Genie GR-15, GR-20, GR-12 manual Pre-operation Inspection, PRE-OPERATION Inspection

Page 15

Third Edition • Second Printing

Operator's Manual

 

 

 

 

Pre-operation Inspection

oBe sure that the operator's, safety and responsibilities manuals are complete, legible and in the storage container located on the platform.

oBe sure that all decals are legible and in place. See Decals section.

oCheck for hydraulic oil leaks and proper oil level. See Maintenance section.

oCheck for battery fluid leaks and proper fluid level. Add distilled water if needed. See Maintenance section.

Check the following components or areas for damage, improperly installed or missing parts and unauthorized modifications:

oElectrical components, wiring and electrical cables

oHydraulic power unit, tank, hoses, fittings, cylinders and manifolds

oBattery pack and connections

oDrive motors

oTires and wheels

oLimit switches and alarms

oNuts, bolts and other fasteners

oPlatform entry mid-rail bar or gate

oSequencing cables and pulleys

oPlatform extension (if equipped)

oWork trays and bike racks (if equipped)

oMast columns and counterweight

oPlatform controls

oBrake release components

PRE-OPERATION INSPECTION

Check the entire machine for:

oCracks in welds or structural components

oDents or damage to the machine

oBe sure that all structural and other critical components are present and all associated fasteners and pins are in place and properly tightened.

Part No. 97779

GR-12GR-15GR-20

13

Image 15
Contents Operator’s Manual Contact us ContentsDo Not Operate Unless Safety RulesAWP and fiberglass platform Electrocution HazardsMaximum capacity GR-12 and GR-15 Standard platform Stock Picker platformMaximum capacity GR-20 Standard platform Maximum slope rating, stowed positionMaximum side slope rating Stowed position Maximum allowable manual force Collision Hazards Fall HazardsDamaged Machine Hazards Crushing HazardComponent Damage Hazard Explosion and Fire HazardLifting Hazard Battery Safety Burn HazardsExplosion Hazards Tip-over HazardDecal Legend Page Platform Controls ControlsGround Control Panel Fundamentals Pre-operation InspectionPRE-OPERATION Inspection Pre-operation InspectionObserve and Obey MaintenanceMaintenance Symbols Legend Hydraulic oil specificationsCheck the Batteries Scheduled MaintenanceFunction Tests At the Platform Controls At the Ground ControlsTest the Steering Test Drive and BrakingTest the Tilt Sensor Operation Test the Pothole Guards Test Limited Drive SpeedWorkplace Inspection Workplace InspectionOnly use the machine as it was intended Operating InstructionsOperation From Platform Emergency StopAuxiliary Lowering Operation From GroundDriving on a slope To Reduce Drive SpeedOperation From Ground with Controller Error Indicator displayBattery Level Indicator To Extend and Retract Platform if equippedStandard Batteries Battery and Charger Instructions Observe and ObeyMaintenance free batteries To Charge BatteriesBrake Release Operation Transport and Lifting InstructionsLoading the Machine With a Crane Securing to Truck or Trailer for TransitSecuring the Chassis Description Quantity DecalsDecals Inspection for Decals with Symbols Stock Picker Platform Decals Floor loading information SpecificationsGR-12 Drive speedsGR-15 SpecificationsGR-20 Platform dimensions, all models length x width Genie Scandinavia