9. ADDITIONAL INFORMATION

This section describes the additional functions and corrections to the instruction manual of FS-iseries (WM+PD4001332 and 1WMPD4001368) which are common to the FS-D.

9-1. F-Function list

The following function settings are added (“11-2. Function list” in WM+PD4001332).

Item

Function number

Description

 

Serial interface

 

f06- 5

Multi-connection with print key mode

The UFC format

Data output

 

(RS-422/485)

 

 

mode

 

 

 

is applicable to

 

f06- 6

Auto-print mode + data & OK

 

f06-2 to 4.

 

 

f06- 7

Auto-print mode +/- data & OK

 

 

 

Zero tracking

 

f13- 0

Zero tracking OFF

Setting C04-0,

 

Š

f13- 1

Zero tracking ON, 0.5d/sec

 

f13-2 and 3

 

 

f13- 2

Zero tracking ON, 1.0d/sec

 

 

cannot be set.

 

 

f13- 3

Zero tracking ON, 2.0d/sec

 

 

 

Auto-tare

Š

f21- 0

Auto-tare function disabled.

 

function

 

f21- 1

Auto-tare function enabled.

 

Auto-tare timing

 

f22- 0

Immediately after OK and stable

 

 

 

f22- 1

0.5 sec. after OK and stable

Timing to tare

 

Š

f22- 2

1.0 sec. after OK and stable

 

 

 

 

automatically

 

 

f22- 3

1.5 sec. after OK and stable

 

 

after the comp.

 

 

f22- 4

2.0 sec. after OK and stable

 

 

OK and weight

 

 

f22- 5

2.5 sec. after OK and stable

 

 

stable.

 

 

f22- 6

3.0 sec. after OK and stable

 

 

To be used with

 

 

f22- 7

4.0 sec. after OK and stable

f21-1.

 

 

f22- 8

5.0 sec. after OK and stable

 

 

 

f22- 9

6.0 sec. after OK and stable

 

Auto-tare for the

Š

f23- 0

Function disabled

Automatic

initial weight

 

f23- 1

Tares the initial (container) weight.

operation.

Normal/Negative

Š

f24- 0

Normal comparison

 

comparison

 

f24- 1

Negative comparison for take-away

 

ŠFactory setting

9-2. OP-03 RS-232C

The followings are the corrections and the additional information for the optional interface (“2-2.OP-03 Specifications” and 2-3. Command Mode” in 1WMPD4001368).

Circuit diagram

4

Signal ground SG

4

Signal ground SG

5

Shield

5

Frame ground FG

6

Frame ground FG

6

Shield

 

15

 

 

Image 17
Contents Weighing Indicator This Manual and Marks Contents Classification of protection provided by enclosures ComplianceCompliance with FCC rules Introduction Unpacking Load Cell Connections Precautions for Installing the IndicatorExample of calculation Verifying Load Cell Output and Input SensitivityCalculating formula Parameter Settings and Calibration Setting Up the IndicatorNames and Functions Names Functions / Operation Comparison Indicators 00Cal00 C01-01 -C02-01 -C02-00-C02-02-C03-01-00end00 Function Parameter SettingsProcedure for setting parameters Function list Calibration Calibration using a weight00 Cal00 00Cal00Gravity acceleration correction Go to of 7-1. Calibration using a weight00end00 AUTO-TARE Function OP-03 RS-232C Circuit diagramAdditional Information Data format Data output mode f062-3. Command Mode OP-04 RS-422 Multi-connection with Print key mode new functionErr-# Error MessagesLb1 Capacity and minimum display SpecificationsSpecifications Options DimensionsPage German Sales Office UK OfficeKorea Limited Instruments India Private Limited