Digi DC-190 installation manual Using Item Code in Normal Mode

Page 26

NOTE: When you hear the beep, the display shows the last item code in memory. Press the key to review the item codes in reverse order.

4.Press the MODE key to return to Step 1.

5.Press the MODE key again to return to weighing mode.

Delete Item Memory

The following procedure describes the steps used to delete all information stored within each item code (unit weight, tare weight, part number, quantity, part, setpoints, and lot number) or any specific information stored within each item code. It also explains the keystrokes required for resetting the sequence number, or deleting all setpoints, global to the scale, but not tied to a specific item code.

1.Press the MODE key. The WEIGHT display will show ProG and the QUANTITY display shows C XX.

2.While pressing the REZERO key, enter the sequence as shown in Table 7-2 to delete the specified information. The table shows the prompting that will take place on the weight and quantity displays to ensure that the proper keystrokes have been performed.

NOTE: If an error was made entering data and the display is prompting you to clear information that is not to be cleared, press the MODE key and return to Step 1.

3.Press the CLEAR key to delete the information.

4.Press MODE to exit programming mode.

Delete Item Memory

Sequence

WEIGHT Display

QUANTITY Display

 

 

 

 

Delete all memories

••0

ALL

CLEAr

 

 

 

 

All item quantity in stock

••1

InVEnt

CLEAr

 

 

 

 

All item unit weights

••2

UnIt u

CLEAr

 

 

 

 

All item tare weights

••3

TArE

CLEAr

 

 

 

 

All item part numbers

••4

P-no

CLEAr

 

 

 

 

All item setpoints

••5

P-SP

CLEAr

 

 

 

 

All item names

••6

P-nAmE

CLEAr

 

 

 

 

Reset SEQ numbers

••7*

SEQ no

CLEAr

 

 

 

 

Delete all setpoints (global)

••+

SEt P

CLEAr

 

 

 

 

*Use for BCP-30 printer

 

 

 

 

 

 

 

Table 7-2. Deleting Item Codes in Memory

7.3Using Item Code in Normal Mode

The following paragraphs describe the procedure to recall item codes, recompute item code unit weights, set new item codes, and inventory operations related to the item code quantity. All storage operations are done while the scale is in the normal mode.

Recalling Numeric Item Codes using Item Code Number

1.Enter item code number using numeric keypad.

2.Press the CODE key. The scale will recall all information stored with the item code and automatically return to the normal mode.

Recalling Alphanumeric Item Codes using Teraoka Code

1.Press the . (decimal) key. The WEIGHT display prompts t-C 01, the QUANTITY display shows CodE, and the UNIT-WEIGHTdisplay prompts 00-.

2.Enter the values equivalent to the digits to be entered using the Teraoka Code. For example, to recall Item Code 123, enter: [31], [32], [33], [01], [02], [03] = 123ABC.

3.Press the CODE key. The scale will recall all information stored with the item code and automatically return to the normal mode.

Image 26
Contents DC-190 Introduction Repacking DC-190 Scale Capacities and ResolutionsUnpacking and Inspection Other S-Series Remote Platforms Scale no DC-190 ConsoleUW/1000 Pcs 2 DC-190 Keypad Locking and Unlocking InstallationSetting Up Powering Up the DC-190 Location of AC Power Cord Receptacle Load Cell CableSetting Time and Date Location of Top Cover ScrewsInstalling Cable Strain Relief Pole Mounting InstructionsSpec Scale SetupScale Configurations Spec SPEC17 APW Customer Specification 141 SettingsSwitching if Spec 2, bit 1 is set DIN-8 Force Balance 010 Weight and Measurement Specifications 142 Settings Spec Min Max Connector, selectSpec Selecting 1 can damageLoad Cell Sensitivity Selection mV/V-PORT 2, Scale 2 or Max Spec MinRS-232 Specifications 143 Settings Not used set toEntering Tare Weights Scale OperationsToggle Between Scales Toggling Between Net and Gross WeightEntering Unit Weights Unit Weight Operation by Key Entry Other Operations Scale Programming Item Code StorageItem Code Maintenance Using Item Code in Normal Mode Re-Computing Item Code Unit Weight Procedure Connector Pinouts Pin DIN FemaleDC-190 Messages Clearing Locked-Up Scale 888888 Error 10.11 DC-190 Ultra Count Specifications DC-190 Ultra Count Limited Warranty