Operator's Manual

 

 

 

 

1Select a test area that is firm, level and free of obstruction.

2Be sure the battery pack is connected.

At the Ground Controls

3Pull out the platform and ground red Emergency Stop buttons to the on position.

4Turn the key switch to ground control.

5Observe the diagnostic LED readout on the platform controls.

Result: The LED should look like the picture at right.

Test Emergency Stop

6Push in the ground red Emergency Stop button to the off position.

Result: No functions should operate.

7Pull out the red Emergency Stop button to the on position.

Test the Up/Down Functions

8 Activate the up function.

Result: The platform should raise.

9 Activate the down function.

Result: The platform should lower. The descent alarm should sound while the platform is lowering.

Test Manual Lowering

10 Activate the up function and raise the platform approximately 60 cm.

11Pull the manual lowering knob located at the base of the machine below the charger.

Result: The platform should lower. The descent alarm will not sound.

12 Turn the key switch to platform control.

FUNCTION TESTS

At the Platform Controls

Test Emergency Stop

13Push in the platform red Emergency Stop button to the off position.

Result: No functions should operate.

Test the Horn

14Pull out the red Emergency Stop button to the on position.

15Push the horn button.

Result: The horn should sound.

Test the Function Enable Switch

16Do not press the function enable switch on the control handle.

17Slowly move the control handle in the direction indicated by the blue arrow, then in the direction indicated by the yellow arrow.

Result: No functions should operate.

Test the Up/Down Functions

18 Press the lift function select button.

19 Press and hold the function enable switch on the control handle.

20Slowly move the control handle in the direction indicated by the blue arrow.

Result: The platform should raise.

21 Release the control handle.

Result: The platform should stop raising.

Part No. 97779

GR-12GR-15GR-20

17

Image 19
Contents Operator’s Manual Contact us ContentsDo Not Operate Unless Safety RulesAWP and fiberglass platform Electrocution HazardsMaximum capacity GR-12 and GR-15 Standard platform Stock Picker platformMaximum slope rating, stowed position Maximum capacity GR-20 Standard platformMaximum side slope rating Stowed position Maximum allowable manual force Collision Hazards Fall HazardsDamaged Machine Hazards Crushing HazardComponent Damage Hazard Explosion and Fire HazardLifting Hazard Battery Safety Burn HazardsExplosion Hazards Tip-over HazardDecal Legend Page Platform Controls ControlsGround Control Panel Fundamentals Pre-operation InspectionPRE-OPERATION Inspection Pre-operation Inspection Observe and Obey Maintenance Maintenance Symbols Legend Hydraulic oil specificationsCheck the Batteries Scheduled MaintenanceFunction Tests At the Platform Controls At the Ground ControlsTest Drive and Braking Test the SteeringTest the Tilt Sensor Operation Test the Pothole Guards Test Limited Drive SpeedWorkplace Inspection Workplace InspectionOnly use the machine as it was intended Operating InstructionsOperation From Platform Emergency StopAuxiliary Lowering Operation From GroundDriving on a slope To Reduce Drive SpeedOperation From Ground with Controller Error Indicator displayBattery Level Indicator To Extend and Retract Platform if equippedStandard Batteries Battery and Charger Instructions Observe and ObeyMaintenance free batteries To Charge BatteriesBrake Release Operation Transport and Lifting InstructionsSecuring to Truck or Trailer for Transit Loading the Machine With a CraneSecuring the Chassis Description Quantity DecalsDecals Inspection for Decals with Symbols Stock Picker Platform Decals Floor loading information SpecificationsGR-12 Drive speedsGR-15 SpecificationsGR-20 Platform dimensions, all models length x width Genie Scandinavia