4. INSTALLATION and PRECAUTIONS

4-1. Precautions for Installing the Indicator

‰ Ground the indicator so that the user will not be subjected an electric shock.

‰ Do not handle the main power cord with wet hands.

‰ The AC plug is not water-resistant. Install it in an area where it does not get wet. ‰ Do not install the indicator where there is flammable or corrosive gas present.

‰Do not install the indicator under water.

‰Do not pull, fold or arrange cables forcibly.

‰Use shielded cables for all connections.

‰Ground the platform to be connected to the indicator to avoid a risk of electric shock.

Read the section “CAUTION” in the instruction manual of the FS-ito understand the conditions and precautions for installation, operation and cleaning the indicator.

4-2. Load Cell Connections

‰Solder the load cell cable to the connector plug (1JMNJW-165-PM7) provided with the FS-D and connect it to the connector on the bottom of the FS-D.

1.Use the supplied hexagonal wrench (1.27 mm / 0.05 inch) to loosen the setscrews A and B to disassemble the connector plug.

Connector plug (1JMNJW-165-PM7)

Load cell cable

Setscrew B

Setscrew A

Pin contacts

2.Put the load cell cable through each parts of the connector taking care of their order and directions.

3.Remove the sheath and wire covering of the load cell cable referring to the drawing below.

‰The external diameter of the applicable load cell cable is Ø5.7 ~ Ø6.8 mm.

Load cell cable

Ø5.7 ~ Ø6.8 mm

16 mm

3.2 mm

5

Image 7
Contents Weighing Indicator This Manual and Marks Contents Compliance with FCC rules ComplianceClassification of protection provided by enclosures Introduction Unpacking Load Cell Connections Precautions for Installing the IndicatorCalculating formula Verifying Load Cell Output and Input SensitivityExample of calculation Parameter Settings and Calibration Setting Up the IndicatorNames and Functions Names Functions / Operation Comparison Indicators Procedure for setting parameters Function Parameter Settings00Cal00 C01-01 -C02-01 -C02-00-C02-02-C03-01-00end00 Function list 00Cal00 Calibration using a weightCalibration 00 Cal0000end00 Go to of 7-1. Calibration using a weightGravity acceleration correction AUTO-TARE Function Additional Information Circuit diagramOP-03 RS-232C 2-3. Command Mode Data output mode f06Data format OP-04 RS-422 Multi-connection with Print key mode new functionLb1 Error MessagesErr-# Specifications SpecificationsCapacity and minimum display Options DimensionsPage Instruments India Private Limited UK OfficeGerman Sales Office Korea Limited