4.Solder the wires to the pin contacts of the connector. ‰ A 5 m or less load cell cable is recommended as the

FS-D uses a 4 wire system (no remote sensing).

Load cell cable

SIG-

Load cell connector

Load cell

5.Reassemble the connector plug and tighten the setscrew A.

6.Move the load cell cable back and forth and around, and tighten each parts again. Finally, tighten the setscrew B.

7.Connect the connector plug to the load cell connector on the bottom of the display pod.

EXC+

SIG+

EXC-

Shield

Setscrew B

Setscrew A

4-3. Verifying Load Cell Output and Input Sensitivity

The input sensitivity is 0.2 µV/division or more. When designing a weighing scale, the load cell output voltage should satisfy the input sensitivity of the indicator. Or the scale should be designed so that the following calculating formula is satisfied.

‰In order to achieve a scale with stable performance, select the input sensitivity as large as possible.

Calculating formula:

0.2E B d A n

A : Rated capacity of load cell (kg)

B : Rated output (mV/V)

d: Min. display (smallest of kg) / scale division E : Excitation voltage (mV) = 5000 mV for FS-D n : Number of load cells

Example of calculation:

In the case of designing a scale with a capacity of 60 kg, using a load cell with a rated capacity of 100 kg and rated output of 1 mV/V:

Load cell capacity:

A = 100 kg

Rated output:

B = 1 mV/V

Set function setting C02-3, then

d = 0.005 kg

Min. display (smallest):

Excitation voltage:

E = 5000 mV

Number of load cell:

n = 1

 

6

5000 ⋅1⋅ 0.005

= 0.25 > 0.2

100 ⋅1

 

Image 8
Contents Weighing Indicator This Manual and Marks Contents Classification of protection provided by enclosures ComplianceCompliance with FCC rules Introduction Unpacking Precautions for Installing the Indicator Load Cell ConnectionsExample of calculation Verifying Load Cell Output and Input SensitivityCalculating formula Setting Up the Indicator Parameter Settings and CalibrationNames and Functions Names Functions / Operation Comparison Indicators 00Cal00 C01-01 -C02-01 -C02-00-C02-02-C03-01-00end00 Function Parameter SettingsProcedure for setting parameters Function list Calibration using a weight Calibration00 Cal00 00Cal00Gravity acceleration correction Go to of 7-1. Calibration using a weight00end00 AUTO-TARE Function OP-03 RS-232C Circuit diagramAdditional Information Data format Data output mode f062-3. Command Mode Multi-connection with Print key mode new function OP-04 RS-422Err-# Error MessagesLb1 Capacity and minimum display SpecificationsSpecifications Dimensions OptionsPage UK Office German Sales OfficeKorea Limited Instruments India Private Limited