Digi Unpacking and Inspection, Repacking, DC-190 Scale Capacities and Resolutions

Page 3

1.1Unpacking and Inspection

Immediately after unpacking, visually inspect the DC-190 Ultra Count to ensure all components are included and undamaged. If any items were damaged in shipment, notify Rice Lake Weighing Systems and the shipper immediately.

Ensure all accessories are removed from the cartons, then replace all packing materials in the cartons and store in a safe place. Use the original cartons whenever shipment of the scale is required.

1.2Repacking

If the DC-190 counting scale must be returned for modification, calibration, or repair, it must be properly packed with sufficient cushioning materials and the load cell must be locked to prevent damage to the load cell (see Section 2.1 on page 6).

Whenever possible, use the original carton when shipping the DC-190. Damage caused by improper packaging is not be covered by warranty.

1.3DC-190 Scale Capacities and Resolutions

Counting scales specify two types of resolution:

Weight (or external) resolution

Counting (or internal) resolution

Weight resolution is displayed in increments of the full scale capacity which is divided into weight increments. For example, a 5-lb scale divided into 10,000 display divisions would display weight with 0.0005 lb divisions (10,000 divisions x 0.0005 lb = 5.0 lb).

Counting resolution is based on the internal resolution of the scale. The weight and counting resolutions for the DC-190 single- and dual-platform capacities are listed below.

Tables 1-1 through 1-3 list the scale capacities and resolutions for all models of the DC-190 counting scales.

Model

 

 

Capacity (lb)

 

Weighing Resolution (lb)

Internal Resolution (lb)

Platform Dimensions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S-XL-1.0

 

 

1.0

 

 

 

0.0001

 

 

0.000001

 

 

6” x 8”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S-XL-2.5

 

 

2.5

 

 

 

0.0002

 

 

0.0000025

 

 

7” x 10”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S-XL-5.0

 

 

5.0

 

 

 

0.0005

 

 

0.000005

 

11” x 16”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S-XL-10

 

 

10.0

 

 

 

0.001

 

 

0.00001

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S-XL-25

 

 

25.0

 

 

 

0.002

 

 

0.000025

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S-XL-50

 

 

50.0

 

 

 

0.005

 

 

0.00005

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S-XL-100

 

 

100.0

 

 

 

0.01

 

 

0.0001

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 1-1. DC-190 S-XL Scale Capacities

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Capacity (lb)

 

Weighing Resolution (lb)

Internal Resolution (lb)

 

Platform Dimensions

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

Scale 1

Scale 2

 

Scale 1

Scale 2

Scale 1

 

Scale 2

 

Sample

 

Bulk

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S-XD-1/10

1.0

10

 

0.0001

0.001

0.000001

 

0.00001

 

4” x 6”

 

9” x 12”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S-XD-1/25

 

 

25

 

 

 

0.002

 

 

 

0.000025

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S-XD-1/50

 

 

50

 

 

 

0.005

 

 

 

0.00005

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S-XD-2.5/25

2.5

25

 

0.0002

0.002

0.0000025

 

0.000025

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S-XD-2.5/50

 

 

50

 

 

 

0.005

 

 

 

0.00005

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 1-2. DC-190 S-XD Scale Capacities

Image 3
Contents DC-190 Introduction DC-190 Scale Capacities and Resolutions Unpacking and InspectionRepacking Other S-Series Remote Platforms DC-190 Console UW/1000 PcsScale no 2 DC-190 Keypad Installation Setting UpLocking and Unlocking Location of AC Power Cord Receptacle Load Cell Cable Powering Up the DC-190Location of Top Cover Screws Setting Time and DatePole Mounting Instructions Installing Cable Strain ReliefScale Setup Scale ConfigurationsSpec Spec SPEC17 Customer Specification 141 Settings Switching if Spec 2, bit 1 is setAPW DIN-8 Force Balance 010 Weight and Measurement Specifications 142 Settings Selecting 1 can damage Connector, selectSpec Spec Min MaxMax Spec Min Load Cell Sensitivity Selection mV/V-PORT 2, Scale 2 orNot used set to RS-232 Specifications 143 SettingsScale Operations Entering Tare WeightsToggling Between Net and Gross Weight Entering Unit WeightsToggle Between Scales Unit Weight Operation by Key Entry Other Operations Item Code Storage Scale ProgrammingItem Code Maintenance Using Item Code in Normal Mode Re-Computing Item Code Unit Weight Procedure Pin DIN Female Connector PinoutsDC-190 Messages Clearing Locked-Up Scale 888888 Error 10.11 DC-190 Ultra Count Specifications DC-190 Ultra Count Limited Warranty