Toshiba SL-9000-LSB owner manual Weighing Operation, Sample label

Page 66

14. OPERATING PROCEDURES

14.1 WEIGHING OPERATION

14.1 WEIGHING OPERATION

Menu: REG., M. DOWN, or REWRAP

Mode: WEIGH

The weigh mode is used to weigh a commodity and to issue the label. The label contains data such as a weigh, unit price (price per weight) and total price (calculated as a result of the weighing operation). The following is a basic operation seen at the sales floor of a store or at a back room where different kinds and weights of commodities are repacked. Pressing the VOID key subtracts the last entry from the memory.

Example) When PLU #100 and an unit price of $8.00 are set in the speed key #12.

 

 

 

 

 

 

Enter the PLU #.

1

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Press: PLU

LB

kg

Press the

12

speed key.

 

The unit of measure can be changed for CA model only.

LB kg

Available only when the initial

Remote Display

 

 

 

WEIGHT

UNIT PRICE

TOTAL PRICE

setting # 5-6 is set to 1.

 

 

 

 

 

 

1.000

8.00

8.00

kg scale

 

lb scale

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REG

100 g

1/4

1/2

Liquid Crystal Display

T-BONE STEAK

Place a commodity

 

 

 

 

on the platter.

 

 

 

 

 

(Ex. 1.000 lb.)

 

 

 

 

 

 

 

 

 

 

 

PACKED ON

MANUAL:

PRT

 

: AUTO

 

SELL BY

 

 

 

*

 

 

 

 

 

 

 

 

 

 

 

 

The label is issued.

NET WT.

PRICE lb

 

 

 

 

 

 

TEC STORE

Press when canceling

 

 

(TEL) 0123-45-6789

VOID

 

(Sample label)

the last sales.

 

 

NOTES: 1. Pressing a speed key to which no PLU data has been assigned will result in an error. In this case, press the C key, then press a speed key to which PLU data has been assigned.

2.To change between AUTO and MANUAL, follow the procedure provided in section 14.9.

3.If a unit price exceeding 4 digits is obtained by multiplying by 2 or 4 (when pressing the 1/2 lb key or 1/4 lb key), the unit price will be 0.

4.

100 g key is available only when the scale is a kg scale or operated on kg base.

This key, however, has no function on the AU type.

5.When the 1/2 lb , 1/4 lb or 100 g key is pressed, the unit price will change on the display. The 100 g key, however, has no function on the AU type.

6.When the “compulsory tare” is selected, a tare must be subtracted in a weighing operation, otherwise an error message “TARE REQUIRED” will be displayed when the following operation has been done:

Manual mode: Pressing the PRT/* key

Auto mode: Placing a commodity on the platter.

Floating vendor mode: Pressing the Vendor key.

When a “TARE REQUIRED” is displayed, refer to Section 14.6 to follow the proper weighing procedure.

14-2

Image 66
Contents SL-9000-LSB Series Page TOC Calling Menu by Entering Password Password SecuritySetting Password and Protect Menu Operating ProceduresPage Safety Summary Meanings of Each SymbolPrecautions Introduction Accessories Applicable Model9 0 0 0 3 0 M L S B U S Specification ScaleOption Source Or Part NoAppearance CMT/PL-3 I/F LON I/FDisplay US TypeCA Type QR Type Weight Unit Price AU Type$/kg KEY Layout Programming KeyboardDisplays the next line when setting the ingredient Deletes a selected character when setting commodity namesInserts a space when setting a commodity name Sets a block PLU # using the confirmation label procedureOperation Keyboard and Speed KEY Board Operation Keyboard FunctionEnables calling the other 70 speed keys Sets the quantity of commodity in by Count modeCancels preceding data Selection modeIssue. Optional key by initial setting Issues a test labelAdjusts the zero point No functionProcedure Before Operation Nutrition SettingSpeed KEY SET Installation Procedure Remote DisplayInstallation Procedure Level Adjustment Removal and Replacement of Media Removal and Replacement of Media Outline of Operation Menu selectionProgramming Procedures How to access the Programming MenuHow to Select Menu and Item No Title and Contents of Programming Menu 2nd line TEL How to enter charactersTEC Store Change PLUUnit Price Change MenuGroup Main PLU Data Setting MenuPLU# UPC#Ingredient Message Nutrition Facts Group Daily Value Max digits Contents of daily value Set th e Daily Value TableMemory file is sorted when a memory full error occurs Deleting Nutrition DataMemory file sort PLU Verifying Label GroupAddress Setting Special Information Menu Group Item NoSpeed KEY Setting Setting Department/Vendor NumberPrint Format By pressing KeyLabel Format Number Table 22/38DATE/TIME Setting 11.12 CMT/PL-3Error code during PL-3 operation PL-3 OperationSave Transmission Item List Operable InoperableTransmission Delay Time Table IN-LINE/LOCALLON System ID #Nutrition Free Format Data TransmissionVendor ChangeUPC # BAR Code FormatCurrent format Flag Changed formatC C C C Flag PLU # UPC# PC/D Price WeightH H H H PLU# UPC#See Note Enter the title #Enter the title Title No Format Additional 221Data Error Error message during data transmissionTime OUT Error Transferring Logo DataIdiom Setting Vendor SettingROT Rotation Free Format SettingKey functions MAG Magnification 0 normal11-30 C D B aAvailable format and print items for free format How to access the Read menu Programmed Data Verification ReportsSee the next For Password Security Setting Password and Protect Menu13-2 Calling Menu by Entering Password REGOperating Procedures How to access the REG., M.DOWN, or Rewrap menuWeighing Operation Sample labelFIX Price Operation for US Type only By Count Operation Sample label for US type Sample label for CA and QR type14-5 Print Count Operation Example B When operating in Fix or By Count mode From the platter Labels are being issuedPLU Issuing Labels with NET Weight Statement for US Type only For14-10 TARE/SAVE Function Procedures Remove the commodity Together with the containerRemove the commodity Calling and Printing Grade Lines Calling and Printing Logos Or CSelecting Print Item and Adjusting the LCD Brightness Menu REG, M.DOWN, or Rewrap Mode WEIGH, FIX, or by CountDate Change Batch Print Mode with 30 Items Run Assignment Changing a Unit Price and Calling G.Line/LOGO Stopping or Canceling Label Issue Preset CountFloating Vendor One vendor CommoditiesReceipt will be issued Enter vendor #READ5 RESET6 How to access the Read or Reset menuReset Total OperationHourly Total Report Grand Total ReportPLU Total Report Block Total Ex. UPC Block Total UPC #100100~100199 Vendor Total ReportIndividual Total Ex. Individual PLU Total PLU #100 Zone Total Ex. PLU Zone Total PLU #100~107Error Message Table Programming ModeLabel Issue Mode Read and Reset ModeCMT Operation Mode LON System ModeCleaning the Print Head Troubleshooting Before You Call for Service