Digi DC-190 installation manual RS-232 Specifications 143 Settings, Not used set to

Page 19

4.4RS-232 Specifications (143 Settings)

To configure RS-232 specifications, press and hold the REZERO key and enter 143 using the numeric keypad. SPC40 appears in WEIGHT display and configuration of four bits (for SPEC 40) appears in QUANTITY display. Follow the procedure described in Section 4.1 on page 17 to update the SPEC settings for the 143 access code.

SPECs 40–42 and SPEC 43, bits 0–2, represent the selectable RS-232 output fields.

SPECs 46–59 are not used. All bits for these SPECs must be set to 0.

SPEC

Bit 3

Bit 2

Bit 1

Bit 0

 

 

 

 

 

40

Lot Number

Memo (Part Name)

Alternative Part Number

ID Code

 

0: Yes

0: Yes

0: Yes

0: Yes

 

1: No

1: No

1: No

1: No

 

 

 

 

 

41

Net Weight

Gross Weight

Setpoint

Inventory

 

0: Yes

0: Yes

0: Yes

0: Yes

 

1: No

1: No

1: No

1: No

 

 

 

 

 

42

Date and Time

Quantity & Total Quantity

Unit Weight

Tare Weight

 

0: Yes

0: Yes

0: Yes

0: Yes

 

1: No

1: No

1: No

1: No

 

 

 

 

 

43

Autoprint within Setpoints

Non-stable Ouput

Status Output

Scale Number

 

0: No

0: No

0: Yes

0: Yes

 

1: Yes

1: Yes (allow serial output

1: No

1: No

 

 

with scale in motion)

 

 

 

 

 

 

 

44

Clear Operator Name

Company Name

Manual Print with Setpoints

Autoprint Overrange

 

Each Use (BCP-300)

(BCP-300)

0: Yes

Setpoint

 

 

 

 

 

0: No (operator name held

0: Default only

1: No

0: No

 

in register for multiple

1: Input with bar board

 

1: Yes

 

inputs)

 

 

 

 

1: Yes

 

 

 

 

 

 

 

 

45

Not used

Not used

Print with Zero Quantity

Batch Print Once

 

 

 

0: No

0: No

 

 

 

1: Yes

 

 

 

1: Yes

 

 

 

 

 

 

 

 

 

46–59

Not used: set to 0

Not used: set to 0

Not used: set to 0

Not used: set to 0

 

 

 

 

 

Table 4-3. DC-190 143 Settings

Image 19
Contents DC-190 Introduction Unpacking and Inspection DC-190 Scale Capacities and ResolutionsRepacking Other S-Series Remote Platforms UW/1000 Pcs DC-190 ConsoleScale no 2 DC-190 Keypad Setting Up InstallationLocking and Unlocking Location of AC Power Cord Receptacle Load Cell Cable Powering Up the DC-190Location of Top Cover Screws Setting Time and DatePole Mounting Instructions Installing Cable Strain ReliefScale Configurations Scale SetupSpec Spec SPEC17 Switching if Spec 2, bit 1 is set Customer Specification 141 SettingsAPW DIN-8 Force Balance 010 Weight and Measurement Specifications 142 Settings Selecting 1 can damage Connector, selectSpec Spec Min MaxMax Spec Min Load Cell Sensitivity Selection mV/V-PORT 2, Scale 2 orNot used set to RS-232 Specifications 143 SettingsScale Operations Entering Tare WeightsEntering Unit Weights Toggling Between Net and Gross WeightToggle Between Scales Unit Weight Operation by Key Entry Other Operations Item Code Storage Scale ProgrammingItem Code Maintenance Using Item Code in Normal Mode Re-Computing Item Code Unit Weight Procedure Pin DIN Female Connector PinoutsDC-190 Messages Clearing Locked-Up Scale 888888 Error 10.11 DC-190 Ultra Count Specifications DC-190 Ultra Count Limited Warranty