A&D SW-150KL, SW-6KS, SW-30KM, SW-60KL, SW-60KM, SW-150KM, SW-15KM, SW-15KS manual Solid sate relay

Page 31

Circuit diagram

1 Receive data RXD

2 Transmit data TXD

3 Data set ready DSR

4 Signal ground SG

5 Shield SHLD

‰SW is designed as DCE (Data Communication Equipment).

LOLO

 

LO

 

OK

 

HI

 

HIHI

 

Solid sate relay

SW inside

1Relay output LOLO

2Relay output LO

3Relay output OK

4Relay output HI

5Relay output HIHI

6Relay common COM

7Shield SHLD

Data format

S T

,

+ 0 0 0 0 0

.

0 0 _ k g CR

LF

Header

Data

Unit Terminator

‰There are 4 headers for the weighing data.

ST: Stable weighing data

QT: Stable counting data

US: Unstable weighing data

OL: Out of weighing range

‰The data consists of 9 characters including the polarity and decimal point.

‰There are 5 units.

_ k g: Weighing mode “kg”

_ _ g: Weighing mode “g”

_ l b: Weighing mode “lb”

_ o z: Weighing mode “oz”

_ PC: Counting mode “pcs”

‰As a terminator, CRLF is always output.

29

Image 31
Contents SW Series Page Contents Gravity Acceleration MAP MaintenanceSpecifications OptionsCompliance with FCC rules ComplianceClassification of protection provided by enclosures Introduction FeaturesOperating the scale PrecautionsInstalling the scale Cleaning the scaleUnpacking Display rear side Description of Each PartDisplay Display and symbolsSymbols Symbol DescriptionSwitches Attaching the display pole to the base Setting UPSW-M / L series with a display pole Installing the scale ON/OFF Turning the power on and OFFBasic Operation Bat ooDuring the Tare operation Indicator will not turn onSelecting a weighing unit Basic weighing operationWeight display resolution Print Counting ModeLolo Five-level comparator modeComparator Formula to compareThree-level comparator mode Entering the comparator values Five-level comparator mode Three-level comparator modePrint Sample Tare Gravity acceleration correction CalibrationUnits Print Calibration using a weightRestoring the factory set values Functions Setting the parametersTare ON/OFF Function list Key Installing the battery Using the OP-02 SLA batteryOptions Charging the battery OP-03 RS-232C / Relay Output Installing OP-03Ascii OP-03 SpecificationsSolid sate relay ‰ Data example Command mode Stable positive data Page OP-04 RS-422 Installing OP-04OP-04 Specifications Example of connection RS-422 Stable data Error codes MaintenanceSpecifications SpecificationsModel SW-6KS SW-15KS SW-15KM SW-30KM SW-60KL Model SW-60KMExternal dimensions SW-60KL / SW-150KL with a display pole Values of gravity at various locations Gravity Acceleration MAPWorld map