooting Before You Call for Service