Digi DC-190 installation manual Connector Pinouts, Pin DIN Female

Page 29

10.3 Connector Pinouts

The DC-190 provides CTS/RTS hardware handshaking lines on both the 8-pin DIN and 9-pin D-Sub connectors. For devices that do not require hardware handshaking, short the CTS/RTS lines on the scale side of the cable.

8-Pin DIN Female

Figure 10-1. 8-Pin DIN Female

Pin

Scanner DIN

Force Balance DIN

Number

Connector

Connector

 

 

 

1

DTR

DTR

 

 

 

2

SIGNAL GND

SIGNAL GND

 

 

 

3

DSR

DSR

 

 

 

4

RXD

RXD

 

 

 

5

TXD

TXD

 

 

 

6

CTS

CTS

 

 

 

7

RTS

RTS

 

 

 

8

Vcc (5 V)

N/C

 

 

 

Table 10-6. Eight-Pin DIN Connector Pin Assignments

14-Pin Amphenol

Figure 10-2. 14-Pin Amphenol Female

 

Remote Platform Connector

Pin Number

Description

 

 

1

Not used

 

 

2

 

 

 

3

+EXCITATION

 

 

4

–EXCITATION

 

 

5

SHIELD*

 

 

6

+SIGNAL

 

 

7

–SIGNAL

 

 

8

GROUND*

 

 

9 through 14

Not used

 

 

* When using the Y cable, use pin 5 instead of pin 8 as ground.

9-Pin D-Sub Female

Figure 10-3. 9-Pin D-Sub Female

Pin Number

Description

 

 

1

DCD

 

 

2

RXD

 

 

3

TXD

 

 

4

DTR

 

 

5

SIGNAL GND

 

 

6

DSR

 

 

7

RTS

 

 

8

CTS

 

 

9

RI

 

 

Table 10-8. 9-Pin D-Sub Connector Pin Assignments

Setpoint Mini DIN

Figure 10-4. Setpoint Mini DIN Female

Pin Number

Setpoint Configuration

 

 

1

SP-1

 

 

2

SP-2

 

 

3

SP-3

 

 

4

SP-4

 

 

5

SP-5

 

 

6

SP-6

 

 

7

+5V

 

 

8

GND

 

 

Table 10-9. Setpoint Configuration Pin Assignments

Table 10-7. Remote Platform Pin Assignments

Image 29
Contents DC-190 Introduction Repacking DC-190 Scale Capacities and ResolutionsUnpacking and Inspection Other S-Series Remote Platforms Scale no DC-190 ConsoleUW/1000 Pcs 2 DC-190 Keypad Locking and Unlocking InstallationSetting Up Location of AC Power Cord Receptacle Load Cell Cable Powering Up the DC-190Location of Top Cover Screws Setting Time and DatePole Mounting Instructions Installing Cable Strain ReliefSpec Scale SetupScale Configurations Spec SPEC17 APW Customer Specification 141 SettingsSwitching if Spec 2, bit 1 is set DIN-8 Force Balance 010 Weight and Measurement Specifications 142 Settings Spec Connector, selectSpec Min Max Selecting 1 can damageMax Spec Min Load Cell Sensitivity Selection mV/V-PORT 2, Scale 2 orNot used set to RS-232 Specifications 143 SettingsScale Operations Entering Tare WeightsToggle Between Scales Toggling Between Net and Gross WeightEntering Unit Weights Unit Weight Operation by Key Entry Other Operations Item Code Storage Scale ProgrammingItem Code Maintenance Using Item Code in Normal Mode Re-Computing Item Code Unit Weight Procedure Pin DIN Female Connector PinoutsDC-190 Messages Clearing Locked-Up Scale 888888 Error 10.11 DC-190 Ultra Count Specifications DC-190 Ultra Count Limited Warranty