Genie Fault Code List & Troubleshooting Guide for GR Series Models

Page 26

Operator's Manual

Third Edition • Second Printing

 

 

 

 

OPERATING INSTRUCTIONS

Error Indicator display

If the LED diagnostic readout displays an error code, such as LL, push in and pull out the red Emergency Stop button to reset the system.

To Extend and Retract Platform (if equipped)

1Step on the platform extension release pedal.

2Grasp the platform guard rails carefully and push to extend the platform.

3Step on the platform extension release pedal and pull the guard rails to retract the platform.

Operation From Ground with Controller

Maintain safe distances between the operator, machine and fixed objects.

Be aware of the direction the machine will travel when using the controller.

Platform Overload

Flashing OL in the LED diagnostic readout indicates the platform is overloaded and no functions will operate. An alarm will sound.

1Push in the Red Emergency stop button to the off position.

2Remove the weight from the platform.

3Pull out the Red Emergency stop button to the on position.

Battery Level Indicator

FullLow

Use the LED diagnostic readout to determine the battery level.

Fall Protection

Personal fall protection equipment (PFPE) is not required when operating this machine. If PFPE is required by job site or employer rules, the following shall apply:

All PFPE must comply with applicable governmental regulations and must be inspected and used in accordance with the manufacturer’s instructions.

After Each Use

1Select a safe parking location—firm level surface, clear of obstruction and traffic.

2Lower the platform.

3Turn the key switch to the off position and remove the key to secure from unauthorized use.

4Chock the wheels.

5Charge the batteries.

24

GR-12GR-15GR-20

Part No. 97779

Image 26
Contents Operator’s Manual Contents Contact usSafety Rules Do Not Operate UnlessStock Picker platform Electrocution HazardsMaximum capacity GR-12 and GR-15 Standard platform AWP and fiberglass platformMaximum side slope rating Stowed position Maximum capacity GR-20 Standard platformMaximum slope rating, stowed position Maximum allowable manual force Fall Hazards Collision HazardsExplosion and Fire Hazard Crushing HazardComponent Damage Hazard Damaged Machine HazardsTip-over Hazard Battery Safety Burn HazardsExplosion Hazards Lifting HazardDecal Legend Page Controls Platform ControlsGround Control Panel Pre-operation Inspection FundamentalsPre-operation Inspection PRE-OPERATION InspectionHydraulic oil specifications MaintenanceMaintenance Symbols Legend Observe and ObeyScheduled Maintenance Check the BatteriesFunction Tests At the Ground Controls At the Platform ControlsTest the Tilt Sensor Operation Test the SteeringTest Drive and Braking Test Limited Drive Speed Test the Pothole GuardsWorkplace Inspection Workplace InspectionOperating Instructions Only use the machine as it was intendedOperation From Ground Emergency StopAuxiliary Lowering Operation From PlatformTo Reduce Drive Speed Driving on a slopeTo Extend and Retract Platform if equipped Error Indicator displayBattery Level Indicator Operation From Ground with ControllerTo Charge Batteries Battery and Charger Instructions Observe and ObeyMaintenance free batteries Standard BatteriesTransport and Lifting Instructions Brake Release OperationSecuring the Chassis Loading the Machine With a CraneSecuring to Truck or Trailer for Transit Decals Description QuantityDecals Inspection for Decals with Symbols Stock Picker Platform Decals Drive speeds SpecificationsGR-12 Floor loading informationSpecifications GR-15GR-20 Platform dimensions, all models length x width Genie Scandinavia