Lifescan Diabetes Monitoring System manual Solving Problems, Test Procedure Messages, Code

Page 53

SOLVING PROBLEMS

The messages that appear on your ONE TOUCHBASICPlus Meter display guide you through the testing procedure, alert you to problems as they occur, and give you information about test results stored in the meter’s memory. This section provides you with a complete listing of the display messages, what they mean, and what to do if there is a problem.

Test Procedure Messages

These messages appear during routine testing. Follow them carefully and they will guide you through the test.

MESSAGE

APPEARS WHEN

 

Appears briefly when the meter is turned on. You

 

can see that all of the display segments are working

 

properly.

code--

The meter is turned on and you have not previous-

ly coded the meter. This is a reminder that you

 

 

should verify that the code displayed on the meter

 

matches the code on the test strip vial before test-

 

ing. If it does not, reset by pressing the C button.

46

Image 53
Contents Owner’s Booklet Dear ONE Touch TM Basic TM Plus Owner Page Page Table of Contents Using the Meter Memory Solving Problems Precautions and Limitations Infection Control Getting Started Page Button ONE Touch Basic Plus Blood Glucose MeterPage ONE Touch Test Strips Important Test Strip Information Setting Meter Code Before TestingMatch the Code Numbers Press the On/Off ButtonCode the Meter Checking the SystemChecking with the Check Strip Press the On/Off Button. Insert Side 1 of the Check Strip When insert code 10 ExampleStep Appears, Remove the Check Strip from the Test Strip HolderExample Checking with Control Solution Page Important Control Solution Test Information Press On/Off Button. Insert Test Strip When insert code10Control Solution Result Appears in 45 Seconds Apply Control SolutionControl solution results Penlet Plus Adjustable Blood Sampler Detailed Test ProcedureGetting a Drop of Blood Page Wash Your Hands Cock the Penlet Plus SamplerRemove the Lancet Lance Your FingerAlways use caution when removing Check code and then Remove a test strip Apply Blood Sample Accurate Results in 45 Seconds Special Messages Checking the Amount of Blood on the Test Strip Page Using the Meter Memory Entering the Memory Mode Recalling Test Results Entering and Using the Set-Up Mode Setting Meter OptionsPage Clock Time and Date Setting the Time Beep Prompts Language Date Format Time FormatDecimal Separator Unit of MeasureExiting the Set-Up Mode Code Solving ProblemsTest Procedure Messages Insert Code 1 0 Example Strip wait Apply sample Check codeInsert s i d e Alternating with Error Messages Battry Remove strip Clean test areaError 2 retest Error 1 retestMessage Problem What to do Not enough blood retest Error3 retestT o k Retest D o aMeter requires a Taking Care Your Meter Doing a Daily Check Cleaning the MeterRemove the Test Strip Holder from the Meter Clean the Test Strip HolderDo not USE Clean the Test AreaReplace the Test Strip Holder Replacing the Batteries To replace the batteries References Result Range 0-600 mg/dL SpecificationsThree-Year Warranty WarrantyPage Page IFD/OB/OTBP