7.2.Installing the scale

1.Select the place for installing the scale. Refer to “4. PRECAUTIONS”.

2. Adjust the level of the base, using the spirit level and leveling feet. Confirm that the bubble is in the center of the level.

SW type with a display pole has an extra foot at the bottom of the pole. Adjust this foot to touch the floor after adjusting the level of the base.

Leveling foot

Spirit level

The size and shape depends on the scale model.

3. Adjust the display angle as follows.

 

Type with a display pole

 

(1)

Rotate the two display knobs

 

 

located on the display rear to

 

 

remove them.

 

(2)

Tilt the display to an appropriate

 

 

angle, 0°, 30°, 60° or 90°.

Display

(3)

Attach the two display knobs and

 

 

secure them firmly.

 

Display knobs

Type with a display stand

(1)Loosen the two display knobs located on the sides of the display.

(2)

Tilt the display to an appropriate

 

 

angle. (Free setting angle)

Display

 

 

(3)

Tighten the two display knobs.

 

Display knobs

4.Confirm that nothing is touching the switches and connect the AC power cable to an electrical outlet.

11

Image 13
Contents SW Series Page Contents Specifications MaintenanceOptions Gravity Acceleration MAPCompliance with FCC rules ComplianceClassification of protection provided by enclosures Introduction FeaturesInstalling the scale PrecautionsCleaning the scale Operating the scaleUnpacking Display rear side Description of Each PartSymbols Display and symbolsSymbol Description DisplaySwitches Attaching the display pole to the base Setting UPSW-M / L series with a display pole Installing the scale Basic Operation Turning the power on and OFFBat oo ON/OFFSelecting a weighing unit Indicator will not turn onBasic weighing operation During the Tare operationWeight display resolution Print Counting ModeComparator Five-level comparator modeFormula to compare LoloThree-level comparator mode Entering the comparator values Five-level comparator mode Three-level comparator modePrint Sample Tare Gravity acceleration correction CalibrationUnits Print Calibration using a weightRestoring the factory set values Functions Setting the parametersTare ON/OFF Function list Key Installing the battery Using the OP-02 SLA batteryOptions Charging the battery OP-03 RS-232C / Relay Output Installing OP-03Ascii OP-03 SpecificationsSolid sate relay ‰ Data example Command mode Stable positive data Page OP-04 RS-422 Installing OP-04OP-04 Specifications Example of connection RS-422 Stable data Error codes MaintenanceSpecifications SpecificationsModel SW-6KS SW-15KS SW-15KM SW-30KM SW-60KL Model SW-60KMExternal dimensions SW-60KL / SW-150KL with a display pole Values of gravity at various locations Gravity Acceleration MAPWorld map