Lifescan Diabetes Monitoring System manual Getting a Drop of Blood

Page 29

Getting a Drop of Blood

CAUTION: To reduce the chance of infection:

Never share a lancet with another person.

Always use a new, sterile LifeScan Lancet. Lancets are for single use only.

The PenletPlus Sampler should be used by only one person.

Avoid getting hand lotion, oils, dirt, or debris in or on the lancets and the Penlet Plus Sampler.

Step 1: Insert a Lancet into the PenletPlus Adjustable Blood Sampler.

Remove the PenletPlus Cap by twisting it counterclockwise. Insert a lancet into the lancet holder. Push down firmly until the lancet is fully seated in the holder. Do not twist the lancet. To avoid contamination and to prevent the cap from rolling away, set the cap down on a flat surface with its small hole pointing up.

22

Image 29
Contents Owner’s Booklet Dear ONE Touch TM Basic TM Plus Owner Page Page Table of Contents Using the Meter Memory Solving Problems Precautions and Limitations Infection Control Getting Started Page Button ONE Touch Basic Plus Blood Glucose MeterPage ONE Touch Test Strips Important Test Strip Information Setting Meter Code Before TestingMatch the Code Numbers Press the On/Off ButtonCode the Meter Checking the SystemChecking with the Check Strip Press the On/Off Button. Insert Side 1 of the Check Strip When insert code 10 ExampleStep Appears, Remove the Check Strip from the Test Strip HolderExample Checking with Control Solution Page Important Control Solution Test Information Press On/Off Button. Insert Test Strip When insert code10Control Solution Result Appears in 45 Seconds Apply Control SolutionControl solution results Penlet Plus Adjustable Blood Sampler Detailed Test ProcedureGetting a Drop of Blood Page Wash Your Hands Cock the Penlet Plus SamplerRemove the Lancet Lance Your FingerAlways use caution when removing Check code and then Remove a test strip Apply Blood Sample Accurate Results in 45 Seconds Special Messages Checking the Amount of Blood on the Test Strip Page Using the Meter Memory Entering the Memory Mode Recalling Test Results Entering and Using the Set-Up Mode Setting Meter OptionsPage Clock Time and Date Setting the Time Beep Prompts Language Date Format Time FormatDecimal Separator Unit of MeasureExiting the Set-Up Mode Code Solving ProblemsTest Procedure Messages Insert Code 1 0 Example Strip wait Apply sample Check codeInsert s i d e Alternating with Error Messages Battry Remove strip Clean test areaError 2 retest Error 1 retestMessage Problem What to do Not enough blood retest Error3 retestT o k Retest D o aMeter requires a Taking Care Your Meter Doing a Daily Check Cleaning the MeterRemove the Test Strip Holder from the Meter Clean the Test Strip HolderDo not USE Clean the Test AreaReplace the Test Strip Holder Replacing the Batteries To replace the batteries References Result Range 0-600 mg/dL SpecificationsThree-Year Warranty WarrantyPage Page IFD/OB/OTBP