Digi installation manual 10.11 DC-190 Ultra Count Specifications

Page 32

10.11 DC-190 Ultra Count Specifications

Power

Power source

100–120VAC or 220–240 VAC at

 

50/60 Hz

Power consumption

20 W

Analog Specifications

Input sensitivity

0.40–4.00 mV/V

Zero adjustment range

100% FS

A/D conversion rate

10/sec

Load cell excitiation

12V DC

Load cells per scale

4 x 350Ω

Load cell connectors

2 x 14-pin Amphenol

Scale channels

Up to four: three analog (load cell)

 

scales, plus one force balance

Weightdisplay resolution

1/10000, 1/5000, 1/2500

Counting resolution

1/1000000

Digital Specifications

Weight display

5 digits

Unit weight display

5 digits

Quantity display

7 digits

Item memory

200 items, expandable with IMS

 

software

Serial Communications and Setpoint Connectors

SCANNER port

8-pin DIN, RS-232C

FORCE BALANCE port

8-pin DIN, RS-232C

232C/PRINTER port

9-pin D-Sub, RS-232C

Setpoint output

8-pin mini-DIN, 24V open collector

Environmental

Operating temperature

14°F to 104°F (–10°C ° to 40°C)

Operating humidity

10% – 80% relative humidity

Physical

Bench type

16.4 in (W) x 17.1 in (D) x 4.9 in (H)

 

41.7 cm (W) x 43.4 cm (D) x 12.4 cm (H)

 

17.6 lb (8.0 Kg)

Pole type

16.4 in (W) x 16.5 in (D) x 17.9 in (H)

 

41.7 cm (W) x 41.9 cm (D) x 45.5 cm (H)

 

19.4 lb (8.8 Kg)

Image 32
Contents DC-190 Introduction Repacking DC-190 Scale Capacities and ResolutionsUnpacking and Inspection Other S-Series Remote Platforms Scale no DC-190 ConsoleUW/1000 Pcs 2 DC-190 Keypad Locking and Unlocking InstallationSetting Up Powering Up the DC-190 Location of AC Power Cord Receptacle Load Cell CableSetting Time and Date Location of Top Cover ScrewsInstalling Cable Strain Relief Pole Mounting InstructionsSpec Scale SetupScale Configurations Spec SPEC17 APW Customer Specification 141 SettingsSwitching if Spec 2, bit 1 is set DIN-8 Force Balance 010 Weight and Measurement Specifications 142 Settings Connector, select SpecSpec Min Max Selecting 1 can damageLoad Cell Sensitivity Selection mV/V-PORT 2, Scale 2 or Max Spec MinRS-232 Specifications 143 Settings Not used set toEntering Tare Weights Scale OperationsToggle Between Scales Toggling Between Net and Gross WeightEntering Unit Weights Unit Weight Operation by Key Entry Other Operations Scale Programming Item Code StorageItem Code Maintenance Using Item Code in Normal Mode Re-Computing Item Code Unit Weight Procedure Connector Pinouts Pin DIN FemaleDC-190 Messages Clearing Locked-Up Scale 888888 Error 10.11 DC-190 Ultra Count Specifications DC-190 Ultra Count Limited Warranty