Digi DC-190 installation manual Scale Operations, Entering Tare Weights

Page 20

6.0Scale Operations

The following sections contain detailed operator instructions for the DC-190 counting scale. Included are instructions to enter tare weights, toggle between net and gross weight, enter unit weights, perform inventory accumulation and reduction, and toggle between scales. All operator functions are conducted with the scale in the weighing or normal mode. See Section 7.0 on page 30 for information about scale programming.

Counting scale accuracy is primarily determined by the following factors:

Sample size (number of pieces)

Total sample size as a percentage of full scale capacity

Piece-to-piece weight variation

As a general rule when determining sample size of fairly uniform pieces, the larger the sample size the greater the total sample weight, therefore, the better the counting accuracy. Selecting the smallest capacity scale that can obtain the highest counting resolution should be considered, but should not sacrifice the capacity required for the heaviest container of parts. For this specific application, a dual-platform scale may be the best selection.

There is a direct relationship between piece-to-piece weight variation (non-uniformity) and counting accuracy. Therefore, elimination of the piece-to-piece weight variations can be accomplished by:

1.Isolating the sample used to calculate the unit weight and use the same sample to re-check the scale.

2.Recalculating the unit weight from lot-to-lot of parts. Parts manufactured on one machine may vary slightly from another machine relative to weight.

3.Tightening the manufacturing tolerances on the parts reduces piece weight variations and increases count accuracy.

6.1Entering Tare Weights

Tare weights can be entered in the scale by one of two methods: one-touch tare or digital tare.

NOTES:

SPEC 27, bit 2 (Digital Tare Setting) must be a 1 to allow digital tare.

SPEC 27, bits 0 and 1 (Tare Range) must be set to the appropriate tare range value. Default is 00, 100 percent of full scale.

One-Touch Tare, Tare Weight Unknown

1.If the tare weight value is not known, place the container, box, or item to be tared on the scale and press TARE. The WEIGHT display should now show 0 and the NET annunciator should illuminate.

2.Remove the container, box, or item from the scale. The WEIGHT display should show a negative weight value (weight of the tared container, box, or item).

3.Press TARE to reset tare to zero.

Digital Tare, Tare Weight Known

1.If the tare weight value is known, use the numeric keypad to key in the value and then press TARE.

2.Press TARE to reset tare to zero.

NOTE: For digital tare entry, the decimal must be in the appropriate place as it would be displayed in the WEIGHT display. For example, .250 would be entered as 0.250, not .250. The WEIGHT display shows weight entered with a negative sign indicating that it is a tare weight.

Image 20
Contents DC-190 Introduction Repacking DC-190 Scale Capacities and ResolutionsUnpacking and Inspection Other S-Series Remote Platforms Scale no DC-190 ConsoleUW/1000 Pcs 2 DC-190 Keypad Locking and Unlocking InstallationSetting Up Powering Up the DC-190 Location of AC Power Cord Receptacle Load Cell CableSetting Time and Date Location of Top Cover ScrewsInstalling Cable Strain Relief Pole Mounting InstructionsSpec Scale SetupScale Configurations Spec SPEC17 APW Customer Specification 141 SettingsSwitching if Spec 2, bit 1 is set DIN-8 Force Balance 010 Weight and Measurement Specifications 142 Settings Connector, select Spec Spec Min Max Selecting 1 can damageLoad Cell Sensitivity Selection mV/V-PORT 2, Scale 2 or Max Spec MinRS-232 Specifications 143 Settings Not used set toEntering Tare Weights Scale OperationsToggle Between Scales Toggling Between Net and Gross WeightEntering Unit Weights Unit Weight Operation by Key Entry Other Operations Scale Programming Item Code StorageItem Code Maintenance Using Item Code in Normal Mode Re-Computing Item Code Unit Weight Procedure Connector Pinouts Pin DIN FemaleDC-190 Messages Clearing Locked-Up Scale 888888 Error 10.11 DC-190 Ultra Count Specifications DC-190 Ultra Count Limited Warranty