Genie GR-20 manual Electrocution Hazards, Maximum capacity GR-12 and GR-15 Standard platform

Page 4

Operator's Manual

Third Edition • Second Printing

 

 

 

 

SAFETY RULES

Electrocution Hazards

Tip-over Hazards

This machine is not electrically insulated and will not provide protection from contact with or proximity to electrical current.

Maintain safe distances from electrical power lines and apparatus in accordance with applicable governmental regulations and the following chart.

Voltage

Minimum Safe

Phase to Phase

Approach Distance

 

Meters

 

 

0 to 300V

Avoid Contact

 

 

300V to 50KV

3.05

 

 

50KV to 200KV

4.60

 

 

200KV to 350KV

6.10

 

 

350KV to 500KV

7.62

 

 

500KV to 750KV

10.67

 

 

750KV to 1000KV

13.72

 

 

Allow for platform movement, electrical line sway or sag and beware of strong or gusty winds.

Keep away from the machine if it contacts energized power lines. Personnel on the ground or in the platform must not touch or operate the machine until energized power lines are shut off.

Do not operate the machine during lightning or storms.

Do not use the machine as a ground for welding.

Occupants, equipment and materials must not exceed the maximum platform capacity. Weight in trays and in each bike rack is part of the total platform load.

Maximum capacity - GR-12 and GR-15

Standard platform

227 kg

 

 

Work station tray (option)

22 kg

 

 

Parcel tray (option)

68 kg

 

 

Maximum occupants

1

 

 

Stock Picker platform

227 kg

 

 

Adjustable work station tray

68 kg

 

 

Parcel tray (option)

68 kg

 

 

Bike rack (option) (each)

20 kg

 

 

Maximum occupants

1

 

 

AWP and fiberglass platform

159 kg

 

 

Maximum occupants

1

 

 

2

GR-12GR-15GR-20

Part No. 97779

Image 4
Contents Operator’s Manual Contents Contact usSafety Rules Do Not Operate UnlessElectrocution Hazards Maximum capacity GR-12 and GR-15 Standard platformStock Picker platform AWP and fiberglass platformMaximum slope rating, stowed position Maximum capacity GR-20 Standard platformMaximum side slope rating Stowed position Maximum allowable manual force Fall Hazards Collision HazardsCrushing Hazard Component Damage HazardExplosion and Fire Hazard Damaged Machine HazardsBattery Safety Burn Hazards Explosion HazardsTip-over Hazard Lifting HazardDecal Legend Page Controls Platform ControlsGround Control Panel Pre-operation Inspection FundamentalsPre-operation Inspection PRE-OPERATION InspectionMaintenance Maintenance Symbols LegendHydraulic oil specifications Observe and ObeyScheduled Maintenance Check the BatteriesFunction Tests At the Ground Controls At the Platform ControlsTest Drive and Braking Test the SteeringTest the Tilt Sensor Operation Test Limited Drive Speed Test the Pothole GuardsWorkplace Inspection Workplace InspectionOperating Instructions Only use the machine as it was intendedEmergency Stop Auxiliary LoweringOperation From Ground Operation From PlatformTo Reduce Drive Speed Driving on a slopeError Indicator display Battery Level IndicatorTo Extend and Retract Platform if equipped Operation From Ground with ControllerBattery and Charger Instructions Observe and Obey Maintenance free batteriesTo Charge Batteries Standard BatteriesTransport and Lifting Instructions Brake Release OperationSecuring to Truck or Trailer for Transit Loading the Machine With a CraneSecuring the Chassis Decals Description QuantityDecals Inspection for Decals with Symbols Stock Picker Platform Decals Specifications GR-12Drive speeds Floor loading informationSpecifications GR-15GR-20 Platform dimensions, all models length x width Genie Scandinavia