Digi DC-190 Spec Min Max, Connector, select, Selecting 1 can damage, Components

Page 17

SPEC

Default

 

 

Bit 3

 

 

Bit 2

 

 

 

Bit 1

 

 

Bit 0

 

 

 

 

 

 

 

 

 

 

 

27

0100

Comma Display

Keypad Entry of Tare

 

Tare Range

 

 

 

 

 

 

0: No

 

 

0: No

 

 

 

00: 100% FS

 

01:

50% FS

 

 

1: Yes

 

 

1: Yes

 

 

 

10: 5% FS

 

11: Not used

 

 

 

 

 

 

 

28

0000

Auto Tare Clear when

Automatic Unit Weight Clear Condition

 

Automatic Unit Weight

 

 

Rezeroed

 

00: Over net 5d and gross 21d, weight stable

Clear

 

 

 

 

 

 

 

 

 

 

 

 

 

0:

No

 

 

01: Greater than or equal to net 1d, weight stable

0: No

 

 

 

 

1:

Yes (REZERO

10: Greater than or equal to net 1d, quantity > 0,

1: Yes

 

 

 

 

 

clears tare value)

weight stable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

29

0000

Digital Tare Rounding

Tare Value Exchange

 

Tare Addition

 

Tare Subtraction

 

 

0: Tare exactly

 

with TARE key

 

 

0:Yes (new tare weight

0: Yes (new tare weight

 

 

 

 

 

 

 

 

 

1: Round to nearest

0: Yes (allow tare

 

added to existing tare)

subtracted from

 

 

 

increment

 

addition/subtraction)

1:No

 

 

existing tare)

 

 

 

 

 

 

1: No

 

 

 

 

 

 

1: No

 

 

 

 

 

 

 

 

 

 

 

 

30

none

Load Cell Sensitivity Selection (mV/V)—PORT 1, Scale 1

 

 

 

 

 

 

 

Load cell sensitivity is automatically set at calibration. Manual adjustments can be made to reduce noise.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Spec

Min

Max

Spec

Min

Max

 

Spec

Min

Max

Spec

Min

Max

 

 

0000:

3.46

4.00

0100:

1.95

2.25

 

1000:

1.09

1.27

1100:

0.61

0.71

 

 

0001:

3.00

3.46

0101:

1.69

1.95

 

1001:

0.95

1.09

1101:

0.53

0.91

 

 

0010:

2.59

3.00

0110:

1.46

1.69

 

1010:

0.82

0.95

1110:

0.46

0.53

 

 

0011:

2.25

2.59

0111:

1.27

1.46

 

1011:

0.71

0.82

 

 

 

1111:

0.40

0.46

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

31

none

Load Cell Sensitivity Selection (mV/V)—PORT 1, Scale 2

 

 

 

 

 

 

 

Load cell sensitivity is automatically set at calibration. Manual adjustments can be made to reduce noise.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Spec

Min

Max

Spec

Min

Max

 

Spec

Min

Max

Spec

Min

Max

 

 

0000:

3.46

4.00

0100:

1.95

2.25

 

1000:

1.09

1.27

1100:

0.61

0.71

 

 

0001:

3.00

3.46

0101:

1.69

1.95

 

1001:

0.95

1.09

1101:

0.53

0.91

 

 

0010:

2.59

3.00

0110:

1.46

1.69

 

1010:

0.82

0.95

1110:

0.46

0.53

 

 

0011:

2.25

2.59

0111:

1.27

1.46

 

1011:

0.71

0.82

 

 

 

1111:

0.40

0.46

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

32

1010

Calibration Mode

Low Battery

 

 

Auto Exit from Part

Scale Connected to

 

 

Protected by Span

Annunciator Enabled

 

Accumulation and

PORT 2

 

 

 

Switch

 

 

0: Yes

 

 

 

Reduction Mode

0: No

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0: Yes (span switch

1: No

 

 

 

0:No (must press

1: Yes

 

 

 

 

 

must be pressed

 

 

 

 

CLEAR to perform

CAUTION: If you are not

 

 

 

before calibration)

 

 

 

 

another accumulation)

 

 

 

 

 

 

 

connecting a scale to this

 

 

1: No

 

 

 

 

 

 

1:Yes (exits to counting

 

 

 

 

 

 

 

 

connector, select 0.

 

 

 

 

 

 

 

 

 

 

mode after three

 

 

 

 

 

 

 

 

 

 

Selecting 1 can damage

 

 

 

 

 

 

 

 

 

 

seconds)

 

 

 

 

 

 

 

 

 

 

 

 

the console’s electronic

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

components.

 

 

 

 

 

 

 

 

 

33

0___

Over Weight Mask at:

Weight Decimal Point Position (PORT 2, Scale 2 or 3)

 

 

 

 

0: +1d

 

 

MUST BE SET PRIOR TO CALIBRATION!

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1: +9d

 

 

000: 00000

 

011: 00.000

 

 

 

 

 

 

 

 

 

 

 

001: 0000.0

 

100: 0.0000

 

 

 

 

 

 

 

 

 

 

 

010: 000.00

 

101: 0.00000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

34

0000

Not used

 

A/D Output (PORT 1,

 

A/D Filtering (PORT 1, Scale 1)

 

 

 

 

 

 

 

 

Scale 1)

 

 

00: Normal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0: For std/normal load

01: Protect from small vibration/fast change in

 

 

 

 

 

 

cell

(≤ 18 mV)

 

display

 

 

 

 

 

 

 

 

 

 

1: For abnormal load

 

10: Protect from medium vibration

 

 

 

 

 

 

 

 

cell with too large

 

11: Protect from large vibration, slow change in

 

 

 

 

 

 

offset (> 18mV)

 

display

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 4-2. DC-190 142 Settings (Continued)

Image 17
Contents DC-190 Introduction Repacking DC-190 Scale Capacities and ResolutionsUnpacking and Inspection Other S-Series Remote Platforms Scale no DC-190 ConsoleUW/1000 Pcs 2 DC-190 Keypad Locking and Unlocking InstallationSetting Up Location of AC Power Cord Receptacle Load Cell Cable Powering Up the DC-190Location of Top Cover Screws Setting Time and DatePole Mounting Instructions Installing Cable Strain ReliefSpec Scale SetupScale Configurations Spec SPEC17 APW Customer Specification 141 SettingsSwitching if Spec 2, bit 1 is set DIN-8 Force Balance 010 Weight and Measurement Specifications 142 Settings Spec Connector, selectSpec Min Max Selecting 1 can damageMax Spec Min Load Cell Sensitivity Selection mV/V-PORT 2, Scale 2 orNot used set to RS-232 Specifications 143 SettingsScale Operations Entering Tare WeightsToggle Between Scales Toggling Between Net and Gross WeightEntering Unit Weights Unit Weight Operation by Key Entry Other Operations Item Code Storage Scale ProgrammingItem Code Maintenance Using Item Code in Normal Mode Re-Computing Item Code Unit Weight Procedure Pin DIN Female Connector PinoutsDC-190 Messages Clearing Locked-Up Scale 888888 Error 10.11 DC-190 Ultra Count Specifications DC-190 Ultra Count Limited Warranty