Digi DC-190 Customer Specification 141 Settings, Apw, Switching if Spec 2, bit 1 is set

Page 13

4.2Customer Specification (141 Settings)

To configure customer specifications, press and hold the REZERO key and enter 141 using the numeric keypad. SPC00 appears in the WEIGHT display and configuration of four bits (for SPEC 0) appears in QUANTITY display. Follow the procedure described in Section 4.1 on page 17 to update the SPEC settings for the 141 access code.

SPEC

Default

 

 

Bit 3

 

 

 

Bit 2

 

 

Bit 1

 

Bit 0

 

 

 

 

 

 

 

0

0000

Transfer Tare Weight

Tare Accumulation

 

Terminator (RS-232 only)

Piece Weight Selection

 

 

0: No (hold tare)

 

0:

No (overwrite tare)

0: Carriage return

0: Unit wt per 1000

 

 

1: Yes (transfer tare)

1: Yes (add to existing

1: Carriage return +

1: Average piece wt

 

 

 

 

 

 

 

tare)

 

 

 

linefeed

 

(APW)

 

 

 

 

 

 

1

0000

Power Auto Off Function: Function used to preserve and extend battery life. All four bits are used to

 

 

specify the number of minutes (binary) before the scale enters autopower off mode.Examples below show

 

 

the binary code, time delay, and description. Settings can range from 0–15 minutes in 1-minute

 

 

increments.

 

 

 

 

 

 

 

 

 

 

 

Binary Code

 

 

 

 

 

 

 

 

 

 

 

8421

Time (min)

Description

 

 

 

 

 

 

 

 

 

0000

0

Autopower off is disabled.

 

 

 

 

 

 

 

0111

7

If net weight is zero and no motion for 7 minutes, scale goes into autopower off mode.

 

 

1111

15

If net weight is zero and no motion for 15 minutes, scale goes into autopower off mode.

 

 

NOTE: Powering down means that accumulated value is lost and not retained upon power up. However,

 

 

all total inventory values stored with item codes are retained.

 

 

 

 

 

 

 

 

 

 

 

2

1000

Scale Specification

 

 

 

 

Kg/Lb Lamp Enable

Inventory Display by Net/

 

 

00: Gram (no units switching)

01: Kg

 

0: Yes

Gross Key

 

 

 

 

 

 

 

10: Lb

 

 

11: Not used

1: No

0:

No (Net/Gross toggle)

 

 

NOTE: Values 01 and 10 allow Lb/Kg units

 

 

 

1:

Yes (INVENT key

 

 

 

 

 

shows inventory quantity)

 

 

 

 

switching if SPEC 2, bit 1 is set 0.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

0000

RS-232 Port Commands (D-sub)

 

 

Print Commands (8-pin DIN)

 

 

 

00: Standard RS-232 (PC, force balance)

 

00: BCP-30 (barcode printer, force balance)

 

 

01:

 

TM-U295 ticket printer

 

 

 

01:

TM-U295 ticket printer

 

 

 

10: TM-U200 (with or without cutter)

 

10: TM-U200 (with or without cutter)

 

 

11: TM-U200 (with feed for tear-off)

 

11:

TM-U200 (with feed for tear-off)

 

 

 

 

 

 

 

4

1001

Set New Item Code

Insufficient Sample Level

 

 

Negative Counting

 

 

During Normal Mode

00:

0.1%

 

 

 

0:

No

 

 

 

 

 

 

 

 

 

 

 

0:

Yes

 

01:

0.2%

 

 

 

1:

Yes

 

 

1:

No

 

10:

0.0%

 

 

 

 

 

 

 

 

 

 

 

 

 

5

1011

Sampling Time for Unit

Unit Weight

 

Date Order

 

 

 

 

Weight Calculations

Auto-Recomputing

 

00:

Year, Month, Day

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0:

10 times

 

0:

Press

PIECES

key

01:

Day, Month, Year

 

 

 

 

1:

5 times

 

after adding number of

11:

Month, Day, Year

 

 

 

 

 

 

 

 

pieces

 

 

 

 

 

 

 

 

 

 

 

 

1:

Scale

automatically

 

 

 

 

 

 

 

 

 

 

recomputes

after

 

 

 

 

 

 

 

 

 

 

adding

number

of

 

 

 

 

 

 

 

 

 

 

pieces without pressing

 

 

 

 

 

 

 

 

 

 

PIECES key

 

 

 

 

 

 

 

 

 

 

 

6

1001

Display Accuracy of

Clear Key Operation

RS-232 Continue

Auto Shift to Next

 

 

Unit Weight

 

0:

Clear all data

 

Sending Rate to PC

Character After Two Digits

 

 

 

 

 

 

 

 

 

of Teraoka Code Entry

 

 

0:

No

 

1:

Clear last character

0: High

 

 

 

 

 

 

 

1:

Yes

 

 

 

 

 

1: Low

0: No (requires + key)

 

 

 

 

 

 

 

 

 

 

 

 

1:

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 4-1. DC-190 141 Settings

Image 13
Contents DC-190 Introduction Unpacking and Inspection DC-190 Scale Capacities and ResolutionsRepacking Other S-Series Remote Platforms UW/1000 Pcs DC-190 ConsoleScale no 2 DC-190 Keypad Setting Up InstallationLocking and Unlocking Location of AC Power Cord Receptacle Load Cell Cable Powering Up the DC-190Location of Top Cover Screws Setting Time and DatePole Mounting Instructions Installing Cable Strain ReliefScale Configurations Scale SetupSpec Spec SPEC17 Switching if Spec 2, bit 1 is set Customer Specification 141 SettingsAPW DIN-8 Force Balance 010 Weight and Measurement Specifications 142 Settings Spec Connector, selectSpec Min Max Selecting 1 can damageMax Spec Min Load Cell Sensitivity Selection mV/V-PORT 2, Scale 2 orNot used set to RS-232 Specifications 143 SettingsScale Operations Entering Tare WeightsEntering Unit Weights Toggling Between Net and Gross WeightToggle Between Scales Unit Weight Operation by Key Entry Other Operations Item Code Storage Scale ProgrammingItem Code Maintenance Using Item Code in Normal Mode Re-Computing Item Code Unit Weight Procedure Pin DIN Female Connector PinoutsDC-190 Messages Clearing Locked-Up Scale 888888 Error 10.11 DC-190 Ultra Count Specifications DC-190 Ultra Count Limited Warranty